Mohawk Hydro Corporation; Notice of Application Tendered for Filing With the Commission and Soliciting Additional Study Requests, 68427-68429 [2014-27054]
Download as PDF
68427
Federal Register / Vol. 79, No. 221 / Monday, November 17, 2014 / Notices
FERC–725D, MODIFICATIONS IN RD14–12
Number and type of
respondent 6
Annual
number of
responses per
respondent
Total number
of responses
Average
burden per
response
(hours)
Total annual
burden
(hours)
Total annual
cost 7
(1)
(2)
(1)*(2) = (3)
(4)
(3)*(4) = (5)
($)
FAC–001–2
Documentation & updates ..
Record Retention ................
GO 5 ...................................
TO 332 ...............................
GO 5 ...................................
TO 332 ...............................
1
1
1
1
5
332
5
332
16
16
1
1
80
5312
5
332
$5,833.60
387,351.04
145.05
9,631.32
FAC–002–2
Study ...................................
Record Retention ................
Coordination ........................
Record Retention ................
Total .............................
PC,
PC,
TO,
TO,
TP 183 ........................
TP 183 ........................
DP, LSE, GO 216 .......
DP, LSE, GO 216 .......
1
1
1
1
183
183
216
216
32
1
16
1
5856
183
3456
216
427,019. 52
5,308.83
252,011.52
6,266.16
.............................................
........................
........................
........................
........................
1,093,567.04
The total estimated annual burden
cost to respondents is: $1,093,567.04.
Dated: November 7, 2014.
Kimberly D. Bose,
Secretary.
[FR Doc. 2014–27055 Filed 11–14–14; 8:45 am]
BILLING CODE 6717–01–P
DEPARTMENT OF ENERGY
Federal Energy Regulatory
Commission
[Project No. 12636–002]
asabaliauskas on DSK5VPTVN1PROD with NOTICES
Mohawk Hydro Corporation; Notice of
Application Tendered for Filing With
the Commission and Soliciting
Additional Study Requests
Take notice that the following
hydroelectric application has been filed
with the Commission and is available
for public inspection.
a. Type of Application: Original Major
License
b. Project No.: 12636–002
c. Date filed: October 24, 2014
d. Applicant: Mohawk Hydro
Corporation
e. Name of Project: Middle Mohawk
Hydroelectric Project
f. Location: The project would be
located on the Mohawk River, in
Schenectady and Montgomery Counties,
New York.
g. Filed Pursuant to: Federal Power
Act 16 U.S.C. 791(a)–825(r).
h. Applicant Contact: Wendy Jo
Carey, Mohawk Hydro Corporation, 5
Washington Square, Albany, NY 12205;
or at (518) 456–7712.
i. FERC Contact: Monir Chowdhury,
(202) 502–6736 or monir.chowdhury@
ferc.gov
VerDate Sep<11>2014
17:14 Nov 14, 2014
Jkt 235001
j. Cooperating agencies: Federal, state,
local, and tribal agencies with
jurisdiction and/or special expertise
with respect to environmental issues
that wish to cooperate in the
preparation of the environmental
document should follow the
instructions for filing such requests
described in item l below. Cooperating
agencies should note the Commission’s
policy that agencies that cooperate in
the preparation of the environmental
document cannot also intervene. See, 94
FERC ¶ 61,076 (2001).
k. Pursuant to section 4.32(b)(7) of 18
CFR of the Commission’s regulations, if
any resource agency, Indian Tribe, or
person believes that an additional
scientific study should be conducted in
order to form an adequate factual basis
for a complete analysis of the
application on its merit, the resource
agency, Indian Tribe, or person must file
a request for a study with the
Commission not later than 60 days from
the date of filing of the application, and
serve a copy of the request on the
applicant.
l. Deadline for filing additional study
requests and requests for cooperating
agency status: December 23, 2014.
The Commission strongly encourages
electronic filing. Please file additional
study requests and requests for
cooperating agency status using the
Commission’s eFiling system at https://
www.ferc.gov/docs-filing/efiling.asp. For
assistance, please contact FERC Online
Support at FERCOnlineSupport@
ferc.gov, (866) 208–3676 (toll free), or
(202) 502–8659 (TTY). In lieu of
electronic filing, please send a paper
copy to: Secretary, Federal Energy
Regulatory Commission, 888 First Street
NE., Washington, DC 20426. The first
PO 00000
Frm 00023
Fmt 4703
Sfmt 4703
page of any filing should include docket
number P–12636–002.
m. The application is not ready for
environmental analysis at this time.
n. The proposed project would be
located at eight existing lock and dam
facilities (Lock Numbers: E8 through
E15) that are owned by the New York
State Canal Corporation. The proposed
run-of-river project would consist of the
following eight developments:
Lock E8 Scotia Development would
consist of: (1) An existing 530-foot-long,
14-foot-high bridge type dam; (2) an
existing 336-acre impoundment at an
elevation of 223.44 feet North Atlantic
Vertical Datum of 1988 (NAVD 88); (3)
two new identical modular steel
transportable barges, with each barge
resting on a foundation consisting of
four steel reinforced concrete pylons
and consisting of: (a) A steel intake
structure approximately 130 feet long by
40 feet wide by 15 feet high and (b) an
approximately 130-foot-long by 40-footwide by 10-foot-high steel powerhouse
containing nine turbine-generator units
having a capacity of 220 kilowatts (kW)
each; (4) a new short transmission line
connecting a new transportable 40-footlong by 8-foot-wide by 8-foot-high grid
interface unit to an existing 34.5kilovolt (kV) or lower voltage grid
distribution or sub-transmission line;
and (5) appurtenant facilities. The
development would have an annual
generation of 15,473 megawatt-hours
(MWh).
Lock E9 Rotterdam Junction
Development would consist of: (1) An
existing 530-foot-long, 15-foot-high
bridge type dam; (2) an existing 428-acre
impoundment at an elevation of 238.78
feet NAVD 88; (3) two new identical
modular steel transportable barges, with
E:\FR\FM\17NON1.SGM
17NON1
asabaliauskas on DSK5VPTVN1PROD with NOTICES
68428
Federal Register / Vol. 79, No. 221 / Monday, November 17, 2014 / Notices
each barge resting on a foundation
consisting of four steel reinforced
concrete pylons and consisting of: (a) A
steel intake structure approximately 130
feet long by 40 feet wide by 15 feet high
and (b) an approximately 130-foot-long
by 40-foot-wide by 10-foot-high steel
powerhouse containing nine turbinegenerator units having a capacity of 220
kW each; (4) a new short transmission
line connecting a new transportable 40foot-long by 8-foot-wide by 8-foot-high
grid interface unit to an existing 34.5-kV
or lower voltage grid distribution or subtransmission line; and (5) appurtenant
facilities. The development would have
an annual generation of 16,440 MWh.
Lock E10 Cranesville Development
would consist of: (1) An existing 500foot-long, 15-foot-high bridge type dam;
(2) an existing 414-acre impoundment at
an elevation of 253.37 feet NAVD 88; (3)
two new identical modular steel
transportable barges, with each barge
resting on a foundation consisting of
four steel reinforced concrete pylons
and consisting of: (a) A steel intake
structure approximately 130 feet long by
40 feet wide by 15 feet high and (b) an
approximately 130-foot-long by 40-footwide by 10-foot-high steel powerhouse
containing nine turbine-generator units
having a capacity of 220 kilowatts each;
(4) a new short transmission line
connecting a new transportable 40-footlong by 8-foot-wide by 8-foot-high grid
interface unit to an existing 34.5-kV or
lower voltage grid distribution or subtransmission line; and (5) appurtenant
facilities. The development would have
an annual generation of 16,296 MWh.
Lock E11 Amsterdam Development
would consist of: (1) An existing 588foot-long, 12-foot-high bridge type dam;
(2) an existing 414-acre impoundment at
an elevation of 265.44 feet NAVD 88; (3)
two new identical modular steel
transportable barges, with each barge
resting on a foundation consisting of
four steel reinforced concrete pylons
and consisting of: (a) A steel intake
structure approximately 130 feet long by
40 feet wide by 15 feet high and (b) an
approximately 130-foot-long by 40-footwide by 10-foot-high steel powerhouse
containing nine turbine-generator units
having a capacity of 220 kilowatts each;
(4) a new short transmission line
connecting a new transportable 40-footlong by 8-foot-wide by 8-foot-high grid
interface unit to an existing 34.5-kV or
lower voltage grid distribution or subtransmission line; and (5) appurtenant
facilities. The development would have
an annual generation of 12,461 MWh.
Lock E12 Tribes Hill Development
would consist of: (1) An existing 460foot-long, 11-foot-high bridge type dam;
(2) an existing 737-acre impoundment at
an elevation of 276.52 feet NAVD 88; (3)
two new identical modular steel
transportable barges, with each barge
resting on a foundation consisting of
four steel reinforced concrete pylons
and consisting of: (a) A steel intake
structure approximately 130 feet long by
40 feet wide by 15 feet high and (b) an
approximately 130-foot-long by 40-footwide by 10-foot-high steel powerhouse
containing nine turbine-generator units
having a capacity of 220 kilowatts each;
(4) a new short transmission line
connecting a new transportable 40-footlong by 8-foot-wide by 8-foot-high grid
interface unit to an existing 34.5-kV or
lower voltage grid distribution or subtransmission line; and (5) appurtenant
facilities. The development would have
an annual generation of 11,266 MWh.
Lock E13 Randall Development would
consist of: (1) An existing 370-foot-long,
8-foot-high bridge type dam; (2) an
existing 464-acre impoundment at an
elevation of 284.52 feet NAVD 88; (3)
two new identical modular steel
transportable barges, with each barge
resting on a foundation consisting of
four steel reinforced concrete pylons
and consisting of: (a) A steel intake
structure approximately 130 feet long by
40 feet wide by 15 feet high and (b) an
approximately 130-foot-long by 40-footwide by 10-foot-high steel powerhouse
containing nine turbine-generator units
having a capacity of 220 kilowatts each;
(4) a new short transmission line
connecting a new transportable 40-footlong by 8-foot-wide by 8-foot-high grid
interface unit to an existing 34.5-kV or
lower voltage grid distribution or subtransmission line; and (5) appurtenant
facilities. The development would have
an annual generation of 7,734 MWh.
Lock E14 Canajoharie Development
would consist of: (1) An existing 430foot-long, 8-foot-high bridge type dam;
(2) an existing 219-acre impoundment at
an elevation of 292.38 feet NAVD 88; (3)
two new identical modular steel
transportable barges, with each barge
resting on a foundation consisting of
four steel reinforced concrete pylons
and consisting of: (a) A steel intake
structure approximately 130 feet long by
40 feet wide by 15 feet high and (b) an
approximately 130-foot-long by 40-footwide by 10-foot-high steel powerhouse
containing nine turbine-generator units
having a capacity of 220 kilowatts each;
(4) a new short transmission line
connecting a new transportable 40-footlong by 8-foot-wide by 8-foot-high grid
interface unit to an existing 34.5-kV or
lower voltage grid distribution or subtransmission line; and (5) appurtenant
facilities. The development would have
an annual generation of 7,133 MWh.
Lock E15 Fort Plain Development
would consist of: (1) An existing 430foot-long, 8-foot-high bridge type dam;
(2) an existing 578-acre impoundment at
an elevation of 300.31 feet NAVD 88; (3)
two new identical modular steel
transportable barges, with each barge
resting on a foundation consisting of
four steel reinforced concrete pylons
and consisting of: (a) A steel intake
structure approximately 130 feet long by
40 feet wide by 15 feet high and (b) an
approximately 130-foot-long by 40-footwide by 10-foot-high steel powerhouse
containing nine turbine-generator units
having a capacity of 220 kilowatts each;
(4) a new short transmission line
connecting a new transportable 40-footlong by 8-foot-wide by 8-foot-high grid
interface unit to an existing 34.5-kV or
lower voltage grid distribution or subtransmission line; and (5) appurtenant
facilities. The development would have
an annual generation of 6,879 MWh.
Each development would be operated
during the navigation season (May
through November) only. The proposed
transportable barges would be deployed
at the beginning of each navigation
season and removed at the close of the
navigation season.
o. A copy of the application is
available for electronic review at the
Commission in the Public Reference
Room or may be viewed on the
Commission’s Web site at https://
www.ferc.gov using the ‘‘eLibrary’’ link.
Enter the docket number excluding the
last three digits in the docket number
field to access the document. For
assistance, contact FERC Online
Support. A copy is also available for
inspection and reproduction at the
address in item h above.
You may also register online at https://
www.ferc.gov/docs-filing/
esubscription.asp to be notified via
email of new filings and issuances
related to this or other pending projects.
For assistance, contact FERC Online
Support.
p. Procedural schedule: The
application will be processed according
to the following preliminary Hydro
Licensing Schedule. Revisions to the
schedule will be made as appropriate.
Milestone
Date
Issue Acceptance or Deficiency Letter ....................................................................................................................................
VerDate Sep<11>2014
17:14 Nov 14, 2014
Jkt 235001
PO 00000
Frm 00024
Fmt 4703
Sfmt 4703
E:\FR\FM\17NON1.SGM
17NON1
January 2015.
68429
Federal Register / Vol. 79, No. 221 / Monday, November 17, 2014 / Notices
Milestone
Date
Request Additional Information ...............................................................................................................................................
Issue Notice of Acceptance .....................................................................................................................................................
Issue Scoping Document 1 for Comments .............................................................................................................................
Hold Scoping Meeting .............................................................................................................................................................
Comments Due on Scoping Document 1 ................................................................................................................................
Issue Scoping Document 2 .....................................................................................................................................................
Issue Notice of Ready for Environmental Analysis .................................................................................................................
Commission Issues EA ............................................................................................................................................................
Dated: November 7, 2014.
Kimberly D. Bose,
Secretary.
[FR Doc. 2014–27054 Filed 11–14–14; 8:45 am]
BILLING CODE 6717–01–P
DEPARTMENT OF ENERGY
Federal Energy Regulatory
Commission
Combined Notice of Filings
Take notice that the Commission has
received the following Natural Gas
Pipeline Rate and Refund Report filings:
asabaliauskas on DSK5VPTVN1PROD with NOTICES
Filings Instituting Proceedings
Docket Numbers: RP15–148–000.
Applicants: Transcontinental Gas
Pipe Line Company.
Description: § 4(d) rate filing per
154.204: GT&C Section 39 Shipper
Consent Timeline to be effective 12/6/
2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5001.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP15–149–000.
Applicants: Iroquois Gas
Transmission System, L.P.
Description: § 4(d) rate filing per
154.204: 11/05/14 Negotiated Rates—
Trafigura AG (RTS) 7445–04 to be
effective 11/6/2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5053.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP15–150–000.
Applicants: Iroquois Gas
Transmission System, L.P.
Description: § 4(d) rate filing per
154.204: 11/05/14 Negotiated Rates—
Trafigura AG (HUB) 7445–89 to be
effective 11/6/2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5071.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP15–151–000.
Applicants: Enable Gas Transmission,
LLC.
Description: § 4(d) rate filing per
154.204: Negotiated Rate Filing—
November 2014—LER 1010222 Att A to
be effective 11/5/2014.
Filed Date: 11/5/14.
VerDate Sep<11>2014
17:14 Nov 14, 2014
Jkt 235001
Accession Number: 20141105–5163.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP15–152–000.
Applicants: Natural Gas Pipeline
Company of America.
Description: § 4(d) rate filing per
154.204: Removal of Expiring
Agreement to be effective 12/6/2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5232.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP15–153–000.
Applicants: Midcontinent Express
Pipeline LLC.
Description: § 4(d) rate filing per
154.204: Removing Expired Agreements
to be effective 12/6/2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5233.
Comments Due: 5 p.m. ET 11/17/14.
Any person desiring to intervene or
protest in any of the above proceedings
must file in accordance with Rules 211
and 214 of the Commission’s
Regulations (18 CFR 385.211 and
385.214) on or before 5:00 p.m. Eastern
time on the specified comment date.
Protests may be considered, but
intervention is necessary to become a
party to the proceeding.
Filings in Existing Proceedings
Docket Numbers: RP14–877–001.
Applicants: Northwest Pipeline LLC.
Description: Compliance filing per
154.203: Supplement to Order to Show
Cause Filing to be effective 11/1/2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5002.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP14–934–001.
Applicants: Questar Southern Trails
Pipeline Company.
Description: Compliance filing per
154.203: Order to Show Cause
Compliance Filing to be effective 6/16/
2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5193.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP14–935–002.
Applicants: Questar Overthrust
Pipeline Company.
Description: Compliance filing per
154.203: Show Cause Order Compliance
Filing to be effective 11/30/2014.
PO 00000
Frm 00025
Fmt 4703
Sfmt 4703
January 2015.
April 2015.
May 2015.
June 2015.
July 2015.
August 2015.
August 2015.
February 2016.
Filed Date: 11/5/14.
Accession Number: 20141105–5194.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP14–936–001.
Applicants: White River Hub, LLC.
Description: Compliance filing per
154.203: Order to Show Cause
Compliance Filing to be effective 6/16/
2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5192.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP14–946–001.
Applicants: Southern Natural Gas
Company, L.L.C.
Description: Compliance filing per
154.203: Show Cause Order—
Compliance Filing 2 to be effective 10/
16/2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5084.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP14–948–001.
Applicants: Southern LNG Company,
L.L.C.
Description: Compliance filing per
154.203: Show Cause Order—
Compliance Filing 2 to be effective 10/
16/2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5085.
Comments Due: 5 p.m. ET 11/17/14.
Docket Numbers: RP14–949–001.
Applicants: Elba Express Company,
L.L.C.
Description: Compliance filing per
154.203: Show Cause Order—
Compliance Filing 2 to be effective 10/
16/2014.
Filed Date: 11/5/14.
Accession Number: 20141105–5086.
Comments Due: 5 p.m. ET 11/17/14.
Any person desiring to protest in any
of the above proceedings must file in
accordance with Rule 211 of the
Commission’s Regulations (18 CFR
385.211) on or before 5:00 p.m. Eastern
time on the specified comment date.
The filings are accessible in the
Commission’s eLibrary system by
clicking on the links or querying the
docket number.
eFiling is encouraged. More detailed
information relating to filing
requirements, interventions, protests,
service, and qualifying facilities filings
E:\FR\FM\17NON1.SGM
17NON1
Agencies
[Federal Register Volume 79, Number 221 (Monday, November 17, 2014)]
[Notices]
[Pages 68427-68429]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2014-27054]
-----------------------------------------------------------------------
DEPARTMENT OF ENERGY
Federal Energy Regulatory Commission
[Project No. 12636-002]
Mohawk Hydro Corporation; Notice of Application Tendered for
Filing With the Commission and Soliciting Additional Study Requests
Take notice that the following hydroelectric application has been
filed with the Commission and is available for public inspection.
a. Type of Application: Original Major License
b. Project No.: 12636-002
c. Date filed: October 24, 2014
d. Applicant: Mohawk Hydro Corporation
e. Name of Project: Middle Mohawk Hydroelectric Project
f. Location: The project would be located on the Mohawk River, in
Schenectady and Montgomery Counties, New York.
g. Filed Pursuant to: Federal Power Act 16 U.S.C. 791(a)-825(r).
h. Applicant Contact: Wendy Jo Carey, Mohawk Hydro Corporation, 5
Washington Square, Albany, NY 12205; or at (518) 456-7712.
i. FERC Contact: Monir Chowdhury, (202) 502-6736 or
monir.chowdhury@ferc.gov
j. Cooperating agencies: Federal, state, local, and tribal agencies
with jurisdiction and/or special expertise with respect to
environmental issues that wish to cooperate in the preparation of the
environmental document should follow the instructions for filing such
requests described in item l below. Cooperating agencies should note
the Commission's policy that agencies that cooperate in the preparation
of the environmental document cannot also intervene. See, 94 FERC ]
61,076 (2001).
k. Pursuant to section 4.32(b)(7) of 18 CFR of the Commission's
regulations, if any resource agency, Indian Tribe, or person believes
that an additional scientific study should be conducted in order to
form an adequate factual basis for a complete analysis of the
application on its merit, the resource agency, Indian Tribe, or person
must file a request for a study with the Commission not later than 60
days from the date of filing of the application, and serve a copy of
the request on the applicant.
l. Deadline for filing additional study requests and requests for
cooperating agency status: December 23, 2014.
The Commission strongly encourages electronic filing. Please file
additional study requests and requests for cooperating agency status
using the Commission's eFiling system at https://www.ferc.gov/docs-filing/efiling.asp. For assistance, please contact FERC Online Support
at FERCOnlineSupport@ferc.gov, (866) 208-3676 (toll free), or (202)
502-8659 (TTY). In lieu of electronic filing, please send a paper copy
to: Secretary, Federal Energy Regulatory Commission, 888 First Street
NE., Washington, DC 20426. The first page of any filing should include
docket number P-12636-002.
m. The application is not ready for environmental analysis at this
time.
n. The proposed project would be located at eight existing lock and
dam facilities (Lock Numbers: E8 through E15) that are owned by the New
York State Canal Corporation. The proposed run-of-river project would
consist of the following eight developments:
Lock E8 Scotia Development would consist of: (1) An existing 530-
foot-long, 14-foot-high bridge type dam; (2) an existing 336-acre
impoundment at an elevation of 223.44 feet North Atlantic Vertical
Datum of 1988 (NAVD 88); (3) two new identical modular steel
transportable barges, with each barge resting on a foundation
consisting of four steel reinforced concrete pylons and consisting of:
(a) A steel intake structure approximately 130 feet long by 40 feet
wide by 15 feet high and (b) an approximately 130-foot-long by 40-foot-
wide by 10-foot-high steel powerhouse containing nine turbine-generator
units having a capacity of 220 kilowatts (kW) each; (4) a new short
transmission line connecting a new transportable 40-foot-long by 8-
foot-wide by 8-foot-high grid interface unit to an existing 34.5-
kilovolt (kV) or lower voltage grid distribution or sub-transmission
line; and (5) appurtenant facilities. The development would have an
annual generation of 15,473 megawatt-hours (MWh).
Lock E9 Rotterdam Junction Development would consist of: (1) An
existing 530-foot-long, 15-foot-high bridge type dam; (2) an existing
428-acre impoundment at an elevation of 238.78 feet NAVD 88; (3) two
new identical modular steel transportable barges, with
[[Page 68428]]
each barge resting on a foundation consisting of four steel reinforced
concrete pylons and consisting of: (a) A steel intake structure
approximately 130 feet long by 40 feet wide by 15 feet high and (b) an
approximately 130-foot-long by 40-foot-wide by 10-foot-high steel
powerhouse containing nine turbine-generator units having a capacity of
220 kW each; (4) a new short transmission line connecting a new
transportable 40-foot-long by 8-foot-wide by 8-foot-high grid interface
unit to an existing 34.5-kV or lower voltage grid distribution or sub-
transmission line; and (5) appurtenant facilities. The development
would have an annual generation of 16,440 MWh.
Lock E10 Cranesville Development would consist of: (1) An existing
500-foot-long, 15-foot-high bridge type dam; (2) an existing 414-acre
impoundment at an elevation of 253.37 feet NAVD 88; (3) two new
identical modular steel transportable barges, with each barge resting
on a foundation consisting of four steel reinforced concrete pylons and
consisting of: (a) A steel intake structure approximately 130 feet long
by 40 feet wide by 15 feet high and (b) an approximately 130-foot-long
by 40-foot-wide by 10-foot-high steel powerhouse containing nine
turbine-generator units having a capacity of 220 kilowatts each; (4) a
new short transmission line connecting a new transportable 40-foot-long
by 8-foot-wide by 8-foot-high grid interface unit to an existing 34.5-
kV or lower voltage grid distribution or sub-transmission line; and (5)
appurtenant facilities. The development would have an annual generation
of 16,296 MWh.
Lock E11 Amsterdam Development would consist of: (1) An existing
588-foot-long, 12-foot-high bridge type dam; (2) an existing 414-acre
impoundment at an elevation of 265.44 feet NAVD 88; (3) two new
identical modular steel transportable barges, with each barge resting
on a foundation consisting of four steel reinforced concrete pylons and
consisting of: (a) A steel intake structure approximately 130 feet long
by 40 feet wide by 15 feet high and (b) an approximately 130-foot-long
by 40-foot-wide by 10-foot-high steel powerhouse containing nine
turbine-generator units having a capacity of 220 kilowatts each; (4) a
new short transmission line connecting a new transportable 40-foot-long
by 8-foot-wide by 8-foot-high grid interface unit to an existing 34.5-
kV or lower voltage grid distribution or sub-transmission line; and (5)
appurtenant facilities. The development would have an annual generation
of 12,461 MWh.
Lock E12 Tribes Hill Development would consist of: (1) An existing
460-foot-long, 11-foot-high bridge type dam; (2) an existing 737-acre
impoundment at an elevation of 276.52 feet NAVD 88; (3) two new
identical modular steel transportable barges, with each barge resting
on a foundation consisting of four steel reinforced concrete pylons and
consisting of: (a) A steel intake structure approximately 130 feet long
by 40 feet wide by 15 feet high and (b) an approximately 130-foot-long
by 40-foot-wide by 10-foot-high steel powerhouse containing nine
turbine-generator units having a capacity of 220 kilowatts each; (4) a
new short transmission line connecting a new transportable 40-foot-long
by 8-foot-wide by 8-foot-high grid interface unit to an existing 34.5-
kV or lower voltage grid distribution or sub-transmission line; and (5)
appurtenant facilities. The development would have an annual generation
of 11,266 MWh.
Lock E13 Randall Development would consist of: (1) An existing 370-
foot-long, 8-foot-high bridge type dam; (2) an existing 464-acre
impoundment at an elevation of 284.52 feet NAVD 88; (3) two new
identical modular steel transportable barges, with each barge resting
on a foundation consisting of four steel reinforced concrete pylons and
consisting of: (a) A steel intake structure approximately 130 feet long
by 40 feet wide by 15 feet high and (b) an approximately 130-foot-long
by 40-foot-wide by 10-foot-high steel powerhouse containing nine
turbine-generator units having a capacity of 220 kilowatts each; (4) a
new short transmission line connecting a new transportable 40-foot-long
by 8-foot-wide by 8-foot-high grid interface unit to an existing 34.5-
kV or lower voltage grid distribution or sub-transmission line; and (5)
appurtenant facilities. The development would have an annual generation
of 7,734 MWh.
Lock E14 Canajoharie Development would consist of: (1) An existing
430-foot-long, 8-foot-high bridge type dam; (2) an existing 219-acre
impoundment at an elevation of 292.38 feet NAVD 88; (3) two new
identical modular steel transportable barges, with each barge resting
on a foundation consisting of four steel reinforced concrete pylons and
consisting of: (a) A steel intake structure approximately 130 feet long
by 40 feet wide by 15 feet high and (b) an approximately 130-foot-long
by 40-foot-wide by 10-foot-high steel powerhouse containing nine
turbine-generator units having a capacity of 220 kilowatts each; (4) a
new short transmission line connecting a new transportable 40-foot-long
by 8-foot-wide by 8-foot-high grid interface unit to an existing 34.5-
kV or lower voltage grid distribution or sub-transmission line; and (5)
appurtenant facilities. The development would have an annual generation
of 7,133 MWh.
Lock E15 Fort Plain Development would consist of: (1) An existing
430-foot-long, 8-foot-high bridge type dam; (2) an existing 578-acre
impoundment at an elevation of 300.31 feet NAVD 88; (3) two new
identical modular steel transportable barges, with each barge resting
on a foundation consisting of four steel reinforced concrete pylons and
consisting of: (a) A steel intake structure approximately 130 feet long
by 40 feet wide by 15 feet high and (b) an approximately 130-foot-long
by 40-foot-wide by 10-foot-high steel powerhouse containing nine
turbine-generator units having a capacity of 220 kilowatts each; (4) a
new short transmission line connecting a new transportable 40-foot-long
by 8-foot-wide by 8-foot-high grid interface unit to an existing 34.5-
kV or lower voltage grid distribution or sub-transmission line; and (5)
appurtenant facilities. The development would have an annual generation
of 6,879 MWh.
Each development would be operated during the navigation season
(May through November) only. The proposed transportable barges would be
deployed at the beginning of each navigation season and removed at the
close of the navigation season.
o. A copy of the application is available for electronic review at
the Commission in the Public Reference Room or may be viewed on the
Commission's Web site at https://www.ferc.gov using the ``eLibrary''
link. Enter the docket number excluding the last three digits in the
docket number field to access the document. For assistance, contact
FERC Online Support. A copy is also available for inspection and
reproduction at the address in item h above.
You may also register online at https://www.ferc.gov/docs-filing/esubscription.asp to be notified via email of new filings and issuances
related to this or other pending projects. For assistance, contact FERC
Online Support.
p. Procedural schedule: The application will be processed according
to the following preliminary Hydro Licensing Schedule. Revisions to the
schedule will be made as appropriate.
------------------------------------------------------------------------
Milestone Date
------------------------------------------------------------------------
Issue Acceptance or Deficiency January 2015.
Letter.
[[Page 68429]]
Request Additional Information...... January 2015.
Issue Notice of Acceptance.......... April 2015.
Issue Scoping Document 1 for May 2015.
Comments.
Hold Scoping Meeting................ June 2015.
Comments Due on Scoping Document 1.. July 2015.
Issue Scoping Document 2............ August 2015.
Issue Notice of Ready for August 2015.
Environmental Analysis.
Commission Issues EA................ February 2016.
------------------------------------------------------------------------
Dated: November 7, 2014.
Kimberly D. Bose,
Secretary.
[FR Doc. 2014-27054 Filed 11-14-14; 8:45 am]