Notice of Petition for Waiver of Samsung Electronics America, Inc. from the Department of Energy Residential Refrigerator and Refrigerator-Freezer Test Procedure, and Grant of Interim Waiver, 15937-15941 [2013-05771]
Download as PDF
Federal Register / Vol. 78, No. 49 / Wednesday, March 13, 2013 / Notices
graduation information to the
Department of Education (Department)
with a certification signed by the
institutions President/CEO/Chancellor
as well as for disseminating that
information to prospective U.S.
students. The Departments regulations,
at 34 CFR 668.14(b)(7), require Title IV
participating institutions to submit
reports to the Department containing
such information as the Secretary may
reasonably require to carry out the
purposes of the Title IV, HEA programs.
This is being done to improve consumer
information by providing more specific
consumer information to prospective
U.S. medical students at foreign
institutions.
Dated: March 7, 2013.
Kate Mullan,
Acting Director, Information Collection
Clearance Division, Privacy, Information and
Records Management Services, Office of
Management.
[FR Doc. 2013–05709 Filed 3–12–13; 8:45 am]
BILLING CODE 4000–01–P
DEPARTMENT OF ENERGY
Fusion Energy Sciences Advisory
Committee
Department of Energy, Office of
Science.
ACTION: Notice of open meeting.
AGENCY:
This notice announces a
meeting of the Fusion Energy Sciences
Advisory Committee. The Federal
Advisory Committee Act requires that
public notice of these meetings be
announced in the Federal Register.
DATES: Friday, March 15, 2013 9 a.m. to
5:45 p.m.
ADDRESSES: Bolger Center, 9600
Newbridge Drive, Potomac, Maryland
20854–4436.
FOR FURTHER INFORMATION CONTACT:
Edmund J. Synakowski, Designated
Federal Officer, Office of Fusion Energy
Sciences; U.S. Department of Energy;
1000 Independence Avenue SW.;
Washington, DC 20585–1290;
Telephone: 301–903–4941.
SUPPLEMENTARY INFORMATION: Purpose of
the Meeting: To complete the charge
given to the Committee in the letter
from the Director, Office of Science,
dated December 20, 2012, asking the
Fusion Energy Sciences Advisory
Committee to provide input and advice
on new or upgraded scientific user
facilities that could contribute to world
leading science during 2014–2024
necessary to position the DOE Office of
Science at the forefront of scientific
discovery.
mstockstill on DSK4VPTVN1PROD with NOTICES
SUMMARY:
VerDate Mar<15>2010
17:11 Mar 12, 2013
Jkt 229001
Tentative Agenda:
• DOE/SC perspective and FY 2014
Congressional Budget Request*
• FES perspective and FY 2014
Congressional Budget Request for FES*
• Report from the Subcommittee
dealing the charge on Scientific User
Facilities
• Status of the ITER Project
• Public Comments
*The budget discussion will be part of
the agenda only if the President’s
Budget Request for FY 2014 has been
sent to the Congress before the date of
this meeting.
Note: The FESAC meeting will be
broadcast live on the Internet. You may find
out how to access this broadcast by going to
the following site prior to the start of the
meeting. A video record of the meeting
including the presentations that are made
will be archived at this site after the meeting
ends: https://doe.granicus.com/
ViewPublisher.php?view_id=3
Public Participation: The meeting is
open to the public. If you would like to
file a written statement with the
Committee, you may do so either before
or after the meeting. If you would like
to make oral statements regarding any of
the items on the agenda, you should
contact Dr. Ed Synakowski at 301–903–
8584 (fax) or
Ed.synakowski@science.doe.gov (email).
Reasonable provision will be made to
include the scheduled oral statements
during the Public Comments time on the
agenda. The Chairperson of the
Committee will conduct the meeting to
facilitate the orderly conduct of
business. Public comment will follow
the 10-minute rule.
This notice is being published less
than 15 days prior to the meeting date
due to programmatic issues that had to
be resolved prior to the meeting date.
Minutes: The minutes of the meeting
will be available for public review and
copying within the Fusion Energy
Sciences Advisory Committee Web site
at: https://www.science.doe.gov/ofes/
fesac.shtml.
Issued at Washington, DC, on March 11,
2013.
LaTanya R. Butler,
Deputy Committee Management Officer.
[FR Doc. 2013–05903 Filed 3–11–13; 4:15 pm]
BILLING CODE 6450–01–P
PO 00000
Frm 00010
Fmt 4703
Sfmt 4703
15937
DEPARTMENT OF ENERGY
Office of Energy Efficiency and
Renewable Energy
[Case No. RF–027]
Notice of Petition for Waiver of
Samsung Electronics America, Inc.
from the Department of Energy
Residential Refrigerator and
Refrigerator-Freezer Test Procedure,
and Grant of Interim Waiver
Office of Energy Efficiency and
Renewable Energy, Department of
Energy.
ACTION: Notice of petition for waiver,
notice of grant of interim waiver, and
request for comments.
AGENCY:
This notice announces receipt
of a petition for waiver from Samsung
Electronics America, Inc. (Samsung)
regarding specified portions of the U.S.
Department of Energy (DOE) test
procedure for determining the energy
consumption of electric refrigerators
and refrigerator-freezers. In its petition,
Samsung provides an alternate test
procedure that is the same as the test
procedure DOE published in a final rule
setting out testing requirements for
manufacturers to follow starting in
2014. DOE solicits comments, data, and
information concerning Samsung’s
petition and the suggested alternate test
procedure. Today’s notice also grants
Samsung an interim waiver from the
electric refrigerator and refrigeratorfreezer test procedure, subject to use of
the alternative test procedure set forth
in this notice.
DATES: DOE will accept comments, data,
and information with respect to the
Samsung Petition until April 12, 2013.
ADDRESSES: You may submit comments,
identified by case number ‘‘RF–027,’’ by
any of the following methods:
• Federal eRulemaking Portal: https://
www.regulations.gov. Follow the
instructions for submitting comments.
• Email:
AS_Waiver_Requests@ee.doe.gov
Include the case number (Case No. RF–
027) in the subject line of the message.
• Mail: Ms. Brenda Edwards, U.S.
Department of Energy, Building
Technologies Program, Mailstop EE–2J/
1000 Independence Avenue SW.,
Washington, DC 20585–0121.
Telephone: (202) 586–2945. Please
submit one signed original paper copy.
• Hand Delivery/Courier: Ms. Brenda
Edwards, U.S. Department of Energy,
Building Technologies Program, 950
L’Enfant Plaza SW., Suite 600,
Washington, DC 20024. Please submit
one signed original paper copy.
SUMMARY:
E:\FR\FM\13MRN1.SGM
13MRN1
15938
Federal Register / Vol. 78, No. 49 / Wednesday, March 13, 2013 / Notices
Docket: For access to the docket to
review the background documents
relevant to this matter, you may visit the
U.S. Department of Energy, 950 L’Enfant
Plaza SW., Washington, DC, 20024;
(202) 586–2945, between 9:00 a.m. and
4:00 p.m., Monday through Friday,
except Federal holidays. Available
documents include the following items:
(1) This notice; (2) public comments
received; (3) the petition for waiver and
application for interim waiver; and (4)
prior DOE waivers and rulemakings
regarding similar refrigerator-freezer
products. Please call Ms. Brenda
Edwards at the above telephone number
for additional information.
FOR FURTHER INFORMATION CONTACT: Mr.
Bryan Berringer, U.S. Department of
Energy, Building Technologies Program,
Mail Stop EE–2J, Forrestal Building,
1000 Independence Avenue SW.,
Washington, DC 20585–0121.
Telephone: (202) 586–0371. Email:
Bryan.Berringer@ee.doe.gov.
Ms. Elizabeth Kohl, U.S. Department
of Energy, Office of the General Counsel,
Mail Stop GC–71, Forrestal Building,
1000 Independence Avenue SW.,
Washington, DC 20585–0103.
Telephone: (202) 586–7796. Email:
Elizabeth.Kohl@hq.doe.gov.
SUPPLEMENTARY INFORMATION:
mstockstill on DSK4VPTVN1PROD with NOTICES
I. Background and Authority
Title III, Part B of the Energy Policy
and Conservation Act of 1975 (EPCA),
Public Law 94–163 (42 U.S.C. 6291–
6309, as codified), established the
Energy Conservation Program for
Consumer Products Other Than
Automobiles, a program covering most
major household appliances, which
includes the electric refrigerators and
refrigerator-freezers that are the focus of
this notice.1 Part B includes definitions,
test procedures, labeling provisions,
energy conservation standards, and the
authority to require information and
reports from manufacturers. Further,
Part B authorizes the Secretary of
Energy to prescribe test procedures that
are reasonably designed to produce
results which measure the energy
efficiency, energy use, or estimated
annual operating costs of a covered
product, and that are not unduly
burdensome to conduct. (42 U.S.C.
6293(b)(3)) The test procedure for
electric refrigerators and refrigeratorfreezers is contained in 10 CFR part 430,
subpart B, appendix A1.
The regulations set forth in 10 CFR
430.27 contain provisions that enable a
person to seek a waiver from the test
1 For editorial reasons, upon codification in the
U.S. Code, Part B was re-designated Part A.
VerDate Mar<15>2010
17:11 Mar 12, 2013
Jkt 229001
procedure requirements for covered
products. The Assistant Secretary for
Energy Efficiency and Renewable
Energy (the Assistant Secretary) will
grant a waiver if it is determined that
the basic model for which the petition
for waiver was submitted contains one
or more design characteristics that
prevents testing of the basic model
according to the prescribed test
procedures, or if the prescribed test
procedures may evaluate the basic
model in a manner so unrepresentative
of its true energy consumption
characteristics as to provide materially
inaccurate comparative data. 10 CFR
430.27(l). Petitioners must include in
their petition any alternate test
procedures known to the petitioner to
evaluate the basic model in a manner
representative of its energy
consumption. The Assistant Secretary
may grant the waiver subject to
conditions, including adherence to
alternate test procedures. 10 CFR
430.27(l). Waivers remain in effect
pursuant to the provisions of 10 CFR
430.27(m).
The waiver process also allows the
Assistant Secretary to grant an interim
waiver from test procedure
requirements to manufacturers that have
petitioned DOE for a waiver of such
prescribed test procedures. 10 CFR
430.27(g). An interim waiver remains in
effect for 180 days or until DOE issues
its determination on the petition for
waiver, whichever occurs earlier. DOE
may extend an interim waiver for an
additional 180 days. 10 CFR 430.27(h).
II. Petition for Waiver of Test Procedure
and Application for Interim Waiver
On February 5, 2013, Samsung
submitted a petition for waiver from the
test procedure applicable to residential
electric refrigerators and refrigeratorfreezers set forth in 10 CFR part 430,
subpart B, appendix A1. Samsung is
designing new refrigerator-freezers that
incorporate multiple defrost cycles. In
its petition, Samsung seeks a waiver
from the existing DOE test procedure
applicable to refrigerators and
refrigerator-freezers under 10 CFR part
430 because the existing test procedure
does not account for multiple defrost
cycles. Therefore, Samsung has asked to
use an alternate test procedure that is
the same as the test procedure
provisions for products with long time
or variable defrost DOE published in a
final rule (77 FR 3559, 3564–3565,
January 25, 2012). These provisions
were placed in appendix A, which is
not required for use until September 15,
2014, and not in the current appendix
A1 test procedure. On January 27, July
19, and December 14, 2011, Samsung
PO 00000
Frm 00011
Fmt 4703
Sfmt 4703
had submitted similar petitions for
waiver and requests for interim waiver
for other basic models of refrigeratorfreezers that incorporate multiple
defrost cycles. DOE subsequently
granted a waiver for the products
specified in these petitions. 77 FR 1474
(Jan. 10, 2012) and 77 FR 75428 (Dec.
20, 2012).
Samsung also requests an interim
waiver from the existing DOE test
procedure. An interim waiver may be
granted if it is determined that the
applicant will experience economic
hardship if the application for interim
waiver is denied, if it appears likely that
the petition for waiver will be granted,
and/or the Assistant Secretary
determines that it would be desirable for
public policy reasons to grant
immediate relief pending a
determination of the petition for waiver.
10 CFR 430.27(g).
DOE has determined that Samsung’s
application for interim waiver does not
provide sufficient market, equipment
price, shipments and other
manufacturer impact information to
permit DOE to evaluate the economic
hardship Samsung might experience
absent a favorable determination on its
application for interim waiver. DOE has
determined, however, that it is likely
Samsung’s petition will be granted, and
that it is desirable for public policy
reasons to grant Samsung relief pending
a determination on the petition.
Previously, DOE granted a waiver to
Samsung for other basic models
incorporating multiple defrost
technology (77 FR 1474, Jan. 10, 2012
and 77 FR 75428, Dec. 20, 2012), and
DOE has determined that it is desirable
to have similar basic models tested in a
consistent manner.
Samsung’s petition included an
alternate test procedure to account for
the energy consumption of its
refrigerator-freezer models with
multiple defrost cycles. The alternate
test procedure specified by Samsung is
the same as the test procedure
published in the final rule referenced
above. The alternate test procedure
specified in this interim waiver (as well
as the previous waiver granted to
Samsung) is identical to the test
procedure provisions for products with
long time or variable defrost adopted in
the final test procedure rule that
manufacturers of these products are
required to use in 2014.
For the reasons stated above, DOE
grants Samsung’s application for interim
waiver from testing of its refrigeratorfreezer product line containing multiple
defrost cycles. Therefore, it is ordered
that:
E:\FR\FM\13MRN1.SGM
13MRN1
Federal Register / Vol. 78, No. 49 / Wednesday, March 13, 2013 / Notices
The application for interim waiver
filed by Samsung is hereby granted for
the specified Samsung refrigeratorfreezer basic model that incorporates
multiple defrost cycles, subject to the
specifications and conditions below.
Samsung shall be required to test or rate
the specified refrigerator-freezer product
according to the alternate test procedure
as set forth in section III, ‘‘Alternate Test
Procedure.’’
The interim waiver applies to the
following basic model:
RS27FD*****
DOE makes decisions on waivers and
interim waivers for only those models
specifically set out in the petition, not
future models that may be manufactured
by the petitioner. Samsung may submit
a subsequent petition for waiver and
request for grant of interim waiver, as
appropriate, for additional models of
refrigerator-freezers for which it seeks a
waiver from the DOE test procedure. In
addition, DOE notes that grant of an
interim waiver or waiver does not
release a petitioner from the
certification requirements set forth at 10
CFR part 429.
Further, this interim waiver is
conditioned upon the presumed validity
of statements, representations, and
documents provided by the petitioner.
DOE may revoke or modify this interim
waiver at any time upon a
determination that the factual basis
underlying the petition for waiver is
incorrect, or upon a determination that
the results from the alternate test
procedure are unrepresentative of the
basic models’ true energy consumption
characteristics.
III. Alternate Test Procedure
mstockstill on DSK4VPTVN1PROD with NOTICES
EPCA requires that manufacturers use
DOE test procedures to make
representations about the energy
consumption and energy consumption
costs of products covered by the statute.
VerDate Mar<15>2010
17:11 Mar 12, 2013
Jkt 229001
(42 U.S.C. 6293(c)) Consistent
representations are important for
manufacturers to use in making
representations about the energy
efficiency of their products and to
demonstrate compliance with
applicable DOE energy conservation
standards. Pursuant to its regulations
applicable to waivers and interim
waivers from applicable test procedures
at 10 CFR 430.27, DOE will consider
setting an alternate test procedure for
Samsung in a subsequent Decision and
Order.
During the period of the interim
waiver granted in this notice, Samsung
shall test the products listed above
according to the test procedures for
residential electric refrigerator-freezers
prescribed by DOE at 10 CFR part 430,
subpart B, appendix A1, except that, for
the Samsung products listed above only,
Samsung shall include the following:
1. In section 1, Definitions, the
following definition:
‘‘Defrost cycle type’’ means a distinct
sequence of control whose function is to
remove frost and/or ice from a
refrigerated surface. There may be
variations in the defrost control
sequence such as the number of defrost
heaters energized. Each such variation
establishes a separate distinct defrost
cycle type. However, defrost achieved
regularly during the compressor ‘‘off’’
cycles by warming of the evaporator
without active heat addition is not a
defrost cycle type.
2. In section 4, Test Period, the
following:
4.2.1 Long-time Automatic Defrost.
If the model being tested has a long-time
automatic defrost system, the two-part
test described in this section may be
used. The first part is a stable period of
compressor operation that includes no
portions of the defrost cycle, such as
precooling or recovery, that is otherwise
the same as the test for a unit having no
defrost provisions (section 4.1). The
PO 00000
Frm 00012
Fmt 4703
Sfmt 4703
15939
second part is designed to capture the
energy consumed during all of the
events occurring with the defrost
control sequence that are outside of
stable operation.
4.2.1.1 Cycling Compressor System.
For a system with a cycling compressor,
the second part of the test starts at the
termination of the last regular
compressor ‘‘on’’ cycle. The average
temperatures of the fresh food and
freezer compartments measured from
the termination of the previous
compressor ‘‘on’’ cycle to the
termination of the last regular
compressor ‘‘on’’ cycle must both be
within 0.5 °F (0.3 °C) of their average
temperatures measured for the first part
of the test. If any compressor cycles
occur prior to the defrost heater being
energized that cause the average
temperature in either compartment to
deviate from its average temperature for
the first part of the test by more than 0.5
°F (0.3 °C), these compressor cycles are
not considered regular compressor
cycles and must be included in the
second part of the test. As an example,
a ‘‘precooling’’ cycle, which is an
extended compressor cycle that lowers
the temperature(s) of one or both
compartments prior to energizing the
defrost heater, must be included in the
second part of the test. The test period
for the second part of the test ends at the
termination of the first regular
compressor ‘‘on’’ cycle after both
compartment temperatures have fully
recovered to their stable conditions. The
average temperatures of the
compartments measured from this
termination of the first regular
compressor ‘‘on’’ cycle until the
termination of the next regular
compressor ‘‘on’’ cycle must both be
within 0.5 °F (0.3 °C) of their average
temperatures measured for the first part
of the test. See Figure 1.
Billing Code 6450–01–P
E:\FR\FM\13MRN1.SGM
13MRN1
15940
Federal Register / Vol. 78, No. 49 / Wednesday, March 13, 2013 / Notices
CTLi = least or shortest compressor run time
between instances of defrost cycle type
i in hours rounded to the nearest tenth
of an hour (CTL for the defrost cycle type
with the longest compressor run time
between defrosts must be greater than or
equal to 6 but less than or equal to 12
hours);
CTMi = maximum compressor run time
between instances of defrost cycle type
i in hours rounded to the nearest tenth
of an hour (greater than CTLi but not
more than 96 hours);
For cases in which there are more than one
fixed CT value (for long-time defrost
models) or more than one CTM and/or
CTL value (for variable defrost models)
for a given defrost cycle type, an average
fixed CT value or average CTM and CTL
values shall be selected for this cycle
type so that 12 divided by this value or
values is the frequency of occurrence of
the defrost cycle type in a 24 hour
period, assuming 50% compressor run
time.
F = default defrost energy consumption
factor, equal to 0.20.
For variable defrost models with no values
for CTLi and CTMi in the algorithm, the
default values of 6 and 96 shall be used,
respectively.
D is the total number of distinct defrost cycle
types.
1440 is defined in 5.2.1.1 and EP1, T1, and
12 are defined in 5.2.1.2; i is a variable
that can equal 1, 2, or more that
identifies the distinct defrost cycle types
applicable for the refrigerator or
refrigerator-freezer;
EP2i = energy expended in kilowatt-hours
during the second part of the test for
defrost cycle type i;
T2i = length of time in minutes of the second
part of the test for defrost cycle type i;
CTi is the compressor run time between
instances of defrost cycle type i, for longtime automatic defrost control equal to a
fixed time in hours rounded to the
nearest tenth of an hour, and for variable
defrost control equal to
(CTLi × CTMi)/(F × (CTMi ¥ CTLi) + CTLi);
VerDate Mar<15>2010
17:11 Mar 12, 2013
Jkt 229001
PO 00000
Frm 00013
Fmt 4703
Sfmt 4703
IV. Summary and Request for
Comments
Through today’s notice, DOE
announces receipt of Samsung’s petition
E:\FR\FM\13MRN1.SGM
13MRN1
EN13MR13.001
5.2.1.5 Long-time or Variable Defrost
Control for Systems with Multiple
Defrost cycle Types. The energy
consumption in kilowatt-hours per day
shall be calculated equivalent to:
EN13MR13.000
have different defrost frequencies. The
two-part method in 4.2.1 shall be used.
The second part of the method will be
conducted separately for each distinct
defrost cycle type.
3. In section 5, Test Measurements,
the following:
Where:
mstockstill on DSK4VPTVN1PROD with NOTICES
4.2.4 Systems with Multiple Defrost
Frequencies. This section applies to
models with long-time automatic or
variable defrost control with multiple
defrost cycle types, such as models with
single compressors and multiple
evaporators in which the evaporators
Federal Register / Vol. 78, No. 49 / Wednesday, March 13, 2013 / Notices
for waiver from certain parts of the test
procedure that apply to refrigeratorfreezers and grants an interim waiver to
Samsung. DOE is publishing Samsung’s
petition for waiver in its entirety
pursuant to 10 CFR 430.27(b)(1)(iv). The
petition contains no confidential
information. The petition includes a
suggested alternate test procedure to
measure the energy consumption of
refrigerator-freezer basic models that
incorporate multiple defrost cycles.
DOE solicits comments from
interested parties on all aspects of the
petition. Pursuant to 10 CFR
430.27(b)(1)(iv), any person submitting
written comments to DOE must also
send a copy of such comments to the
petitioner. The contact information for
the petitioner is: Michael Moss, Director
of Corporate Environmental Affairs,
Samsung Electronics America, Inc., 19
Chapin Road, Building D, Pine Brook,
NJ 07058. All submissions received
must include the agency name and case
number for this proceeding. Submit
electronic comments in WordPerfect,
Microsoft Word, Portable Document
Format (PDF), or text (American
Standard Code for Information
Interchange (ASCII)) file format and
avoid the use of special characters or
any form of encryption. Wherever
possible, include the electronic
signature of the author. DOE does not
accept telefacsimiles (faxes).
Issued in Washington, DC, on March 7,
2013.
Kathleen B. Hogan,
Deputy Assistant Secretary for Energy
Efficiency, Energy Efficiency and Renewable
Energy.
mstockstill on DSK4VPTVN1PROD with NOTICES
February 5, 2013
Dr. David Danielson
Energy Efficiency and Renewable
Energy
Department of Energy
1000 Independence Avenue SW.
Washington, DC 20585
Dear Assistant Secretary Danielson:
Samsung Electronics America, Inc.
(‘‘Samsung’’) respectfully submits this
Application for Interim Waiver and
Petition for Waiver to the Department of
Energy (‘‘DOE’’ or ‘‘the Department’’) for
Samsung’s compressor refrigeratorfreezers with multiple defrost cycles.
Reasoning
10 CFR Part 430.27(a)(1) allows a
person to submit a petition to waive for
a particular basic model any
requirements of § 430.23 upon the
grounds that the basic model contains
one or more design characteristics
which either prevent testing of the basic
model according to the prescribed test
procedures, or the prescribed test
VerDate Mar<15>2010
17:11 Mar 12, 2013
Jkt 229001
procedures may evaluate the basic
model in a manner so unrepresentative
of its true energy consumption
characteristics as to provide materially
inaccurate comparative data.
Current test procedures as prescribed
in Appendix A1 to Subpart B of Part 430
(‘‘Appendix A1’’) do not adequately
provide a way for Samsung to accurately
represent the energy consumption of its
refrigerator-freezers with multiple
defrost cycles. DOE concurred with
Samsung’s understanding in the interim
waiver granted to Samsung in 76 FR
16760 2 and subsequently granted the
waiver on January 10, 2012 (77 FR
1474). Additionally, DOE
communicated that all manufacturers
planning on marketing refrigeratorfreezers with multiple defrost cycles
must seek a waiver from the
Department.3
For the reasons that DOE described in
its granting of waiver (77 FR 1474) for
Samsung refrigerator freezers with
multiple defrost cycles, Samsung
believes that the granting of Interim
Waiver and Waiver for the models listed
below are warranted.
Request
Samsung requests that the alternate
test procedure for refrigerators with
multiple defrost cycles, as prescribed in
the waiver (77 FR 1474) and in the
interim waiver (77 FR 13109) granted to
Samsung, be granted for the following
basic Samsung refrigerator-freezer with
multiple defrost cycles models:
RS27FD*****
Please feel free to contact me if you
have any questions regarding this
Petition for Waiver and Application for
Interim Waiver. I will be happy to
discuss should any questions arise.
Sincerely,
Michael Moss
Director of Corporate Environmental
Affairs
[FR Doc. 2013–05771 Filed 3–12–13; 8:45 am]
BILLING CODE 6450–01–P
2 DOE understands, however, that absent an
interim waiver, Samsung’s products would not be
accurately tested and rated for energy consumption
because the current energy test procedure does not
include test procedures for products with multiple
defrost cycle types.
3 Until these amendments are required in
conjunction with the 2014 standards, manufacturers
introducing products equipped with multiple
defrost cycle types should, consistent with 10 CFR
430.27, petition for a waiver since the modified
version of Appendix A1 set out in today’s notice
will not include a specified method for capturing
this energy usage.
PO 00000
Frm 00014
Fmt 4703
Sfmt 4703
15941
DEPARTMENT OF ENERGY
Office of Energy Efficiency and
Renewable Energy
[Case No. RF–026]
Petition for Waiver of Samsung
Electronics America, Inc. From the
Department of Energy Residential
Refrigerator and Refrigerator-Freezer
Test Procedure and Grant of Interim
Waiver
Office of Energy Efficiency and
Renewable Energy, Department of
Energy.
ACTION: Notice of petition for waiver,
notice of granting application for
interim waiver, and request for public
comments.
AGENCY:
This notice announces receipt
of a petition for waiver from Samsung
Electronics America, Inc. (Samsung)
seeking an exemption from specified
portions of the U.S. Department of
Energy (DOE) test procedure for
determining the energy consumption of
electric refrigerators and refrigeratorfreezers. Samsung asks that it be
permitted to use an alternate test
procedure to address the difficulties in
testing dual compressor systems
according to the currently applicable
DOE test procedure. DOE solicits
comments, data, and information
concerning Samsung’s petition and the
suggested alternate test procedure.
Today’s notice also grants Samsung
with an interim waiver from the electric
refrigerator-freezer test procedure,
subject to use of the alternative test
procedure set forth in this notice. The
waiver request pertains to the basic
models set forth in Samsung’s petition
that incorporate dual compressors.
DATES: DOE will accept comments, data,
and information with respect to the
Samsung Petition until April 12, 2013.
ADDRESSES: You may submit comments,
identified by case number ‘‘RF–026,’’ by
any of the following methods:
• Federal eRulemaking Portal: https://
www.regulations.gov. Follow the
instructions for submitting comments.
• Email:
AS_Waiver_Requests@ee.doe.gov
Include the case number [Case No. RF–
026] in the subject line of the message.
• Mail: Ms. Brenda Edwards, U.S.
Department of Energy, Building
Technologies Program, Mailstop EE–2J/
1000 Independence Avenue SW.,
Washington, DC 20585–0121.
Telephone: (202) 586–2945. Please
submit one signed original paper copy.
• Hand Delivery/Courier: Ms. Brenda
Edwards, U.S. Department of Energy,
SUMMARY:
E:\FR\FM\13MRN1.SGM
13MRN1
Agencies
[Federal Register Volume 78, Number 49 (Wednesday, March 13, 2013)]
[Notices]
[Pages 15937-15941]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2013-05771]
-----------------------------------------------------------------------
DEPARTMENT OF ENERGY
Office of Energy Efficiency and Renewable Energy
[Case No. RF-027]
Notice of Petition for Waiver of Samsung Electronics America,
Inc. from the Department of Energy Residential Refrigerator and
Refrigerator-Freezer Test Procedure, and Grant of Interim Waiver
AGENCY: Office of Energy Efficiency and Renewable Energy, Department of
Energy.
ACTION: Notice of petition for waiver, notice of grant of interim
waiver, and request for comments.
-----------------------------------------------------------------------
SUMMARY: This notice announces receipt of a petition for waiver from
Samsung Electronics America, Inc. (Samsung) regarding specified
portions of the U.S. Department of Energy (DOE) test procedure for
determining the energy consumption of electric refrigerators and
refrigerator-freezers. In its petition, Samsung provides an alternate
test procedure that is the same as the test procedure DOE published in
a final rule setting out testing requirements for manufacturers to
follow starting in 2014. DOE solicits comments, data, and information
concerning Samsung's petition and the suggested alternate test
procedure. Today's notice also grants Samsung an interim waiver from
the electric refrigerator and refrigerator-freezer test procedure,
subject to use of the alternative test procedure set forth in this
notice.
DATES: DOE will accept comments, data, and information with respect to
the Samsung Petition until April 12, 2013.
ADDRESSES: You may submit comments, identified by case number ``RF-
027,'' by any of the following methods:
Federal eRulemaking Portal: https://www.regulations.gov.
Follow the instructions for submitting comments.
Email: AS_Waiver_Requests@ee.doe.gov Include the case
number (Case No. RF-027) in the subject line of the message.
Mail: Ms. Brenda Edwards, U.S. Department of Energy,
Building Technologies Program, Mailstop EE-2J/1000 Independence Avenue
SW., Washington, DC 20585-0121. Telephone: (202) 586-2945. Please
submit one signed original paper copy.
Hand Delivery/Courier: Ms. Brenda Edwards, U.S. Department
of Energy, Building Technologies Program, 950 L'Enfant Plaza SW., Suite
600, Washington, DC 20024. Please submit one signed original paper
copy.
[[Page 15938]]
Docket: For access to the docket to review the background documents
relevant to this matter, you may visit the U.S. Department of Energy,
950 L'Enfant Plaza SW., Washington, DC, 20024; (202) 586-2945, between
9:00 a.m. and 4:00 p.m., Monday through Friday, except Federal
holidays. Available documents include the following items: (1) This
notice; (2) public comments received; (3) the petition for waiver and
application for interim waiver; and (4) prior DOE waivers and
rulemakings regarding similar refrigerator-freezer products. Please
call Ms. Brenda Edwards at the above telephone number for additional
information.
FOR FURTHER INFORMATION CONTACT: Mr. Bryan Berringer, U.S. Department
of Energy, Building Technologies Program, Mail Stop EE-2J, Forrestal
Building, 1000 Independence Avenue SW., Washington, DC 20585-0121.
Telephone: (202) 586-0371. Email: Bryan.Berringer@ee.doe.gov.
Ms. Elizabeth Kohl, U.S. Department of Energy, Office of the
General Counsel, Mail Stop GC-71, Forrestal Building, 1000 Independence
Avenue SW., Washington, DC 20585-0103. Telephone: (202) 586-7796.
Email: Elizabeth.Kohl@hq.doe.gov.
SUPPLEMENTARY INFORMATION:
I. Background and Authority
Title III, Part B of the Energy Policy and Conservation Act of 1975
(EPCA), Public Law 94-163 (42 U.S.C. 6291-6309, as codified),
established the Energy Conservation Program for Consumer Products Other
Than Automobiles, a program covering most major household appliances,
which includes the electric refrigerators and refrigerator-freezers
that are the focus of this notice.\1\ Part B includes definitions, test
procedures, labeling provisions, energy conservation standards, and the
authority to require information and reports from manufacturers.
Further, Part B authorizes the Secretary of Energy to prescribe test
procedures that are reasonably designed to produce results which
measure the energy efficiency, energy use, or estimated annual
operating costs of a covered product, and that are not unduly
burdensome to conduct. (42 U.S.C. 6293(b)(3)) The test procedure for
electric refrigerators and refrigerator-freezers is contained in 10 CFR
part 430, subpart B, appendix A1.
---------------------------------------------------------------------------
\1\ For editorial reasons, upon codification in the U.S. Code,
Part B was re-designated Part A.
---------------------------------------------------------------------------
The regulations set forth in 10 CFR 430.27 contain provisions that
enable a person to seek a waiver from the test procedure requirements
for covered products. The Assistant Secretary for Energy Efficiency and
Renewable Energy (the Assistant Secretary) will grant a waiver if it is
determined that the basic model for which the petition for waiver was
submitted contains one or more design characteristics that prevents
testing of the basic model according to the prescribed test procedures,
or if the prescribed test procedures may evaluate the basic model in a
manner so unrepresentative of its true energy consumption
characteristics as to provide materially inaccurate comparative data.
10 CFR 430.27(l). Petitioners must include in their petition any
alternate test procedures known to the petitioner to evaluate the basic
model in a manner representative of its energy consumption. The
Assistant Secretary may grant the waiver subject to conditions,
including adherence to alternate test procedures. 10 CFR 430.27(l).
Waivers remain in effect pursuant to the provisions of 10 CFR
430.27(m).
The waiver process also allows the Assistant Secretary to grant an
interim waiver from test procedure requirements to manufacturers that
have petitioned DOE for a waiver of such prescribed test procedures. 10
CFR 430.27(g). An interim waiver remains in effect for 180 days or
until DOE issues its determination on the petition for waiver,
whichever occurs earlier. DOE may extend an interim waiver for an
additional 180 days. 10 CFR 430.27(h).
II. Petition for Waiver of Test Procedure and Application for Interim
Waiver
On February 5, 2013, Samsung submitted a petition for waiver from
the test procedure applicable to residential electric refrigerators and
refrigerator-freezers set forth in 10 CFR part 430, subpart B, appendix
A1. Samsung is designing new refrigerator-freezers that incorporate
multiple defrost cycles. In its petition, Samsung seeks a waiver from
the existing DOE test procedure applicable to refrigerators and
refrigerator-freezers under 10 CFR part 430 because the existing test
procedure does not account for multiple defrost cycles. Therefore,
Samsung has asked to use an alternate test procedure that is the same
as the test procedure provisions for products with long time or
variable defrost DOE published in a final rule (77 FR 3559, 3564-3565,
January 25, 2012). These provisions were placed in appendix A, which is
not required for use until September 15, 2014, and not in the current
appendix A1 test procedure. On January 27, July 19, and December 14,
2011, Samsung had submitted similar petitions for waiver and requests
for interim waiver for other basic models of refrigerator-freezers that
incorporate multiple defrost cycles. DOE subsequently granted a waiver
for the products specified in these petitions. 77 FR 1474 (Jan. 10,
2012) and 77 FR 75428 (Dec. 20, 2012).
Samsung also requests an interim waiver from the existing DOE test
procedure. An interim waiver may be granted if it is determined that
the applicant will experience economic hardship if the application for
interim waiver is denied, if it appears likely that the petition for
waiver will be granted, and/or the Assistant Secretary determines that
it would be desirable for public policy reasons to grant immediate
relief pending a determination of the petition for waiver. 10 CFR
430.27(g).
DOE has determined that Samsung's application for interim waiver
does not provide sufficient market, equipment price, shipments and
other manufacturer impact information to permit DOE to evaluate the
economic hardship Samsung might experience absent a favorable
determination on its application for interim waiver. DOE has
determined, however, that it is likely Samsung's petition will be
granted, and that it is desirable for public policy reasons to grant
Samsung relief pending a determination on the petition. Previously, DOE
granted a waiver to Samsung for other basic models incorporating
multiple defrost technology (77 FR 1474, Jan. 10, 2012 and 77 FR 75428,
Dec. 20, 2012), and DOE has determined that it is desirable to have
similar basic models tested in a consistent manner.
Samsung's petition included an alternate test procedure to account
for the energy consumption of its refrigerator-freezer models with
multiple defrost cycles. The alternate test procedure specified by
Samsung is the same as the test procedure published in the final rule
referenced above. The alternate test procedure specified in this
interim waiver (as well as the previous waiver granted to Samsung) is
identical to the test procedure provisions for products with long time
or variable defrost adopted in the final test procedure rule that
manufacturers of these products are required to use in 2014.
For the reasons stated above, DOE grants Samsung's application for
interim waiver from testing of its refrigerator-freezer product line
containing multiple defrost cycles. Therefore, it is ordered that:
[[Page 15939]]
The application for interim waiver filed by Samsung is hereby
granted for the specified Samsung refrigerator-freezer basic model that
incorporates multiple defrost cycles, subject to the specifications and
conditions below. Samsung shall be required to test or rate the
specified refrigerator-freezer product according to the alternate test
procedure as set forth in section III, ``Alternate Test Procedure.''
The interim waiver applies to the following basic model:
RS27FD*****
DOE makes decisions on waivers and interim waivers for only those
models specifically set out in the petition, not future models that may
be manufactured by the petitioner. Samsung may submit a subsequent
petition for waiver and request for grant of interim waiver, as
appropriate, for additional models of refrigerator-freezers for which
it seeks a waiver from the DOE test procedure. In addition, DOE notes
that grant of an interim waiver or waiver does not release a petitioner
from the certification requirements set forth at 10 CFR part 429.
Further, this interim waiver is conditioned upon the presumed
validity of statements, representations, and documents provided by the
petitioner. DOE may revoke or modify this interim waiver at any time
upon a determination that the factual basis underlying the petition for
waiver is incorrect, or upon a determination that the results from the
alternate test procedure are unrepresentative of the basic models' true
energy consumption characteristics.
III. Alternate Test Procedure
EPCA requires that manufacturers use DOE test procedures to make
representations about the energy consumption and energy consumption
costs of products covered by the statute. (42 U.S.C. 6293(c))
Consistent representations are important for manufacturers to use in
making representations about the energy efficiency of their products
and to demonstrate compliance with applicable DOE energy conservation
standards. Pursuant to its regulations applicable to waivers and
interim waivers from applicable test procedures at 10 CFR 430.27, DOE
will consider setting an alternate test procedure for Samsung in a
subsequent Decision and Order.
During the period of the interim waiver granted in this notice,
Samsung shall test the products listed above according to the test
procedures for residential electric refrigerator-freezers prescribed by
DOE at 10 CFR part 430, subpart B, appendix A1, except that, for the
Samsung products listed above only, Samsung shall include the
following:
1. In section 1, Definitions, the following definition:
``Defrost cycle type'' means a distinct sequence of control whose
function is to remove frost and/or ice from a refrigerated surface.
There may be variations in the defrost control sequence such as the
number of defrost heaters energized. Each such variation establishes a
separate distinct defrost cycle type. However, defrost achieved
regularly during the compressor ``off'' cycles by warming of the
evaporator without active heat addition is not a defrost cycle type.
2. In section 4, Test Period, the following:
4.2.1 Long-time Automatic Defrost. If the model being tested has a
long-time automatic defrost system, the two-part test described in this
section may be used. The first part is a stable period of compressor
operation that includes no portions of the defrost cycle, such as
precooling or recovery, that is otherwise the same as the test for a
unit having no defrost provisions (section 4.1). The second part is
designed to capture the energy consumed during all of the events
occurring with the defrost control sequence that are outside of stable
operation.
4.2.1.1 Cycling Compressor System. For a system with a cycling
compressor, the second part of the test starts at the termination of
the last regular compressor ``on'' cycle. The average temperatures of
the fresh food and freezer compartments measured from the termination
of the previous compressor ``on'' cycle to the termination of the last
regular compressor ``on'' cycle must both be within 0.5 [deg]F (0.3
[deg]C) of their average temperatures measured for the first part of
the test. If any compressor cycles occur prior to the defrost heater
being energized that cause the average temperature in either
compartment to deviate from its average temperature for the first part
of the test by more than 0.5 [deg]F (0.3 [deg]C), these compressor
cycles are not considered regular compressor cycles and must be
included in the second part of the test. As an example, a
``precooling'' cycle, which is an extended compressor cycle that lowers
the temperature(s) of one or both compartments prior to energizing the
defrost heater, must be included in the second part of the test. The
test period for the second part of the test ends at the termination of
the first regular compressor ``on'' cycle after both compartment
temperatures have fully recovered to their stable conditions. The
average temperatures of the compartments measured from this termination
of the first regular compressor ``on'' cycle until the termination of
the next regular compressor ``on'' cycle must both be within 0.5 [deg]F
(0.3 [deg]C) of their average temperatures measured for the first part
of the test. See Figure 1.
Billing Code 6450-01-P
[[Page 15940]]
[GRAPHIC] [TIFF OMITTED] TN13MR13.000
4.2.4 Systems with Multiple Defrost Frequencies. This section
applies to models with long-time automatic or variable defrost control
with multiple defrost cycle types, such as models with single
compressors and multiple evaporators in which the evaporators have
different defrost frequencies. The two-part method in 4.2.1 shall be
used. The second part of the method will be conducted separately for
each distinct defrost cycle type.
3. In section 5, Test Measurements, the following:
5.2.1.5 Long-time or Variable Defrost Control for Systems with
Multiple Defrost cycle Types. The energy consumption in kilowatt-hours
per day shall be calculated equivalent to:
[GRAPHIC] [TIFF OMITTED] TN13MR13.001
Where:
1440 is defined in 5.2.1.1 and EP1, T1, and 12 are defined in
5.2.1.2; i is a variable that can equal 1, 2, or more that
identifies the distinct defrost cycle types applicable for the
refrigerator or refrigerator-freezer;
EP2i = energy expended in kilowatt-hours during the
second part of the test for defrost cycle type i;
T2i = length of time in minutes of the second part of the
test for defrost cycle type i;
CTi is the compressor run time between instances of
defrost cycle type i, for long-time automatic defrost control equal
to a fixed time in hours rounded to the nearest tenth of an hour,
and for variable defrost control equal to
(CTLi x CTMi)/(F x (CTMi -
CTLi) + CTLi);
CTLi = least or shortest compressor run time between
instances of defrost cycle type i in hours rounded to the nearest
tenth of an hour (CTL for the defrost cycle type with the
longest compressor run time between defrosts must be greater than or
equal to 6 but less than or equal to 12 hours);
CTMi = maximum compressor run time between instances of
defrost cycle type i in hours rounded to the nearest tenth of an
hour (greater than CTLi but not more than 96 hours);
For cases in which there are more than one fixed CT value (for long-
time defrost models) or more than one CTM and/or
CTL value (for variable defrost models) for a given
defrost cycle type, an average fixed CT value or average
CTM and CTL values shall be selected for this
cycle type so that 12 divided by this value or values is the
frequency of occurrence of the defrost cycle type in a 24 hour
period, assuming 50% compressor run time.
F = default defrost energy consumption factor, equal to 0.20.
For variable defrost models with no values for CTLi and
CTMi in the algorithm, the default values of 6 and 96
shall be used, respectively.
D is the total number of distinct defrost cycle types.
IV. Summary and Request for Comments
Through today's notice, DOE announces receipt of Samsung's petition
[[Page 15941]]
for waiver from certain parts of the test procedure that apply to
refrigerator-freezers and grants an interim waiver to Samsung. DOE is
publishing Samsung's petition for waiver in its entirety pursuant to 10
CFR 430.27(b)(1)(iv). The petition contains no confidential
information. The petition includes a suggested alternate test procedure
to measure the energy consumption of refrigerator-freezer basic models
that incorporate multiple defrost cycles.
DOE solicits comments from interested parties on all aspects of the
petition. Pursuant to 10 CFR 430.27(b)(1)(iv), any person submitting
written comments to DOE must also send a copy of such comments to the
petitioner. The contact information for the petitioner is: Michael
Moss, Director of Corporate Environmental Affairs, Samsung Electronics
America, Inc., 19 Chapin Road, Building D, Pine Brook, NJ 07058. All
submissions received must include the agency name and case number for
this proceeding. Submit electronic comments in WordPerfect, Microsoft
Word, Portable Document Format (PDF), or text (American Standard Code
for Information Interchange (ASCII)) file format and avoid the use of
special characters or any form of encryption. Wherever possible,
include the electronic signature of the author. DOE does not accept
telefacsimiles (faxes).
Issued in Washington, DC, on March 7, 2013.
Kathleen B. Hogan,
Deputy Assistant Secretary for Energy Efficiency, Energy Efficiency and
Renewable Energy.
February 5, 2013
Dr. David Danielson
Energy Efficiency and Renewable Energy
Department of Energy
1000 Independence Avenue SW.
Washington, DC 20585
Dear Assistant Secretary Danielson:
Samsung Electronics America, Inc. (``Samsung'') respectfully
submits this Application for Interim Waiver and Petition for Waiver to
the Department of Energy (``DOE'' or ``the Department'') for Samsung's
compressor refrigerator-freezers with multiple defrost cycles.
Reasoning
10 CFR Part 430.27(a)(1) allows a person to submit a petition to
waive for a particular basic model any requirements of Sec. 430.23
upon the grounds that the basic model contains one or more design
characteristics which either prevent testing of the basic model
according to the prescribed test procedures, or the prescribed test
procedures may evaluate the basic model in a manner so unrepresentative
of its true energy consumption characteristics as to provide materially
inaccurate comparative data.
Current test procedures as prescribed in Appendix A1 to Subpart B
of Part 430 (``Appendix A1'') do not adequately provide a way for
Samsung to accurately represent the energy consumption of its
refrigerator-freezers with multiple defrost cycles. DOE concurred with
Samsung's understanding in the interim waiver granted to Samsung in 76
FR 16760 \2\ and subsequently granted the waiver on January 10, 2012
(77 FR 1474). Additionally, DOE communicated that all manufacturers
planning on marketing refrigerator-freezers with multiple defrost
cycles must seek a waiver from the Department.\3\
---------------------------------------------------------------------------
\2\ DOE understands, however, that absent an interim waiver,
Samsung's products would not be accurately tested and rated for
energy consumption because the current energy test procedure does
not include test procedures for products with multiple defrost cycle
types.
\3\ Until these amendments are required in conjunction with the
2014 standards, manufacturers introducing products equipped with
multiple defrost cycle types should, consistent with 10 CFR 430.27,
petition for a waiver since the modified version of Appendix A1 set
out in today's notice will not include a specified method for
capturing this energy usage.
---------------------------------------------------------------------------
For the reasons that DOE described in its granting of waiver (77 FR
1474) for Samsung refrigerator freezers with multiple defrost cycles,
Samsung believes that the granting of Interim Waiver and Waiver for the
models listed below are warranted.
Request
Samsung requests that the alternate test procedure for
refrigerators with multiple defrost cycles, as prescribed in the waiver
(77 FR 1474) and in the interim waiver (77 FR 13109) granted to
Samsung, be granted for the following basic Samsung refrigerator-
freezer with multiple defrost cycles models:
RS27FD*****
Please feel free to contact me if you have any questions regarding
this Petition for Waiver and Application for Interim Waiver. I will be
happy to discuss should any questions arise.
Sincerely,
Michael Moss
Director of Corporate Environmental Affairs