Dominion Transmission, Inc; Notice of Request Under Blanket Authorization, 80926 [2011-32990]
Download as PDF
80926
Federal Register / Vol. 76, No. 248 / Tuesday, December 27, 2011 / Notices
DEPARTMENT OF ENERGY
Federal Energy Regulatory
Commission
[Project No. 14328–000]
sroberts on DSK5SPTVN1PROD with NOTICES
Cortez Pumped Storage Project; Notice
of Preliminary Permit Application
Accepted for Filing and Soliciting
Comments, Motions To Intervene, and
Competing Applications
On December 1, 2011, INCA
Engineers, Inc., Washington, filed an
application for a preliminary permit,
pursuant to section 4(f) of the Federal
Power Act (FPA), proposing to study the
feasibility of the Cortez Pumped Storage
Project to be located on Plateau Creek,
near the town of Dolores, Montezuma
County, Colorado. The project affects
Federal lands administered by the
Forest Service (San Juan National
Forest). The sole purpose of a
preliminary permit, if issued, is to grant
the permit holder priority to file a
license application during the permit
term. A preliminary permit does not
authorize the permit holder to perform
any land-disturbing activities or
otherwise enter upon lands or waters
owned by others without the owners’
express permission.
The proposed project would consist of
the following new facilities: (1) An
upper reservoir, formed by a 130-foothigh by 6,500-foot-long, rollercompacted concrete (RCC) dam, with a
total storage capacity of 8,000 acre-feet
and a water surface area of 275 acres at
full pool elevation; (2) a lower reservoir,
formed by a 270-foot-high by 800-footlong dam, having a total storage capacity
of 9,500 acre-feet and a water surface
area of 200 acres at full pool elevation;
(3) two 15-foot-diameter steel consisting
of a surface penstock, a vertical shaft
and an inclined tunnel; (4) two 27-footdiameter tailrace tunnels that would be
850-feet-long; (5) an underground
powerhouse containing two reversible
pump-turbines totaling 500 megawatts
(MW) (2 units × 250 MW units) of
generating capacity; and (6) a 7-milelong, 230 kilovolt (kV) transmission line
that would connect from the switchyard
with an existing 230 kV interconnection
east of the project area. The project’s
annual energy output would vary
between 600 and 1,500 gigawatt hours.
Applicant Contact: Mr. Donald
Thompson, INCA Engineers, Inc., 400,
112th Ave. NE., Suite 400, Bellevue,
WA 98004; phone (425) 653–1000.
FERC Contact: Brian Csernak; phone:
(202) 502–6144.
Deadline for filing comments, motions
to intervene, competing applications
(without notices of intent), or notices of
VerDate Mar<15>2010
22:00 Dec 23, 2011
Jkt 226001
intent to file competing applications: 60
days from the issuance of this notice.
Competing applications and notices of
intent must meet the requirements of 18
CFR 4.36. Comments, motions to
intervene, notices of intent, and
competing applications may be filed
electronically via the Internet. See 18
CFR 385.2001(a)(1)(iii) and the
instructions on the Commission’s Web
site https://www.ferc.gov/docs-filing/
efiling.asp. Commenters can submit
brief comments up to 6,000 characters,
without prior registration, using the
eComment system at https://
www.ferc.gov/docs-filing/
ecomment.asp. You must include your
name and contact information at the end
of your comments. For assistance,
please contact FERC Online Support at
FERCOnlineSupport@ferc.gov or toll
free at 1–(866) 208–3676, or for TTY,
(202) 502–8659. Although the
Commission strongly encourages
electronic filing, documents may also be
paper-filed. To paper-file, mail an
original and seven copies to: Kimberly
D. Bose, Secretary, Federal Energy
Regulatory Commission, 888 First Street
NE., Washington, DC 20426.
More information about this project,
including a copy of the application, can
be viewed or printed on the ‘‘eLibrary’’
link of Commission’s Web site at
https://www.ferc.gov/docs-filing/
elibrary.asp. Enter the docket number
(P–14328–000) in the docket number
field to access the document. For
assistance, contact FERC Online
Support.
Dated: December 20, 2011.
Kimberly D. Bose,
Secretary.
[FR Doc. 2011–33073 Filed 12–23–11; 8:45 am]
BILLING CODE 6717–01–P
DEPARTMENT OF ENERGY
Federal Energy Regulatory
Commission
[Docket No. CP12–22–000]
Dominion Transmission, Inc; Notice of
Request Under Blanket Authorization
Take notice that on December 5, 2011,
Dominion Transmission, Inc (DTI), 701
East Cary Street, Richmond, VA 23219,
filed in Docket No. CP12–22–000, a
prior notice request under its blanket
certificate issued in Docket No. CP82–
537–000 pursuant to sections 157.205,
157.208 and 157.210 of the
Commission’s regulations under the
Natural Gas Act (NGA) to replace
certain pipeline facilities located in
Gilmer County, West Virginia, all as
PO 00000
Frm 00059
Fmt 4703
Sfmt 9990
more fully set forth in the application,
which is on file with the Commission
and open to public inspection. The
filing may also be viewed on the web at
https://www.ferc.gov using the
‘‘eLibrary’’ link. Enter the docket
number excluding the last three digits in
the docket number field to access the
document. For assistance, contact FERC
at FERCOnlineSupport@ferc.gov or call
toll-free, (866) 208–3676 or TTY, (202)
502–8659.
Specifically, DTI proposes to: (1)
Replace approximately 14.98 miles of
it’s existing multi-diameter (12, 14, and
16-inch) TL–264 pipeline in Calhoun
and Gilmer Counties, West Virginia
with 16-inch diameter pipe; (2)
construct approximately 735 feet of 8inch diameter TL–369 Ext. 2 receiver
pipeline facilities; and (3) construct two
new pipeline launcher/receivers and
one new pipeline receiver as necessary
to perform pigging operations on the
pipeline. DTI estimates the total cost of
the subject facilities is $16.2 million.
Any questions regarding this Prior
Notice should be directed to Brad
Knisley, Regulatory and Certificates
Analyst III, Dominion Transmission,
Inc., 701 East Cary Street, Richmond,
VA 23219, telephone no. (804) 771–
4416, facsimile no. (804) 771–4804 and
Email: Brad.A.Knisley@dom.com.
Any person may, within 60 days after
the issuance of the instant notice by the
Commission, file pursuant to Rule 214
of the Commission’s Procedural Rules
(18 CFR 385.214) a motion to intervene
or notice of intervention. Any person
filing to intervene or the Commission’s
staff may, pursuant to section 157.205 of
the Commission’s regulations under the
NGA (18 CFR 157.205) file a protest to
the request. If no protest is filed within
the time allowed therefore, the proposed
activity shall be deemed to be
authorized effective the day after the
time allowed for protest. If a protest is
filed and not withdrawn within 30 days
after the time allowed for filing a
protest, the instant request shall be
treated as an application for
authorization pursuant to section 7 of
the NGA.
The Commission strongly encourages
electronic filings of comments, protests,
and interventions via the internet in lieu
of paper. See 18 CFR 385.2001(a) (1) (iii)
and the instructions on the
Commission’s Web site (www.ferc.gov)
under the ‘‘e-Filing’’ link.
Dated: December 19, 2011.
Kimberly D. Bose,
Secretary.
[FR Doc. 2011–32990 Filed 12–23–11; 8:45 am]
BILLING CODE 6717–01–P
E:\FR\FM\27DEN1.SGM
27DEN1
Agencies
[Federal Register Volume 76, Number 248 (Tuesday, December 27, 2011)]
[Notices]
[Page 80926]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2011-32990]
-----------------------------------------------------------------------
DEPARTMENT OF ENERGY
Federal Energy Regulatory Commission
[Docket No. CP12-22-000]
Dominion Transmission, Inc; Notice of Request Under Blanket
Authorization
Take notice that on December 5, 2011, Dominion Transmission, Inc
(DTI), 701 East Cary Street, Richmond, VA 23219, filed in Docket No.
CP12-22-000, a prior notice request under its blanket certificate
issued in Docket No. CP82-537-000 pursuant to sections 157.205, 157.208
and 157.210 of the Commission's regulations under the Natural Gas Act
(NGA) to replace certain pipeline facilities located in Gilmer County,
West Virginia, all as more fully set forth in the application, which is
on file with the Commission and open to public inspection. The filing
may also be viewed on the web at https://www.ferc.gov using the
``eLibrary'' link. Enter the docket number excluding the last three
digits in the docket number field to access the document. For
assistance, contact FERC at FERCOnlineSupport@ferc.gov or call toll-
free, (866) 208-3676 or TTY, (202) 502-8659.
Specifically, DTI proposes to: (1) Replace approximately 14.98
miles of it's existing multi-diameter (12, 14, and 16-inch) TL-264
pipeline in Calhoun and Gilmer Counties, West Virginia with 16-inch
diameter pipe; (2) construct approximately 735 feet of 8-inch diameter
TL-369 Ext. 2 receiver pipeline facilities; and (3) construct two new
pipeline launcher/receivers and one new pipeline receiver as necessary
to perform pigging operations on the pipeline. DTI estimates the total
cost of the subject facilities is $16.2 million.
Any questions regarding this Prior Notice should be directed to
Brad Knisley, Regulatory and Certificates Analyst III, Dominion
Transmission, Inc., 701 East Cary Street, Richmond, VA 23219, telephone
no. (804) 771-4416, facsimile no. (804) 771-4804 and Email:
Brad.A.Knisley@dom.com.
Any person may, within 60 days after the issuance of the instant
notice by the Commission, file pursuant to Rule 214 of the Commission's
Procedural Rules (18 CFR 385.214) a motion to intervene or notice of
intervention. Any person filing to intervene or the Commission's staff
may, pursuant to section 157.205 of the Commission's regulations under
the NGA (18 CFR 157.205) file a protest to the request. If no protest
is filed within the time allowed therefore, the proposed activity shall
be deemed to be authorized effective the day after the time allowed for
protest. If a protest is filed and not withdrawn within 30 days after
the time allowed for filing a protest, the instant request shall be
treated as an application for authorization pursuant to section 7 of
the NGA.
The Commission strongly encourages electronic filings of comments,
protests, and interventions via the internet in lieu of paper. See 18
CFR 385.2001(a) (1) (iii) and the instructions on the Commission's Web
site (www.ferc.gov) under the ``e-Filing'' link.
Dated: December 19, 2011.
Kimberly D. Bose,
Secretary.
[FR Doc. 2011-32990 Filed 12-23-11; 8:45 am]
BILLING CODE 6717-01-P