Slatersville Hydro, LLC; Notice of Availability of Environmental Assessment, 45625 [2010-18973]
Download as PDF
Federal Register / Vol. 75, No. 148 / Tuesday, August 3, 2010 / Notices
erowe on DSK5CLS3C1PROD with NOTICES
above according to the test procedures
for electric refrigerator-freezers
prescribed by DOE at 10 CFR part 430,
appendix A1, except that, for the
Samsung products listed in paragraph
(2) only:
(A) The following definition is added
at the end of Section 1:
1.13 Variable anti-sweat heater
control means an anti-sweat heater
where power supplied to the device is
determined by an operating condition
variable(s) and/or ambient condition
variable(s).
(B) Section 2.2 is revised to read as
follows:
2.2 Operational conditions. The
electric refrigerator or electric
refrigerator-freezer shall be installed and
its operating conditions maintained in
accordance with HRF–1–1979, section
7.2 through section 7.4.3.3, except that
the vertical ambient temperature
gradient at locations 10 inches (25.4 cm)
out from the centers of the two sides of
the unit being tested is to be maintained
during the test. Unless shields or baffles
obstruct the area, the gradient is to be
maintained from 2 inches (5.1 cm)
above the floor or supporting platform
to a height 1 foot (30.5 cm) above the
unit under test. Defrost controls are to
be operative. The anti-sweat heater
switch is to be off during one test and
on during the second test. In the case of
an electric refrigerator-freezer equipped
with variable anti-sweat heater control,
the result of the second test will be
derived by performing the calculation
described in 6.2.3. Other exceptions are
noted in 2.3, 2.4, and 5.1 below.
(C) New section 6.2.3 is inserted after
section 6.2.2.2.
6.2.3 Variable anti-sweat heater
control test. The energy consumption of
an electric refrigerator-freezer with a
variable anti-sweat heater control in the
on position (Eon), expressed in kilowatthours per day, shall be calculated
equivalent to:
EON = E + (Correction Factor)
where E is determined by sections
6.2.1.1, 6.2.1.2, 6.2.2.1, or 6.2.2.2,
whichever is appropriate, with the antisweat heater switch in the off position.
Correction Factor = (Anti-sweat Heater
Power × System-loss Factor) × (24
hrs/1 day) × (1 kW/1,000 W)
Where:
Anti-sweat Heater Power
= A1 * (Heater Watts at 5%RH)
+ A2 * (Heater Watts at 15%RH)
+ A3 * (Heater Watts at 25%RH)
+ A4 * (Heater Watts at 35%RH)
+ A5 * (Heater Watts at 45%RH)
+ A6 * (Heater Watts at 55%RH)
+ A7 * (Heater Watts at 65%RH)
+ A8 * (Heater Watts at 75%RH)
VerDate Mar<15>2010
14:41 Aug 02, 2010
Jkt 220001
+ A9 * (Heater Watts at 85%RH)
+ A10 * (Heater Watts at 95%RH)
where A1–A10 are defined in the following
table:
A1
A2
A3
A4
A5
=
=
=
=
=
0.034
0.211
0.204
0.166
0.126
A6 = 0.119
A7 = 0.069
A8 = 0.047
A9 = 0.008
A10 = 0.015
Heater Watts at a specific relative
humidity = the nominal watts used by
all heaters at that specific relative
humidity, 72 °F ambient, and DOE
reference temperatures of fresh food
(FF) average temperature of 45 °F and
freezer (FZ) average temperature of 5 °F.
System-loss Factor = 1.3
(4) Representations. Samsung may
make representations about the energy
use of its adaptive control anti-sweat
heater refrigerator-freezer products for
compliance, marketing, or other
purposes only to the extent that such
products have been tested in accordance
with the provisions outlined above and
such representations fairly disclose the
results of such testing.
(5) This waiver shall remain in effect
consistent with the provisions of 10 CFR
430.27(m).
(6) This waiver is issued on the
condition that the statements,
representations, and documentary
materials provided by the petitioner are
valid. DOE may revoke or modify this
waiver at any time if it determines the
factual basis underlying the petition for
waiver is incorrect, or the results from
the alternate test procedure are
unrepresentative of the basic models’
true energy consumption characteristics.
Issued in Washington, DC, on July 27, 2010.
Cathy Zoi,
Assistant Secretary, Energy Efficiency and
Renewable Energy.
[FR Doc. 2010–19022 Filed 8–2–10; 8:45 am]
BILLING CODE 6450–01–P
DEPARTMENT OF ENERGY
Federal Energy Regulatory
Commission
the application for exemption from
licensing for the Slatersville
Hydroelectric Project, to be located on
the Branch River, in Providence County,
Rhode Island, and has prepared an
Environmental Assessment (EA). In the
EA, Commission staff analyze the
potential environmental effects of the
project and conclude that issuing an
exemption for the project, with
appropriate environmental measures,
would not constitute a major Federal
action significantly affecting the quality
of the human environment.
A copy of the EA is on file with the
Commission and is available for public
inspection. The EA may also be viewed
on the Commission’s Web site at
https://www.ferc.gov using the ‘‘eLibrary’’
link. Enter the docket number excluding
the last three digits in the docket
number field to access the document.
For assistance, contact FERC Online
Support at
FERCOnlineSupport@ferc.gov or tollfree at 1–866–208–3676, or for TTY,
(202) 502–8659.
Any comments should be filed within
30 days from the date of this notice.
Comments may be filed electronically
via the Internet. See 18 CFR
385.2001(a)(1)(iii) and the instructions
on the Commission’s Web site (https://
www.ferc.gov/docs-filing/ferconline.asp)
under the ‘‘eFiling’’ link. For a simpler
method of submitting text only
comments, click on ‘‘eComment.’’ For
assistance, please contact FERC Online
Support at
FERCOnlineSupport@ferc.gov; call tollfree at (866) 208–3676; or, for TTY,
contact (202) 502–8659. Although the
Commission strongly encourages
electronic filing, documents may also be
paper-filed. To paper-file, mail an
original and eight copies to: Kimberly D.
Bose, Secretary, Federal Energy
Regulatory Commission, 888 First
Street, NE., Washington, DC 20426.
Please affix Project No. 13356–000 to all
comments. For further information,
contact Tom Dean at (202) 502–6041.
Kimberly D. Bose,
Secretary.
[Project No. 13356–000–RI]
Slatersville Hydro, LLC; Notice of
Availability of Environmental
Assessment
[FR Doc. 2010–18973 Filed 8–2–10; 8:45 am]
BILLING CODE 6717–01–P
July 27, 2010.
In accordance with the National
Environmental Policy Act of 1969 and
the Federal Energy Regulatory
Commission’s regulations, 18 CFR part
380 (Order No. 486, 52 FR 47879), the
Office of Energy Projects has reviewed
PO 00000
Frm 00026
Fmt 4703
Sfmt 9990
45625
E:\FR\FM\03AUN1.SGM
03AUN1
Agencies
[Federal Register Volume 75, Number 148 (Tuesday, August 3, 2010)]
[Notices]
[Page 45625]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2010-18973]
-----------------------------------------------------------------------
DEPARTMENT OF ENERGY
Federal Energy Regulatory Commission
[Project No. 13356-000-RI]
Slatersville Hydro, LLC; Notice of Availability of Environmental
Assessment
July 27, 2010.
In accordance with the National Environmental Policy Act of 1969
and the Federal Energy Regulatory Commission's regulations, 18 CFR part
380 (Order No. 486, 52 FR 47879), the Office of Energy Projects has
reviewed the application for exemption from licensing for the
Slatersville Hydroelectric Project, to be located on the Branch River,
in Providence County, Rhode Island, and has prepared an Environmental
Assessment (EA). In the EA, Commission staff analyze the potential
environmental effects of the project and conclude that issuing an
exemption for the project, with appropriate environmental measures,
would not constitute a major Federal action significantly affecting the
quality of the human environment.
A copy of the EA is on file with the Commission and is available
for public inspection. The EA may also be viewed on the Commission's
Web site at https://www.ferc.gov using the ``eLibrary'' link. Enter the
docket number excluding the last three digits in the docket number
field to access the document. For assistance, contact FERC Online
Support at FERCOnlineSupport@ferc.gov or toll-free at 1-866-208-3676,
or for TTY, (202) 502-8659.
Any comments should be filed within 30 days from the date of this
notice. Comments may be filed electronically via the Internet. See 18
CFR 385.2001(a)(1)(iii) and the instructions on the Commission's Web
site (https://www.ferc.gov/docs-filing/ferconline.asp) under the
``eFiling'' link. For a simpler method of submitting text only
comments, click on ``eComment.'' For assistance, please contact FERC
Online Support at FERCOnlineSupport@ferc.gov; call toll-free at (866)
208-3676; or, for TTY, contact (202) 502-8659. Although the Commission
strongly encourages electronic filing, documents may also be paper-
filed. To paper-file, mail an original and eight copies to: Kimberly D.
Bose, Secretary, Federal Energy Regulatory Commission, 888 First
Street, NE., Washington, DC 20426. Please affix Project No. 13356-000
to all comments. For further information, contact Tom Dean at (202)
502-6041.
Kimberly D. Bose,
Secretary.
[FR Doc. 2010-18973 Filed 8-2-10; 8:45 am]
BILLING CODE 6717-01-P