Mark Edward Leyse; Receipt of Petition for Rulemaking, 28902-28906 [E7-9910]
Download as PDF
28902
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Proposed Rules
current regulation does not describe the
compliance review and appeals
processes in a single, cohesive section.
A unified compliance section may
improve the regulation.
(f) Revising the portions of the
regulation regarding evaluation
[currently found at § 1485.20(c)] to
include requirements for country
progress reports and success stories.
(g) Eliminating the Export Incentive
Program/Market Access Program (EIP/
MAP) subcomponent. FAS does not
currently operate the EIP/MAP
subcomponent and is considering
removing reference to the
subcomponent from the regulation.
III. With respect to risk management,
FAS is soliciting comments regarding
the mitigation of the risk inherent to
reimbursing third party contracting
expenses and brand participant
activities with program funds. This
could include improved accounting
controls, insurance against fraud,
bonding employees, or other risk
management tools.
IV. In addition, FAS requests
comments on any other aspect of the
program set forth at 7 CFR part 1485
which commenters believe should be
addressed in any future amendment of
the regulation.
Dated: May 10, 2007.
W. Kirk Miller,
Acting Administrator, Foreign Agricultural
Service, and Vice President, Commodity
Credit Corporation.
[FR Doc. 07–2552 Filed 5–22–07; 8:45 am]
BILLING CODE 3410–10–M
DEPARTMENT OF AGRICULTURE
Animal and Plant Health Inspection
Service
9 CFR Part 1
[Docket No. APHIS–2006–0158]
Animal Welfare; Petition for
Rulemaking
Animal and Plant Health
Inspection Service, USDA.
ACTION: Notice of petition and request
for comments; extension of comment
period.
cprice-sewell on PROD1PC71 with PROPOSALS
AGENCY:
SUMMARY: We are extending the
comment period for our notice of
petition and request for comments
concerning the definition of Class ‘‘B’’
licensee in the Animal Welfare Act
regulations. This action will allow
interested persons additional time to
prepare and submit comments.
VerDate Aug<31>2005
15:44 May 22, 2007
Jkt 211001
We will consider all comments
that we receive on or before July 9,
2007.
DATES:
You may submit comments
by either of the following methods:
• Federal eRulemaking Portal: Go to
https://www.regulations.gov, select
‘‘Animal and Plant Health Inspection
Service’’ from the agency drop-down
menu, then click ‘‘Submit.’’ In the
Docket ID column, select APHIS–2006–
0158 to submit or view public
comments and to view supporting and
related materials available
electronically. Information on using
Regulations.gov, including instructions
for accessing documents, submitting
comments, and viewing the docket after
the close of the comment period, is
available through the site’s ‘‘User Tips’’
link.
• Postal Mail/Commercial Delivery:
Please send four copies of your
comment (an original and three copies)
to Docket No. APHIS–2006–0158,
Regulatory Analysis and Development,
PPD, APHIS, Station 3A–03.8, 4700
River Road Unit 118, Riverdale, MD
20737–1238. Please state that your
comment refers to Docket No. APHIS–
2006–0158.
Reading Room: You may read any
comments that we receive on Docket
No. APHIS–2006–0158 in our reading
room. The reading room is located in
room 1141 of the USDA South Building,
14th Street and Independence Avenue
SW., Washington, DC. Normal reading
room hours are 8 a.m. to 4:30 p.m.,
Monday through Friday, except
holidays. To be sure someone is there to
help you, please call (202) 690–2817
before coming.
Other Information: Additional
information about APHIS and its
programs is available on the Internet at
https://www.aphis.usda.gov.
FOR FURTHER INFORMATION CONTACT: Dr.
Jerry DePoyster, Senior Veterinary
Medical Officer, Animal Care, APHIS,
4700 River Road Unit 84, Riverdale, MD
20737–1234; (301) 734–7586.
SUPPLEMENTARY INFORMATION: On April
10, 2007, we published in the Federal
Register (72 FR 17814, Docket No.
APHIS–2006–0158) a notice of petition
and request for comments. That
document notified the public that the
Animal and Plant Health Inspection
Service had received a petition from
The Hunte Corporation requesting that
we replace the definition of Class ‘‘B’’
licensee in the Animal Welfare Act
regulations with four new categories of
licensees: Pet distributor, exhibitor
animal distributor, laboratory animal
distributor, and other distributor.
ADDRESSES:
PO 00000
Frm 00008
Fmt 4702
Sfmt 4702
Comments on the notice were
required to be received on or before June
11, 2007. We are extending the
comment period on Docket No. APHIS–
2006–0158 for an additional 30 days.
This action will allow interested
persons additional time to prepare and
submit comments.
Authority: 7 U.S.C. 2131–2159; 7 CFR 2.22,
2.80, and 371.7.
Done in Washington, DC, this 17th day of
May 2007.
Kevin Shea,
Acting Administrator, Animal and Plant
Health Inspection Service.
[FR Doc. E7–9901 Filed 5–22–07; 8:45 am]
BILLING CODE 3410–34–P
NUCLEAR REGULATORY
COMMISSION
10 CFR Part 50
[Docket No. PRM–50–84]
Mark Edward Leyse; Receipt of
Petition for Rulemaking
Nuclear Regulatory
Commission.
ACTION: Petition for rulemaking; notice
of receipt.
AGENCY:
SUMMARY: The Nuclear Regulatory
Commission (NRC) has received and
requests public comment on a petition
for rulemaking dated March 15, 2007,
filed by Mark Edward Leyse. The
petition has been docketed by the NRC
and has been assigned Docket No. PRM–
50–84. The petitioner is requesting that
the NRC amend the regulations that
govern domestic licensing of production
and utilization facilities to require that
nuclear power facilities be operated to
limit the thickness of crud (corrosion
products) layers and/or the thickness of
oxide layers on fuel rod cladding
surfaces. The petitioner also requests
that the requirements pertaining to
Emergency Core Cooling System (ECCS)
evaluation models be amended to
require that the steady-state temperature
distribution and stored energy in reactor
fuel at the onset of a postulated loss-ofcoolant accident (LOCA) be calculated
by factoring in the role that the thermal
resistance of crud and/or oxide layers
on cladding plays in increasing the
stored energy in the fuel. Lastly, the
petitioner requests that the acceptance
criteria for emergency core cooling
systems for light-water nuclear power
reactors be amended to stipulate a
maximum allowable percentage of
hydrogen content in cladding of fuel
rods.
E:\FR\FM\23MYP1.SGM
23MYP1
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Proposed Rules
Submit comments by August 6,
2007. Comments received after this date
will be considered if it is practical to do
so, but assurance of consideration
cannot be given except as to comments
received on or before this date.
ADDRESSES: You may submit comments
by any one of the following methods.
Please include the following number
(PRM–50–84) in the subject line of your
comments. Comments on petitions
submitted in writing or in electronic
form will be made available for public
inspection. Because your comments will
not be edited to remove any identifying
or contact information, the NRC
cautions you against including personal
information such as social security
numbers and birth dates in your
submission.
Mail comments to: Secretary, U.S.
Nuclear Regulatory Commission,
Washington, DC 20555. Attention:
Rulemaking and Adjudications staff.
E-mail comments to: SECY@nrc.gov. If
you do not receive a reply e-mail
confirming that we have received your
comments, contact us directly at (301)
415–1966. You may also submit
comments via the NRC’s rulemaking
Web site at https://ruleforum.llnl.gov.
Address comments about our
rulemaking Web site to Carol Gallagher,
(301) 415–5905; (e-mail cag@nrc.gov).
Comments can also be submitted via the
Federal eRulemaking Portal
http:www.regulations.gov.
Hand deliver comments to: 11555
Rockville Pike, Rockville, Maryland,
between 7:30 a.m. and 4:15 p.m. on
Federal workdays.
Publicly available documents related
to this petition may be viewed
electronically on the public computers
located at the NRC Public Document
Room (PDR), O1 F21, One White Flint
North, 11555 Rockville Pike, Rockville,
Maryland. The PDR reproduction
contractor will copy documents for a
fee. Selected documents, including
comments, may be viewed and
downloaded electronically via the NRC
rulemaking Web site at https://
ruleforum.llnl.gov.
Publically available documents
created or received at the NRC after
November 1, 1999 are also available
electronically at the NRC’s Electronic
Reading Room at https://www.nrc.gov/
reading-rm/adams.html. From this site,
the public can gain entry into the NRC’s
Agencywide Documents Access and
Management System (ADAMS), which
provides text and image files of NRC’s
public documents. If you do not have
access to ADAMS or if there are
problems in accessing the documents
located in ADAMS, contact the NRC
cprice-sewell on PROD1PC71 with PROPOSALS
DATES:
VerDate Aug<31>2005
15:44 May 22, 2007
Jkt 211001
PDR Reference staff at 1–800–397–4209,
301–415–4737 or by e-mail to
pdr@nrc.gov.
For a copy of the petition, write to
Michael T. Lesar, Chief, Rulemaking,
Directives and Editing Branch, Division
of Administrative Services, Office of
Administration, U.S. Nuclear Regulatory
Commission, Washington, DC 20555–
0001.
FOR FURTHER INFORMATION CONTACT:
Michael T. Lesar, Office of
Administration, U.S. Nuclear Regulatory
Commission, Washington, DC 20555.
Telephone: 301–415–7163 or Toll-Free:
1–800–368–5642 or E-mail:
MTL@NRC.Gov.
SUPPLEMENTARY INFORMATION:
Background
The NRC has received a petition for
rulemaking dated March 15, 2007,
submitted by Mark Edward Leyse
(petitioner). The petitioner requests that
the NRC amend 10 CFR part 50,
‘‘Domestic Licensing of Production and
Utilization Facilities.’’ Specifically, the
petitioner requests that all holders of
operating licenses for nuclear power
plants be required to operate such
plants at operating conditions (e.g.,
levels of power production, fuel cycle
lengths, and light-water coolant
chemistries) necessary to effectively
limit the thickness of crud (corrosion
products) layers and/or oxide layers on
fuel rod cladding surfaces. The
petitioner believes that new regulations
are needed for reactor-operation
parameters, uranium-oxide and mixedoxide fuel and cladding, in order to
ensure that cladding is free of unsafe
thicknesses of crud and/or oxide, which
in turn would help ensure that nuclear
power plants operate in compliance
with 10 CFR 50.46(b). 10 CFR 50.46(b)
stipulates that the calculated peak
cladding temperature (PCT) must not
exceed 2200°F in the event of a loss-ofcoolant accident (LOCA). The petitioner
also requests that 10 CFR part 50,
Appendix K, ‘‘ECCS Evaluation
Models’’ be amended to require that the
steady-state temperature distribution
and stored energy in the fuel at the
onset of a postulated LOCA be
calculated by factoring in the role that
the thermal resistance of crud and/or
oxide layers on cladding plays in
increasing the stored energy in the fuel.
Lastly, the petitioner requests that
§ 50.46 be amended to stipulate a
maximum allowable percentage of
hydrogen content in fuel cladding.
The NRC has determined that the
petition meets the threshold sufficiency
requirements for a petition for
rulemaking under 10 CFR 2.802. The
PO 00000
Frm 00009
Fmt 4702
Sfmt 4702
28903
petition has been docketed as PRM–50–
84. The NRC is soliciting public
comment on the petition for rulemaking.
Discussion of the Petition
The petitioner states that layers of
crud and oxide on cladding surfaces of
nuclear fuel rods could cause the
temperature of fuel rods to increase up
to 300 °F to 600 °F during power plant
operations. The petitioner also states
that during a LOCA, the thermal
resistance of insulating layers of crud
and oxide on cladding, and increased
fuel temperatures will cause the PCT to
be higher than if the cladding were
clean. The petitioner believes that if a
large break (LB) LOCA occurred at a
nuclear power plant that operated with
heavy crud and oxide layers, there is a
high probability that the PCT would
exceed the 2200 °F limit in § 50.46(b)(1).
The petitioner states that increased
hydrogen content in cladding
contributes to cladding embrittlement.
The petitioner believes that § 50.46
should also be amended to specify a
maximum allowable percentage of
hydrogen in cladding.
The petitioner states that in 2001, the
Indian Point Unit 2 facility had a PCT
of 2188 °F during a computer simulated
LB LOCA. The petitioner believes that if
heavy crud and oxide layers were
present and included in the calculation,
it is ‘‘highly probable’’ the calculated
PCT would have exceeded the 2200 °F
limit, perhaps by hundreds of degrees
Fahrenheit. The petitioner states that if
the 2200 °F limit was exceeded during
actual operation, the cladding could
lose its physical integrity and result in
a core meltdown that would release
radioactive material and contaminate
the environment. The petitioner states
that in 1995, the Three Mile Island Unit
1 facility (TMI–1) operated with crud
deposits on the surface of fuel rods that
raised the cladding temperature by 180
to 270 °F or greater over the typical
operating temperature of 346 °C during
Cycle 10. The petitioner believes that if
an actual LB LOCA had occurred at
TMI–1, the crud and oxide layers on the
cladding would have caused the PCT to
exceed 2200 °F.
The petitioner states that because
corrosion is not detected during plant
operation, a significant length of time
passes before corrosion progresses
enough to perforate cladding and cause
an increase in ‘‘offgas’’ activity meaning
that heavily corroded fuel rods are often
operated at full power for significant
periods of time and could cause the
cladding to fracture during the reflood
period and lose structural integrity. The
petitioner concludes that this could
compromise the structural soundness
E:\FR\FM\23MYP1.SGM
23MYP1
cprice-sewell on PROD1PC71 with PROPOSALS
28904
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Proposed Rules
and the ability to keep the core cooled
and illustrates the impact that the
thermal resistance of heavy layers of
oxide and crud on cladding would have
during a LOCA.
The petitioner cites a September 30,
2003, Advisory Committee on Reactor
Safeguards (ACRS) meeting transcript
stating that the thickness of crud
deposited on the cladding during
pressurized water reactor (PWR) plant
operation is often not known because ‘‘a
great deal of PWR crud comes off the
cladding during reactor shutdown.’’ The
petitioner notes that crud deposits on
cladding in PWRs have been measured
at up to 125µm thick. The ACRS found
that a crud layer with steam blanketing
would have ‘‘extremely poor
conductivity’’ and that crud is ‘‘difficult
to characterize’’ because its thermal
conductivities ‘‘depend on [its]
morpholog[ies].’’
The petitioner also cites an Electric
Power Research Institute (EPRI) study to
be completed in 2008 that will attempt
‘‘to determine the effect of tenacious
crud on fuel surface heat transfer.’’ The
petitioner notes that this study is for
crud in a boiling water reactor (BWR)
but believes the results can also be
applied to PWRs.
The petitioner also notes that the EPRI
study found that Zirconium dioxide
(ZrO2) has a low thermal conductivity
and is used industrially as an insulating
material. The petitioner cites an EPRIsponsored study entitled, ‘‘Taming the
Crud Problem: The Evolution,’’
presented at the Advances in Nuclear
Fuel Management II Conference in
October 2003 which states that: ‘‘Oxide
can form, with or without the benefit of
crud, in the presence of sustained
cladding temperatures. Like crud,
formation of an oxide layer inhibits heat
transfer causing accelerated corrosion
which can potentially lead to fuel
failure.’’
The petitioner describes a fuel rod
that failed at TMI–1 during Cycle 10
that may have had about a 200µm-thick
layer of crud and oxide. The petitioner
believes that if a LB LOCA occurred
during this fuel cycle, the layer of crud
and oxide would have inhibited
effective heat transfer and likely caused
the PCT to exceed 2200 °F, possibly
causing a meltdown. The petitioner also
reiterates that in 2001, the Indian Point
Unit 2 facility had a PCT of 2188 °F in
a computer simulated LB LOCA. The
petitioner believes that if Indian Point
Unit 2 had cladding conditions similar
to those of TMI–1 Cycle 10, it is highly
probable the PCT would also have been
greater than 2200 °F. The petitioner
states that TMI–1 is not the only PWR
to experience crud-induced corrosion
VerDate Aug<31>2005
15:44 May 22, 2007
Jkt 211001
failures. In 1997, the Palo Verde Unit 2
and Seabrook facilities both had the
same problem.
The petitioner cites NUREG–1230,
‘‘Compendium of ECCS Research for
Realistic LOCA Analysis’’ and states
that the stored energy in the fuel
increases because cladding encased in
heavy amounts of crud and oxide
cannot transfer heat efficiently to
coolant during the blowdown phase of
the event. The petitioner states that the
increased stored energy caused by heavy
crud and oxide layers on fuel cladding
and the delay in the transfer of the heat
to the coolant cause the cladding to be
subjected to extremely high
temperatures for much longer than if the
cladding was clean (free of crud and
oxidation) at the onset of the LOCA. The
petitioner believes that this would result
in more degradation of the fuel and
embrittlement of cladding. The
petitioner also states that when the
cladding reacts with steam, an
exothermic reaction occurs that
generates additional heat on the
cladding.
The petitioner cites an ACRS meeting
transcript from February 2, 2007, in
which an NRC staff member explained
that a basic LOCA transient calculation
includes an oxidation limit and involves
time and temperature. The petitioner
also notes that NUREG–1230 states that
embrittled cladding can fragment upon
contact with emergency cooling water in
a severe accident. The embrittlement is
a function of temperature, time, the
supply of steam and zircaloy, and can
lead to the loss of effective cooling,
making it relevant to fuel rod safety. The
petitioner also notes that NUREG–1230
also states, ‘‘[the] amount of residual
thermal energy [in the fuel rod]
influences the time required to quench
the reactor core with emergency cooling
water [emphasis added].’’
The petitioner states that absorption
of hydrogen would also contribute to a
loss of cladding ductility during a LOCA
along with cladding degradation and
massive oxidation. He cites a failed fuel
rod from the TMI–1, Cycle 10 event
when hydrogen absorption caused
hydrided material to break away from
the outer portions of the cladding. The
petitioner believes that the effects of
increased stored energy due to a heavy
crud layer in the fuel and the severity
of cladding oxidation, embrittlement,
and resulting fuel degradation during an
actual event would be substantially
greater than in an ECCS calculation
based on clean cladding.
The petitioner also states that little or
no evidence exists that crud has ever
been properly factored into PCT
calculations for postulated LOCAs. He
PO 00000
Frm 00010
Fmt 4702
Sfmt 4702
cites a June 17, 2003, Idaho National
Engineering and Environmental
Laboratory document that he believes
stated that crud has not been applied to
severe accident codes because it has not
been demonstrated to be necessary and
that users have not chosen to consider
effects of crud. The petitioner also cites
the 2002 annual report on ECCS
evaluation from the Callaway facility
that he believes proves that ‘‘little
attention’’ was placed on effects of
heavy crud on thermal resistance. The
petitioner states that most cladding that
experienced crud-induced corrosion
failures recently at PWRs involved highpower, one-cycle fuel. He cites the TMI–
1, Cycle 10 and Callaway, Cycle 6
events as examples and notes that the
effects of crud can occur quickly. The
cladding perforation at TMI–1 was
detected only 121 days into the cycle.
The petitioner states that the values of
the stored energy in BOL fuel or fuel
with burnups between 30 to 35 GWd/
MTU are used to calculate PCTs during
postulated LOCAs. The petitioner also
believes it is significant that the stored
energy of fuel sheathed in cladding with
heavy crud and oxide layers is
substantially higher than fuel of the
same burnup rate sheathed in clean
cladding that he states is used in PCT
calculations performed for postulated
LOCAs and during safety evaluations of
the certification process of newer
designs such as the Westinghouse AP
1000 reactor. The petitioner believes
that the AP 1000 PCTs were not
calculated for the maximum stored
energy that fuel can reach during
operation and that recent experiences
with fuel at TMI–1, Palo Verde Unit 2,
and Seabrook were not considered in
PCT calculations performed during
recent power ‘‘uprates’’ at other nuclear
power facilities.
The petitioner states that axial offset
anomaly (AOA) or crud-induced power
shift (CIPS) are phenomena caused by
crud on cladding and can indicate how
frequently crud affects nuclear power
plant operation. The petitioner also
states that AOA occurs in PWRs when
crud deposits on cladding contain
enough boron to reduce the rate of
fission in the vicinity of the crud. He
cites NRC Information Notice 97–85,
‘‘Effects of Crud Buildup and Boron
Deposition on Power Distribution and
Shutdown Margin’’ that describes how
AOA causes power distribution shifts
toward the bottom of the reactor core as
a result of reduced fission in the upper
reactor core. The petitioner states that
although crud deposits must be at least
35µm thick for AOA to occur, it is
possible that crud deposits thicker than
35µm do not cause AOA because not all
E:\FR\FM\23MYP1.SGM
23MYP1
cprice-sewell on PROD1PC71 with PROPOSALS
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Proposed Rules
crud deposits contain enough boron to
cause this phenomenon. The petitioner
also states that according to a 2002
Department of Energy report on nuclear
energy plant optimization, the thickest
layer of crud measured in a PWR was
125µm thick that caused AOA but not
cladding perforation and that as of 2003,
more than 30 fuel cycles in 16 PWRs
had exhibited AOA.
The petitioner also cites a 2006 EPRI
report that acknowledged that crud has
contributed to AOA at many power
plants since the 1980s because fuel
cycle operation and power up rates have
increased appreciably and that
excessive crud deposits create
operational difficulties. According to a
Westinghouse Electric Company official,
AOAs are detectable and closely
monitored to ensure that adequate
shutdown margins can be maintained.
Also, a plant can be operated at a lower
power level if necessary. The petitioner
cites the TMI–1, Cycle 10 event as an
example that illustrates how low levels
of boron can result in a slight AOA even
though enough crud was present to
induce fuel failure from corrosion. The
petitioner states that if a heavy crud
layer was detected during plant
operation that did not cause an AOA, it
is unlikely that the operation power
level would be reduced because the
thermal resistance of the crud and how
it would raise the PCT during a LOCA
would likely not be considered
problematic.
The petitioner describes what he
believes was a crud-induced cladding
corrosion failure of fuel in a BWR at the
River Bend facility during Cycle 8 from
1998–99. The petitioner states that the
fuel failure occurred when crud nearly
bridged the gap between adjacent rods
and believes it is significant that most of
the failed rods were high-power, onecycle rods (much like the recent
corrosion-induced PWR fuel failures
during the TMI–1 Cycle 10, Palo Verde
Unit 2 Cycle 9, and Seabrook Cycle 5
events). The River Bend Cycle 8 fuel
failure resulted from thick layers of
crud, augmented with copper that
accelerated the oxidation process to
produce a local steam blanketing and
high heat transfer resistance that created
perforations in the fuel cladding
according to the ‘‘Recent GE BWR Fuel
Experience’’ report published in 2000
by the American Nuclear Society and
the NRC inspection report pertaining to
this event. The petitioner concludes that
the combined effects of crud and oxide
layers increased the cladding
temperatures from around 560 °F to
temperatures approaching 1200 °F.
The petitioner states that if a LOCA
had occurred during this event, the PCT
VerDate Aug<31>2005
15:44 May 22, 2007
Jkt 211001
could likely have exceeded the 2200 °F
limit specified in § 50.46. The petitioner
acknowledges that the NRC Licensee
Event Report (LER) 50–458/99–016–00
states that the PCT was calculated to
have been 1700 °F or less and
demonstrates a substantial margin to the
2200 °F limit. However, the petitioner
states that the LER ignores NRC
guidelines for calculating the equivalent
cladding reacted (ECR) and believes that
the PCT would have exceeded 1700 °F
during a LB LOCA. The petitioner states
that in 2000 when this LER was filed
there was not much knowledge about
values for the thermal conductivity of
crud and how crud layers should be
modeled in severe accident codes and
believes this lack of knowledge still
exists in 2007. The petitioner reiterates
there is little or no evidence that crud
has ever been properly factored into
PCT calculations for simulated LOCAs
at nuclear power plants.
The petitioner states that essentially
the same cladding condition occurred
again at the River Bend facility between
October 2001 to March 2003 during the
Cycle 11 refueling event after a GE
Nuclear Energy official had stated that
heavy crud buildup during the Cycle 8
event was unique and had occurred
only once in over 1000 reactor years of
operation. He cites a paper presented at
the 2004 International Meeting on LWR
Fuel presented by the American Nuclear
Society, ‘‘Fuel Failures During Cycle 11
at River Bend.’’ This paper stated that
this fuel rod failure was caused by
accelerated oxidation of the cladding
resulting from unusually heavy deposits
of tenacious crud that diminished heat
transfer in local areas of the cladding
surface. The petitioner notes that the
failures occurred in high power, onecycle rods where heavy crud and oxide
layers were present. The petitioner
believes that the PCT during a LB LOCA
would have exceeded the 2200 °F limit
specified in § 50.46 and means that the
ECCS design basis for River Bend is
non-conservative for calculating the
PCT for a postulated LOCA when heavy
crud and oxide layers exist on cladding.
The petitioner disputes GE Nuclear
Energy’s conclusion that because the
heavy crud deposits on fuel rods at the
River Bend facility occurred at the lower
elevations of the fuel assembly and the
more limiting axial elevations during a
postulated LOCA occur at the upper
elevations of a fuel assembly where at
River Bend the crud characteristics were
normal, the heavy crud deposits would
have no significant effect on the fuel
response to a postulated LOCA. The
petitioner states that the cladding
surface temperatures during the River
Bend events reached 1200 °F, far above
PO 00000
Frm 00011
Fmt 4702
Sfmt 4702
28905
the specified licensing basis of about
578 °F. The petitioner believes that the
higher temperatures due to the heavy
crud and oxide layers would result in
less coolant flow than for clean
cladding, would cause the cladding to
be subjected to extremely high
temperatures for a substantially longer
duration than used in the licensing
basis, and result in more fuel
degradation. The petitioner also believes
that the degradation of fuel and
cladding would further obstruct reflood
coolant flow, delay transfer of stored
energy to the coolant during quench,
and that during a LOCA there would
already be severe cladding degradation,
massive oxidation, and absorption of
hydrogen that would contribute to a loss
of cladding ductility. The petitioner has
concluded that these factors mean that
the River Bend facility operated in
violation of § 50.46(b) during cycles 8
and 11 of refueling. The petitioner also
states that the Browns Ferry facility
operated from April 2001 to March 2003
with thick oxide layers at the upper
elevations of the fuel rods and believes
it is significant that the heavy crud and
oxide layers that caused overheating
and cladding perforations at TMI–1
during cycle 10 were located at upper
elevations of fuel assemblies.
The petitioner cites a 2004 paper, ‘‘An
Integrated Approach to Maximizing
Fuel Reliability’’ stating that a lack of
understanding exists about the interplay
of materials, fuel duty, and water
chemistry variables and reports that
crud or corrosion related fuel failures
occurred at BWRs in six of the years
between 1997 to 2004. The petitioner
also cites an EPRI document, ‘‘2006
Portfolio 41.002 Fuel Reliability’’ which
states that the fuel failure rate has
increased in both BWRs and PWRs
during the last couple of years due to
extended and more aggressive fuel cycle
operation. The petitioner states that
although the nuclear industry observed
that it appeared that nodular corrosion
had been eliminated from BWR fuel
cladding in 2000, by 2004 it had
reemerged at several BWRs. The
petitioner believes this is a result of
increasing fuel duty by extending the
length of fuel cycles and that problems
with crud and oxide will continue
unless the NRC implements regulations
to ensure that BWRs and PWRs do not
operate with high levels of crud and
oxidation on cladding that cause
violations of § 50.46(b).
The petitioner states that Appendix K
to 10 CFR part 50, ‘‘ECCS Evaluation
Models’’ requires stored energy in
nuclear fuel to be calculated to yield the
highest PCT. The petitioner believes
that Appendix K should require thermal
E:\FR\FM\23MYP1.SGM
23MYP1
cprice-sewell on PROD1PC71 with PROPOSALS
28906
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Proposed Rules
conductivity of layers of crud and oxide
to be factored into calculations of the
stored energy in the fuel. The petitioner
states that because a heavy crud layer
would increase the quantity of stored
energy in the fuel, the PCT would also
increase above that of fuel with the
same burnup sheathed in clean
cladding. The petitioner also states that
instructions specified in Appendix K for
calculating the quantity of stored energy
that contains heavy layers of crud and
oxide are non-conservative.
The petitioner notes that values of
stored energy in BOL fuel or fuel with
burnups between 30 to 35 Gwd/MTU
are used to calculate PCTs during
postulated LOCAs. However, the
petitioner cites a January 2007 ACRS
Subcommittee on Materials, Metallurgy,
and Reactor Fuels during which a
Westinghouse official cited data from
LOCA calculations showing that single
cycle fuel with burnups from zero to
approximately 20 or 25 GWd/MTU
yielded the highest PCTs. Westinghouse
also stated that at burnups of about 30
GWd/MTU, there is approximately a ten
percent reduction in achievable power,
which yields PCTs approximately 100
°C lower than those of fresh fuel. The
petitioner concludes it is significant that
an ECCS design based on Appendix K
requirements is non-conservative and
hazardous for calculating the quantity of
stored energy in one-cycle fuel that has
heavy crud on the cladding.
The petitioner states that an increase
in hydrogen content in cladding
contributes to cladding embrittlement.
The petitioner cites an April 4, 2001,
ACRS Reactor Fuels Subcommittee
meeting during which an expert from
Argonne National Laboratory stated that
a reduction of ductility occurs when
hydrogen levels reach about 600 to 700
parts-per-million (ppm) in Zircaloy
cladding. According to the petitioner,
another expert from the Atomic Energy
Research Institute stated that a
threshold for a reduction of ductility in
Zircaloy cladding occurs at even a lower
hydrogen level of about 150 to 200 ppm.
The petitioner also cites the TMI–1
Cycle 10 event that included massive
hydrogen absorption in fuel cladding.
The petitioner notes that hydrogen
content in the cladding of a rod that did
not fail measured 700 ppm at TMI–1
and that this level of hydrogen content
in one-cycle cladding is similar to the
800 ppm level measured in fuel
cladding at the H.B. Robinson, Unit 2
facility, a PWR. The petitioner states
that some of the cladding at TMI–1
Cycle 10 contained levels of hydrogen
that Argonne National Laboratory found
would have caused a loss of cladding
ductility in addition to the
VerDate Aug<31>2005
15:44 May 22, 2007
Jkt 211001
embrittlement resulting from excessive
oxide levels.
The Petitioner’s Proposed Actions
The petitioner states that new
regulations are needed for reactor
operation parameters, uranium-oxide
and mixed-oxide fuel, and fuel cladding
to ensure that cladding does not contain
unsafe amounts of crud and oxide to
help ensure that nuclear power plants
operate in compliance with 10 CFR
50.46(b). The petitioner also states that
nuclear power plant licensees should be
required to factor the thermal resistance
effects of crud and oxide layers on
cladding into calculations of PCTs for
postulated LOCAs at their facilities.
Also, the NRC needs to consider effects
of crud and oxide when reviewing
power plant operations reports under 10
CFR 50.46, and before approving power
uprates at existing facilities and new
nuclear power plant designs, such as the
recently certified Westinghouse AP1000
design.
The petitioner requests that Appendix
K to Part 50 be amended to require that
the steady state temperature distribution
and stored energy in the fuel at the
onset of a postulated LOCA be
calculated by factoring in the role that
the thermal resistance of crud and oxide
layers on cladding plays in increasing
the stored energy in nuclear fuel. The
petitioner also states that Appendix K
should specify instructions to more
accurately calculate the role that
thermal resistance of crud and oxide
layers on cladding plays in determining
the stored energy in the fuel and the
PCT during a postulated LOCA.
Lastly, the petitioner requests that
§ 50.46 be amended to include a
requirement that stipulates a maximum
allowable percentage of hydrogen
content in cladding because there is
extensive evidence that excessive
hydrogen levels and oxidation on
cladding contributes to cladding
embrittlement. The petitioner concludes
that the requested amendments should
also apply to any NRC-approved, bestestimate ECCS evaluations used instead
of Appendix K calculations. The
petitioner believes its requested
amendments would ensure that nuclear
power facilities prevent unsafe amounts
of crud and oxide layers on cladding
from occurring during operation to
reduce risks to plant workers and the
public, and help nuclear power facility
operations to comply with 10 CFR
50.46(b).
Dated at Rockville, Maryland, this 15th day
of May 2007.
PO 00000
Frm 00012
Fmt 4702
Sfmt 4702
For the Nuclear Regulatory Commission.
Annette L. Vietti-Cook,
Secretary of the Commission.
[FR Doc. E7–9910 Filed 5–22–07; 8:45 am]
BILLING CODE 7590–01–P
FEDERAL TRADE COMMISSION
16 CFR Part 24
Guides for Select Leather and Imitation
Leather Products
Federal Trade Commission.
Request for public comments.
AGENCY:
ACTION:
SUMMARY: The Federal Trade
Commission (‘‘FTC’’ or ‘‘Commission’’)
is requesting public comments on its
Guides for Select Leather and Imitation
Leather Products (‘‘Leather Guides’’).
The Commission is soliciting the
comments as part of its systematic
review of all current Commission
regulations and guides.
DATES: Written comments will be
accepted until July 23, 2007.
ADDRESSES: Interested parties are
invited to submit written comments.
Comments should refer to ‘‘Guides for
Select Leather and Imitation Leather
Products, Matter No. P078008’’ to
facilitate the organization of comments.
A comment filed in paper form should
include this reference both in the text
and on the envelope, and should be
mailed or delivered to the following
address: Federal Trade Commission/
Office of the Secretary, Room H–135
(Annex L), 600 Pennsylvania Avenue,
NW., Washington, DC 20580. Comments
containing confidential material,
however, must be filed in paper form,
must be clearly labeled ‘‘Confidential,’’
and must comply with Commission
Rule 4.9(c).1 The FTC is requesting that
any comment filed in paper form be sent
by courier or overnight service, if
possible, because postal mail in the
Washington area and at the Commission
is subject to delay due to heightened
security precautions. Comments filed in
electronic form must be submitted by
accessing the following site: https://
secure.commentworks.com/ftcleatherguides, and following the
instructions on the web-based form.
The FTC Act and other laws the
Commission administers permit the
1 The comment must be accompanied by an
explicit request for confidential treatment,
including the factual and legal basis for the request,
and must identify the specific portions of the
comment to be withheld from the public record.
The request will be granted or denied by the
Commission’s General Counsel, consistent with
applicable law and the public interest. See
Commission Rule 4.9(c), 16 CFR 4.9(c).
E:\FR\FM\23MYP1.SGM
23MYP1
Agencies
[Federal Register Volume 72, Number 99 (Wednesday, May 23, 2007)]
[Proposed Rules]
[Pages 28902-28906]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: E7-9910]
=======================================================================
-----------------------------------------------------------------------
NUCLEAR REGULATORY COMMISSION
10 CFR Part 50
[Docket No. PRM-50-84]
Mark Edward Leyse; Receipt of Petition for Rulemaking
AGENCY: Nuclear Regulatory Commission.
ACTION: Petition for rulemaking; notice of receipt.
-----------------------------------------------------------------------
SUMMARY: The Nuclear Regulatory Commission (NRC) has received and
requests public comment on a petition for rulemaking dated March 15,
2007, filed by Mark Edward Leyse. The petition has been docketed by the
NRC and has been assigned Docket No. PRM-50-84. The petitioner is
requesting that the NRC amend the regulations that govern domestic
licensing of production and utilization facilities to require that
nuclear power facilities be operated to limit the thickness of crud
(corrosion products) layers and/or the thickness of oxide layers on
fuel rod cladding surfaces. The petitioner also requests that the
requirements pertaining to Emergency Core Cooling System (ECCS)
evaluation models be amended to require that the steady-state
temperature distribution and stored energy in reactor fuel at the onset
of a postulated loss-of-coolant accident (LOCA) be calculated by
factoring in the role that the thermal resistance of crud and/or oxide
layers on cladding plays in increasing the stored energy in the fuel.
Lastly, the petitioner requests that the acceptance criteria for
emergency core cooling systems for light-water nuclear power reactors
be amended to stipulate a maximum allowable percentage of hydrogen
content in cladding of fuel rods.
[[Page 28903]]
DATES: Submit comments by August 6, 2007. Comments received after this
date will be considered if it is practical to do so, but assurance of
consideration cannot be given except as to comments received on or
before this date.
ADDRESSES: You may submit comments by any one of the following methods.
Please include the following number (PRM-50-84) in the subject line of
your comments. Comments on petitions submitted in writing or in
electronic form will be made available for public inspection. Because
your comments will not be edited to remove any identifying or contact
information, the NRC cautions you against including personal
information such as social security numbers and birth dates in your
submission.
Mail comments to: Secretary, U.S. Nuclear Regulatory Commission,
Washington, DC 20555. Attention: Rulemaking and Adjudications staff.
E-mail comments to: SECY@nrc.gov. If you do not receive a reply e-
mail confirming that we have received your comments, contact us
directly at (301) 415-1966. You may also submit comments via the NRC's
rulemaking Web site at https://ruleforum.llnl.gov. Address comments
about our rulemaking Web site to Carol Gallagher, (301) 415-5905; (e-
mail cag@nrc.gov). Comments can also be submitted via the Federal
eRulemaking Portal http:www.regulations.gov.
Hand deliver comments to: 11555 Rockville Pike, Rockville,
Maryland, between 7:30 a.m. and 4:15 p.m. on Federal workdays.
Publicly available documents related to this petition may be viewed
electronically on the public computers located at the NRC Public
Document Room (PDR), O1 F21, One White Flint North, 11555 Rockville
Pike, Rockville, Maryland. The PDR reproduction contractor will copy
documents for a fee. Selected documents, including comments, may be
viewed and downloaded electronically via the NRC rulemaking Web site at
https://ruleforum.llnl.gov.
Publically available documents created or received at the NRC after
November 1, 1999 are also available electronically at the NRC's
Electronic Reading Room at https://www.nrc.gov/reading-rm/adams.html.
From this site, the public can gain entry into the NRC's Agencywide
Documents Access and Management System (ADAMS), which provides text and
image files of NRC's public documents. If you do not have access to
ADAMS or if there are problems in accessing the documents located in
ADAMS, contact the NRC PDR Reference staff at 1-800-397-4209, 301-415-
4737 or by e-mail to pdr@nrc.gov.
For a copy of the petition, write to Michael T. Lesar, Chief,
Rulemaking, Directives and Editing Branch, Division of Administrative
Services, Office of Administration, U.S. Nuclear Regulatory Commission,
Washington, DC 20555-0001.
FOR FURTHER INFORMATION CONTACT: Michael T. Lesar, Office of
Administration, U.S. Nuclear Regulatory Commission, Washington, DC
20555. Telephone: 301-415-7163 or Toll-Free: 1-800-368-5642 or E-mail:
MTL@NRC.Gov.
SUPPLEMENTARY INFORMATION:
Background
The NRC has received a petition for rulemaking dated March 15,
2007, submitted by Mark Edward Leyse (petitioner). The petitioner
requests that the NRC amend 10 CFR part 50, ``Domestic Licensing of
Production and Utilization Facilities.'' Specifically, the petitioner
requests that all holders of operating licenses for nuclear power
plants be required to operate such plants at operating conditions
(e.g., levels of power production, fuel cycle lengths, and light-water
coolant chemistries) necessary to effectively limit the thickness of
crud (corrosion products) layers and/or oxide layers on fuel rod
cladding surfaces. The petitioner believes that new regulations are
needed for reactor-operation parameters, uranium-oxide and mixed-oxide
fuel and cladding, in order to ensure that cladding is free of unsafe
thicknesses of crud and/or oxide, which in turn would help ensure that
nuclear power plants operate in compliance with 10 CFR 50.46(b). 10 CFR
50.46(b) stipulates that the calculated peak cladding temperature (PCT)
must not exceed 2200[deg]F in the event of a loss-of-coolant accident
(LOCA). The petitioner also requests that 10 CFR part 50, Appendix K,
``ECCS Evaluation Models'' be amended to require that the steady-state
temperature distribution and stored energy in the fuel at the onset of
a postulated LOCA be calculated by factoring in the role that the
thermal resistance of crud and/or oxide layers on cladding plays in
increasing the stored energy in the fuel. Lastly, the petitioner
requests that Sec. 50.46 be amended to stipulate a maximum allowable
percentage of hydrogen content in fuel cladding.
The NRC has determined that the petition meets the threshold
sufficiency requirements for a petition for rulemaking under 10 CFR
2.802. The petition has been docketed as PRM-50-84. The NRC is
soliciting public comment on the petition for rulemaking.
Discussion of the Petition
The petitioner states that layers of crud and oxide on cladding
surfaces of nuclear fuel rods could cause the temperature of fuel rods
to increase up to 300 [deg]F to 600 [deg]F during power plant
operations. The petitioner also states that during a LOCA, the thermal
resistance of insulating layers of crud and oxide on cladding, and
increased fuel temperatures will cause the PCT to be higher than if the
cladding were clean. The petitioner believes that if a large break (LB)
LOCA occurred at a nuclear power plant that operated with heavy crud
and oxide layers, there is a high probability that the PCT would exceed
the 2200 [deg]F limit in Sec. 50.46(b)(1). The petitioner states that
increased hydrogen content in cladding contributes to cladding
embrittlement. The petitioner believes that Sec. 50.46 should also be
amended to specify a maximum allowable percentage of hydrogen in
cladding.
The petitioner states that in 2001, the Indian Point Unit 2
facility had a PCT of 2188 [deg]F during a computer simulated LB LOCA.
The petitioner believes that if heavy crud and oxide layers were
present and included in the calculation, it is ``highly probable'' the
calculated PCT would have exceeded the 2200 [deg]F limit, perhaps by
hundreds of degrees Fahrenheit. The petitioner states that if the 2200
[deg]F limit was exceeded during actual operation, the cladding could
lose its physical integrity and result in a core meltdown that would
release radioactive material and contaminate the environment. The
petitioner states that in 1995, the Three Mile Island Unit 1 facility
(TMI-1) operated with crud deposits on the surface of fuel rods that
raised the cladding temperature by 180 to 270 [deg]F or greater over
the typical operating temperature of 346 [deg]C during Cycle 10. The
petitioner believes that if an actual LB LOCA had occurred at TMI-1,
the crud and oxide layers on the cladding would have caused the PCT to
exceed 2200 [deg]F.
The petitioner states that because corrosion is not detected during
plant operation, a significant length of time passes before corrosion
progresses enough to perforate cladding and cause an increase in
``offgas'' activity meaning that heavily corroded fuel rods are often
operated at full power for significant periods of time and could cause
the cladding to fracture during the reflood period and lose structural
integrity. The petitioner concludes that this could compromise the
structural soundness
[[Page 28904]]
and the ability to keep the core cooled and illustrates the impact that
the thermal resistance of heavy layers of oxide and crud on cladding
would have during a LOCA.
The petitioner cites a September 30, 2003, Advisory Committee on
Reactor Safeguards (ACRS) meeting transcript stating that the thickness
of crud deposited on the cladding during pressurized water reactor
(PWR) plant operation is often not known because ``a great deal of PWR
crud comes off the cladding during reactor shutdown.'' The petitioner
notes that crud deposits on cladding in PWRs have been measured at up
to 125[mu]m thick. The ACRS found that a crud layer with steam
blanketing would have ``extremely poor conductivity'' and that crud is
``difficult to characterize'' because its thermal conductivities
``depend on [its] morpholog[ies].''
The petitioner also cites an Electric Power Research Institute
(EPRI) study to be completed in 2008 that will attempt ``to determine
the effect of tenacious crud on fuel surface heat transfer.'' The
petitioner notes that this study is for crud in a boiling water reactor
(BWR) but believes the results can also be applied to PWRs.
The petitioner also notes that the EPRI study found that Zirconium
dioxide (ZrO2) has a low thermal conductivity and is used
industrially as an insulating material. The petitioner cites an EPRI-
sponsored study entitled, ``Taming the Crud Problem: The Evolution,''
presented at the Advances in Nuclear Fuel Management II Conference in
October 2003 which states that: ``Oxide can form, with or without the
benefit of crud, in the presence of sustained cladding temperatures.
Like crud, formation of an oxide layer inhibits heat transfer causing
accelerated corrosion which can potentially lead to fuel failure.''
The petitioner describes a fuel rod that failed at TMI-1 during
Cycle 10 that may have had about a 200[mu]m-thick layer of crud and
oxide. The petitioner believes that if a LB LOCA occurred during this
fuel cycle, the layer of crud and oxide would have inhibited effective
heat transfer and likely caused the PCT to exceed 2200 [deg]F, possibly
causing a meltdown. The petitioner also reiterates that in 2001, the
Indian Point Unit 2 facility had a PCT of 2188 [deg]F in a computer
simulated LB LOCA. The petitioner believes that if Indian Point Unit 2
had cladding conditions similar to those of TMI-1 Cycle 10, it is
highly probable the PCT would also have been greater than 2200 [deg]F.
The petitioner states that TMI-1 is not the only PWR to experience
crud-induced corrosion failures. In 1997, the Palo Verde Unit 2 and
Seabrook facilities both had the same problem.
The petitioner cites NUREG-1230, ``Compendium of ECCS Research for
Realistic LOCA Analysis'' and states that the stored energy in the fuel
increases because cladding encased in heavy amounts of crud and oxide
cannot transfer heat efficiently to coolant during the blowdown phase
of the event. The petitioner states that the increased stored energy
caused by heavy crud and oxide layers on fuel cladding and the delay in
the transfer of the heat to the coolant cause the cladding to be
subjected to extremely high temperatures for much longer than if the
cladding was clean (free of crud and oxidation) at the onset of the
LOCA. The petitioner believes that this would result in more
degradation of the fuel and embrittlement of cladding. The petitioner
also states that when the cladding reacts with steam, an exothermic
reaction occurs that generates additional heat on the cladding.
The petitioner cites an ACRS meeting transcript from February 2,
2007, in which an NRC staff member explained that a basic LOCA
transient calculation includes an oxidation limit and involves time and
temperature. The petitioner also notes that NUREG-1230 states that
embrittled cladding can fragment upon contact with emergency cooling
water in a severe accident. The embrittlement is a function of
temperature, time, the supply of steam and zircaloy, and can lead to
the loss of effective cooling, making it relevant to fuel rod safety.
The petitioner also notes that NUREG-1230 also states, ``[the] amount
of residual thermal energy [in the fuel rod] influences the time
required to quench the reactor core with emergency cooling water
[emphasis added].''
The petitioner states that absorption of hydrogen would also
contribute to a loss of cladding ductility during a LOCA along with
cladding degradation and massive oxidation. He cites a failed fuel rod
from the TMI-1, Cycle 10 event when hydrogen absorption caused hydrided
material to break away from the outer portions of the cladding. The
petitioner believes that the effects of increased stored energy due to
a heavy crud layer in the fuel and the severity of cladding oxidation,
embrittlement, and resulting fuel degradation during an actual event
would be substantially greater than in an ECCS calculation based on
clean cladding.
The petitioner also states that little or no evidence exists that
crud has ever been properly factored into PCT calculations for
postulated LOCAs. He cites a June 17, 2003, Idaho National Engineering
and Environmental Laboratory document that he believes stated that crud
has not been applied to severe accident codes because it has not been
demonstrated to be necessary and that users have not chosen to consider
effects of crud. The petitioner also cites the 2002 annual report on
ECCS evaluation from the Callaway facility that he believes proves that
``little attention'' was placed on effects of heavy crud on thermal
resistance. The petitioner states that most cladding that experienced
crud-induced corrosion failures recently at PWRs involved high-power,
one-cycle fuel. He cites the TMI-1, Cycle 10 and Callaway, Cycle 6
events as examples and notes that the effects of crud can occur
quickly. The cladding perforation at TMI-1 was detected only 121 days
into the cycle.
The petitioner states that the values of the stored energy in BOL
fuel or fuel with burnups between 30 to 35 GWd/MTU are used to
calculate PCTs during postulated LOCAs. The petitioner also believes it
is significant that the stored energy of fuel sheathed in cladding with
heavy crud and oxide layers is substantially higher than fuel of the
same burnup rate sheathed in clean cladding that he states is used in
PCT calculations performed for postulated LOCAs and during safety
evaluations of the certification process of newer designs such as the
Westinghouse AP 1000 reactor. The petitioner believes that the AP 1000
PCTs were not calculated for the maximum stored energy that fuel can
reach during operation and that recent experiences with fuel at TMI-1,
Palo Verde Unit 2, and Seabrook were not considered in PCT calculations
performed during recent power ``uprates'' at other nuclear power
facilities.
The petitioner states that axial offset anomaly (AOA) or crud-
induced power shift (CIPS) are phenomena caused by crud on cladding and
can indicate how frequently crud affects nuclear power plant operation.
The petitioner also states that AOA occurs in PWRs when crud deposits
on cladding contain enough boron to reduce the rate of fission in the
vicinity of the crud. He cites NRC Information Notice 97-85, ``Effects
of Crud Buildup and Boron Deposition on Power Distribution and Shutdown
Margin'' that describes how AOA causes power distribution shifts toward
the bottom of the reactor core as a result of reduced fission in the
upper reactor core. The petitioner states that although crud deposits
must be at least 35[mu]m thick for AOA to occur, it is possible that
crud deposits thicker than 35[mu]m do not cause AOA because not all
[[Page 28905]]
crud deposits contain enough boron to cause this phenomenon. The
petitioner also states that according to a 2002 Department of Energy
report on nuclear energy plant optimization, the thickest layer of crud
measured in a PWR was 125[mu]m thick that caused AOA but not cladding
perforation and that as of 2003, more than 30 fuel cycles in 16 PWRs
had exhibited AOA.
The petitioner also cites a 2006 EPRI report that acknowledged that
crud has contributed to AOA at many power plants since the 1980s
because fuel cycle operation and power up rates have increased
appreciably and that excessive crud deposits create operational
difficulties. According to a Westinghouse Electric Company official,
AOAs are detectable and closely monitored to ensure that adequate
shutdown margins can be maintained. Also, a plant can be operated at a
lower power level if necessary. The petitioner cites the TMI-1, Cycle
10 event as an example that illustrates how low levels of boron can
result in a slight AOA even though enough crud was present to induce
fuel failure from corrosion. The petitioner states that if a heavy crud
layer was detected during plant operation that did not cause an AOA, it
is unlikely that the operation power level would be reduced because the
thermal resistance of the crud and how it would raise the PCT during a
LOCA would likely not be considered problematic.
The petitioner describes what he believes was a crud-induced
cladding corrosion failure of fuel in a BWR at the River Bend facility
during Cycle 8 from 1998-99. The petitioner states that the fuel
failure occurred when crud nearly bridged the gap between adjacent rods
and believes it is significant that most of the failed rods were high-
power, one-cycle rods (much like the recent corrosion-induced PWR fuel
failures during the TMI-1 Cycle 10, Palo Verde Unit 2 Cycle 9, and
Seabrook Cycle 5 events). The River Bend Cycle 8 fuel failure resulted
from thick layers of crud, augmented with copper that accelerated the
oxidation process to produce a local steam blanketing and high heat
transfer resistance that created perforations in the fuel cladding
according to the ``Recent GE BWR Fuel Experience'' report published in
2000 by the American Nuclear Society and the NRC inspection report
pertaining to this event. The petitioner concludes that the combined
effects of crud and oxide layers increased the cladding temperatures
from around 560 [deg]F to temperatures approaching 1200 [deg]F.
The petitioner states that if a LOCA had occurred during this
event, the PCT could likely have exceeded the 2200 [deg]F limit
specified in Sec. 50.46. The petitioner acknowledges that the NRC
Licensee Event Report (LER) 50-458/99-016-00 states that the PCT was
calculated to have been 1700 [deg]F or less and demonstrates a
substantial margin to the 2200 [deg]F limit. However, the petitioner
states that the LER ignores NRC guidelines for calculating the
equivalent cladding reacted (ECR) and believes that the PCT would have
exceeded 1700 [deg]F during a LB LOCA. The petitioner states that in
2000 when this LER was filed there was not much knowledge about values
for the thermal conductivity of crud and how crud layers should be
modeled in severe accident codes and believes this lack of knowledge
still exists in 2007. The petitioner reiterates there is little or no
evidence that crud has ever been properly factored into PCT
calculations for simulated LOCAs at nuclear power plants.
The petitioner states that essentially the same cladding condition
occurred again at the River Bend facility between October 2001 to March
2003 during the Cycle 11 refueling event after a GE Nuclear Energy
official had stated that heavy crud buildup during the Cycle 8 event
was unique and had occurred only once in over 1000 reactor years of
operation. He cites a paper presented at the 2004 International Meeting
on LWR Fuel presented by the American Nuclear Society, ``Fuel Failures
During Cycle 11 at River Bend.'' This paper stated that this fuel rod
failure was caused by accelerated oxidation of the cladding resulting
from unusually heavy deposits of tenacious crud that diminished heat
transfer in local areas of the cladding surface. The petitioner notes
that the failures occurred in high power, one-cycle rods where heavy
crud and oxide layers were present. The petitioner believes that the
PCT during a LB LOCA would have exceeded the 2200 [deg]F limit
specified in Sec. 50.46 and means that the ECCS design basis for River
Bend is non-conservative for calculating the PCT for a postulated LOCA
when heavy crud and oxide layers exist on cladding.
The petitioner disputes GE Nuclear Energy's conclusion that because
the heavy crud deposits on fuel rods at the River Bend facility
occurred at the lower elevations of the fuel assembly and the more
limiting axial elevations during a postulated LOCA occur at the upper
elevations of a fuel assembly where at River Bend the crud
characteristics were normal, the heavy crud deposits would have no
significant effect on the fuel response to a postulated LOCA. The
petitioner states that the cladding surface temperatures during the
River Bend events reached 1200 [deg]F, far above the specified
licensing basis of about 578 [deg]F. The petitioner believes that the
higher temperatures due to the heavy crud and oxide layers would result
in less coolant flow than for clean cladding, would cause the cladding
to be subjected to extremely high temperatures for a substantially
longer duration than used in the licensing basis, and result in more
fuel degradation. The petitioner also believes that the degradation of
fuel and cladding would further obstruct reflood coolant flow, delay
transfer of stored energy to the coolant during quench, and that during
a LOCA there would already be severe cladding degradation, massive
oxidation, and absorption of hydrogen that would contribute to a loss
of cladding ductility. The petitioner has concluded that these factors
mean that the River Bend facility operated in violation of Sec.
50.46(b) during cycles 8 and 11 of refueling. The petitioner also
states that the Browns Ferry facility operated from April 2001 to March
2003 with thick oxide layers at the upper elevations of the fuel rods
and believes it is significant that the heavy crud and oxide layers
that caused overheating and cladding perforations at TMI-1 during cycle
10 were located at upper elevations of fuel assemblies.
The petitioner cites a 2004 paper, ``An Integrated Approach to
Maximizing Fuel Reliability'' stating that a lack of understanding
exists about the interplay of materials, fuel duty, and water chemistry
variables and reports that crud or corrosion related fuel failures
occurred at BWRs in six of the years between 1997 to 2004. The
petitioner also cites an EPRI document, ``2006 Portfolio 41.002 Fuel
Reliability'' which states that the fuel failure rate has increased in
both BWRs and PWRs during the last couple of years due to extended and
more aggressive fuel cycle operation. The petitioner states that
although the nuclear industry observed that it appeared that nodular
corrosion had been eliminated from BWR fuel cladding in 2000, by 2004
it had reemerged at several BWRs. The petitioner believes this is a
result of increasing fuel duty by extending the length of fuel cycles
and that problems with crud and oxide will continue unless the NRC
implements regulations to ensure that BWRs and PWRs do not operate with
high levels of crud and oxidation on cladding that cause violations of
Sec. 50.46(b).
The petitioner states that Appendix K to 10 CFR part 50, ``ECCS
Evaluation Models'' requires stored energy in nuclear fuel to be
calculated to yield the highest PCT. The petitioner believes that
Appendix K should require thermal
[[Page 28906]]
conductivity of layers of crud and oxide to be factored into
calculations of the stored energy in the fuel. The petitioner states
that because a heavy crud layer would increase the quantity of stored
energy in the fuel, the PCT would also increase above that of fuel with
the same burnup sheathed in clean cladding. The petitioner also states
that instructions specified in Appendix K for calculating the quantity
of stored energy that contains heavy layers of crud and oxide are non-
conservative.
The petitioner notes that values of stored energy in BOL fuel or
fuel with burnups between 30 to 35 Gwd/MTU are used to calculate PCTs
during postulated LOCAs. However, the petitioner cites a January 2007
ACRS Subcommittee on Materials, Metallurgy, and Reactor Fuels during
which a Westinghouse official cited data from LOCA calculations showing
that single cycle fuel with burnups from zero to approximately 20 or 25
GWd/MTU yielded the highest PCTs. Westinghouse also stated that at
burnups of about 30 GWd/MTU, there is approximately a ten percent
reduction in achievable power, which yields PCTs approximately 100
[deg]C lower than those of fresh fuel. The petitioner concludes it is
significant that an ECCS design based on Appendix K requirements is
non-conservative and hazardous for calculating the quantity of stored
energy in one-cycle fuel that has heavy crud on the cladding.
The petitioner states that an increase in hydrogen content in
cladding contributes to cladding embrittlement. The petitioner cites an
April 4, 2001, ACRS Reactor Fuels Subcommittee meeting during which an
expert from Argonne National Laboratory stated that a reduction of
ductility occurs when hydrogen levels reach about 600 to 700 parts-per-
million (ppm) in Zircaloy cladding. According to the petitioner,
another expert from the Atomic Energy Research Institute stated that a
threshold for a reduction of ductility in Zircaloy cladding occurs at
even a lower hydrogen level of about 150 to 200 ppm. The petitioner
also cites the TMI-1 Cycle 10 event that included massive hydrogen
absorption in fuel cladding. The petitioner notes that hydrogen content
in the cladding of a rod that did not fail measured 700 ppm at TMI-1
and that this level of hydrogen content in one-cycle cladding is
similar to the 800 ppm level measured in fuel cladding at the H.B.
Robinson, Unit 2 facility, a PWR. The petitioner states that some of
the cladding at TMI-1 Cycle 10 contained levels of hydrogen that
Argonne National Laboratory found would have caused a loss of cladding
ductility in addition to the embrittlement resulting from excessive
oxide levels.
The Petitioner's Proposed Actions
The petitioner states that new regulations are needed for reactor
operation parameters, uranium-oxide and mixed-oxide fuel, and fuel
cladding to ensure that cladding does not contain unsafe amounts of
crud and oxide to help ensure that nuclear power plants operate in
compliance with 10 CFR 50.46(b). The petitioner also states that
nuclear power plant licensees should be required to factor the thermal
resistance effects of crud and oxide layers on cladding into
calculations of PCTs for postulated LOCAs at their facilities. Also,
the NRC needs to consider effects of crud and oxide when reviewing
power plant operations reports under 10 CFR 50.46, and before approving
power uprates at existing facilities and new nuclear power plant
designs, such as the recently certified Westinghouse AP1000 design.
The petitioner requests that Appendix K to Part 50 be amended to
require that the steady state temperature distribution and stored
energy in the fuel at the onset of a postulated LOCA be calculated by
factoring in the role that the thermal resistance of crud and oxide
layers on cladding plays in increasing the stored energy in nuclear
fuel. The petitioner also states that Appendix K should specify
instructions to more accurately calculate the role that thermal
resistance of crud and oxide layers on cladding plays in determining
the stored energy in the fuel and the PCT during a postulated LOCA.
Lastly, the petitioner requests that Sec. 50.46 be amended to
include a requirement that stipulates a maximum allowable percentage of
hydrogen content in cladding because there is extensive evidence that
excessive hydrogen levels and oxidation on cladding contributes to
cladding embrittlement. The petitioner concludes that the requested
amendments should also apply to any NRC-approved, best-estimate ECCS
evaluations used instead of Appendix K calculations. The petitioner
believes its requested amendments would ensure that nuclear power
facilities prevent unsafe amounts of crud and oxide layers on cladding
from occurring during operation to reduce risks to plant workers and
the public, and help nuclear power facility operations to comply with
10 CFR 50.46(b).
Dated at Rockville, Maryland, this 15th day of May 2007.
For the Nuclear Regulatory Commission.
Annette L. Vietti-Cook,
Secretary of the Commission.
[FR Doc. E7-9910 Filed 5-22-07; 8:45 am]
BILLING CODE 7590-01-P