Notice of Availability of Model Safety Evaluation and Model License Amendment Request on Technical Specification Improvement Regarding Use of the Improved Banked Position Withdrawal Sequence for General Electric Boiling Water Reactors Using the Consolidated Line Item Improvement Process, 29004-29010 [07-2563]
Download as PDF
29004
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Notices
Specifically, the law requires that the
Federal government create and maintain
a single searchable Web site, accessible
by the public at no cost to access, that
includes specific data elements about
most federal awards. Understanding this
new legislation is extremely important
to all GPC stakeholders because
ultimately this law will apply to most
awardees and sub-awardees, and federal
agencies will require awardees to
provide much of the needed data as a
condition of receiving federal financial
assistance.
Secondarily, the purpose of the
webcast meeting is to inform
stakeholders about the GPC’s long-term
planning and prioritization efforts and
to receive input from stakeholders to
inform a draft plan that will include
both GPC’s mission and vision, as well
as a listing of GPC priorities as they
relate to ongoing activities connected to
the FGSI.
Meeting structure and agenda: The
June 19 Webcast meeting will have the
following structure and agenda:
(1) Welcome by the host agency;
(2) Overview of the FFATA by the
Chair of the GPC;
(3) Overview of the GPC’s long-term
planning and proposed priorities by the
Chair of the GPC; and
(4) Participants’ discussion, questions
and comments.
Background: Background about the
FGSI is set forth in the Federal Register
published on September 13, 2006 (71 FR
54098).
I. Introduction
The Nuclear Regulatory Commission
(NRC) is hosting a workshop to discuss
issues of interest pertaining to the
regulation of NRC-regulated fuel cycle
facilities. The purpose of the workshop
is to discuss various issues of the
regulatory program related to the update
of 10 CFR part 70. The specific issues
to be discussed are 10 CFR part 70,
Appendix A reportability of incidents,
digital control systems, enforcement
policy revisions, uranium solubility
issues.
The workshop will be held in
Rockville, Maryland, at the NRC’s
Executive Boulevard Building, located
at 6003 Executive Boulevard and will be
open to the public. We are expecting
that NRC staff, licensees and certificate
holders, and other interested parties and
stakeholders will be making
presentations on these issues of interest,
with opportunity for followup
discussion on each subject.
II. Dates and Location
Date: June 14, 2007. 9 a.m.–5:30 p.m.
U.S. Nuclear Regulatory Commission,
Executive Boulevard Building, 6003
Executive Boulevard, Rockville, MD
20852.
III. Contact
Dated: May 17, 2007.
Thomas Cooley,
Chair, Grants Policy Committee of the U.S.
Chief Financial Officer Council.
[FR Doc. E7–9839 Filed 5–22–07; 8:45 am]
James Smith, Project Manager, Office
of Nuclear Material Safety and
Safeguards, Division of Fuel Cycle
Safety and Safeguards, Special Projects
Branch, Mail Stop: T8F42, 301–415–
6459, Fax: 301–415–5370, e-mail:
jas4@nrc.gov.
BILLING CODE 7555–01–P
IV. Further Information
NUCLEAR REGULATORY
COMMISSION
Notice of Public Meeting for Fuel Cycle
Facilities
Nuclear Regulatory
Commission.
ACTION: Public Meeting Notice.
AGENCY:
pwalker on PROD1PC71 with NOTICES
FOR FURTHER INFORMATION CONTACT:
James Smith, Project Manager,
Technical Support Section, Division of
Fuel Cycle Safety and Safeguards, Office
of Nuclear Material Safety and
Safeguards, U.S. Nuclear Regulatory
Commission, Washington, DC 20005–
0001. Telephone: (301) 415–6459; fax
number: (301) 415–5370; e-mail:
jas4@nrc.gov.
The document related to this action is
available electronically at the NRC’s
Electronic Reading Room at https://
www.nrc.gov/reading-rm/adams.html.
From this site, you can access the NRC’s
Agencywide Documents Access and
Management System (ADAMS), which
provides text and image files of NRC’s
public documents. The ADAMS
accession number for the document
related to this notice is provided in the
following table. If you do not have
access to ADAMS or if there are
problems in accessing the document
located in ADAMS, contact the NRC
Public Document Room (PDR) Reference
staff at 1–800–397–4209, 301–415–4737,
or by e-mail to pdr@nrc.gov.
Dated at Rockville, Maryland, this 16th day
of May 2007.
SUPPLEMENTARY INFORMATION:
VerDate Aug<31>2005
18:32 May 22, 2007
Jkt 211001
PO 00000
Frm 00060
Fmt 4703
Sfmt 4703
For the Nuclear Regulatory Commission.
Margie Kotzolas,
Acting Chief, Technical Support Branch,
Special Projects and Technical Support
Directorate, Division of Fuel Cycle Safety and
Safeguards, Office of Nuclear Materials Safety
and Safeguards.
[FR Doc. E7–9923 Filed 5–22–07; 8:45 am]
BILLING CODE 7590–01–P
NUCLEAR REGULATORY
COMMISSION
Notice of Availability of Model Safety
Evaluation and Model License
Amendment Request on Technical
Specification Improvement Regarding
Use of the Improved Banked Position
Withdrawal Sequence for General
Electric Boiling Water Reactors Using
the Consolidated Line Item
Improvement Process
Nuclear Regulatory
Commission.
ACTION: Request for comment.
AGENCY:
SUMMARY: Notice is hereby given that
the staff of the U. S. Nuclear Regulatory
Commission (NRC) has prepared a
model license amendment request
(LAR), model safety evaluation (SE), and
model proposed no significant hazards
consideration (NSHC) determination
related to changes to Standard
Technical Specification (STS) 3.1.6,
‘‘Rod Pattern Control,’’ and STS 3.3.2.1,
‘‘Control Rod Block Instrumentation’’
for NUREG–1433 and NUREG–1434.
The proposed changes would revise the
Technical Specifications (TS) and Bases
for STS 3.1.6, ‘‘Rod Pattern Control,’’
and STS 3.3.2.1, ‘‘Control Rod Block
Instrumentation’’ to allow licensees to
use an improved control rod banked
position withdrawal sequence (BPWS)
when performing a reactor shutdown. In
addition, the proposed changes would
add a footnote to Table 3.3.2.1–1,
‘‘Control Rod Block Instrumentation’’
for NUREG–1433 and NUREG–1434.
The requirements for implementing the
improved BPWS are described in
General Electric Licensing Topical
Report (LTR) NEDO–33091–A, Revision
2, ‘‘Improved BPWS Control Rod
Insertion Process,’’ dated July 2004. The
General Electric Boiling Water Reactor
Owner’s Group (BWROG) participants
in the Technical Specifications Task
Force (TSTF) initially proposed these
changes to the STS in TSTF–476,
Revision 0, ‘‘Improved BPWS Control
Rod Insertion Process (NEDO–33091).’’
TSTF–476, Revision 1 was submitted on
January 9, 2007 and was later accepted
by NRC. Hereafter, all references to
TSTF–476 refer to TSTF–476, Revision
1, unless otherwise noted. Technical
E:\FR\FM\23MYN1.SGM
23MYN1
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Notices
pwalker on PROD1PC71 with NOTICES
Specifications and Bases changes
provided in TSTF–476 completely
supersede the proposed Technical
Specification changes included in
NEDO–3309 1–A.
The purpose of these models is to
permit the NRC to efficiently process
amendments to incorporate these
changes into plant-specific (TS) for
General Electric Boiling Water Reactors
(BWRs). Licensees of nuclear power
reactors to which the models apply can
request amendments conforming to the
models. In such a request, a licensee
should confirm the applicability of the
model LAR, model SE and NSHC
determination to its plant.
DATES: The NRC staff issued a Federal
Register Notice (71 FR 26118, May 3,
2006) which provided for public
comment a model SE, model LAR, and
NSHC determination related to changes
to STS 3.1.6, ‘‘Rod Pattern Control,’’ and
STS 3.3.2.1, ‘‘Control Rod Block
Instrumentation’’ for NUREG–1433 and
NUREG–1434. Similarly, the NRC staff
herein provides a revised model SE,
revised model LAR, and NSHC
determination. The NRC staff can most
efficiently consider applications based
upon the model LAR, which references
the Model SE, if the application is
submitted within one year of this
Federal Register Notice.
FOR FURTHER INFORMATION CONTACT:
Timothy Kobetz, Mail Stop: O–12H2,
Division Inspection and Regional
Support, Office of Nuclear Reactor
Regulation, U.S. Nuclear Regulatory
Commission, Washington, DC 20555–
0001, telephone 301–415–1932.
SUPPLEMENTARY INFORMATION:
Background
Regulatory Issue Summary 2000–06,
‘‘Consolidated Line Item Improvement
Process (CLIIP) for Adopting Standard
Technical Specifications Changes for
Power Reactors,’’ was issued on March
20, 2000. The CLIIP is intended to
improve the efficiency and transparency
of NRC licensing processes. This is
accomplished by processing proposed
changes to the STS in a manner that
supports subsequent license amendment
applications. The CLIIP includes an
opportunity for the public to comment
on proposed changes to the STS
following a preliminary assessment by
the NRC staff and finding that the
change will likely be offered for
adoption by licensees.
The CLIIP directs the NRC staff to
evaluate any comments received for a
proposed change to the STS and to
either reconsider the change or proceed
with announcing the availability of the
change for proposed adoption by
VerDate Aug<31>2005
18:32 May 22, 2007
Jkt 211001
licensees. In several instances, the staff’s
evaluation did result in changes to the
model LAR. Those licensees opting to
apply for the subject change to TS are
responsible for reviewing the staff’s
evaluation, referencing the applicable
technical justifications, and providing
any necessary plant-specific
information. The model LAR shows
licensees the expected level of detail
that needs to be included in order to
adopt TSTF–476, as well as guidelines
for staff review. The NRC has
established an internal review plan that
designates the appropriate staff and
approximate time lines to review plantspecific LARs that reference TSTF–476.
Each amendment application made in
response to the notice of availability
will be processed and noticed in
accordance with applicable NRC rules
and procedures.
This notice involves implementation
of an improved BPWS, which allows
licensees of General Electric BWRs to
follow the improved BPWS when
inserting control rods into the core
during a reactor shutdown. By letter
dated January 9, 2007, the BWROG
proposed these changes for
incorporation into the STS as TSTF–
476. These changes are based on the
NRC staff-approved LTR NEDO–33091–
A, ‘‘Improved BPWS Control Rod
Insertion Process,’’ dated July 2004, as
approved by NRC in a SE dated June 16,
2004, accessible electronically from the
Agency-wide Documents Access and
Management System’s (ADAMS) Public
Electronic Reading Room on the Internet
(ADAMS Accession No. ML041700479)
at the NRC Web site https://www.nrc.gov/
reading-rm/adams.html. Persons who
do not have access to ADAMS or who
encounter problems in accessing the
documents located in ADAMS, should
contact the NRC Public Document Room
Reference staff by telephone at 1–800–
397–4209, 301–415–4737, or by e-mail
to pdr@nrc.gov.
Applicability
These changes revise the Section 3.1.6
and Section 3.3.2.1 TS and Bases for
NUREG–1433 and NUREG–1434
(General Electric BWR/4 and BWR/6
plants, respectively), and TS Table
3.3.2.1–1 for NUREG–1433 and
NUREG–1434.
To efficiently process the incoming
license amendment applications, the
NRC staff requests each licensee
applying for the changes addressed by
TSTF–476 use the CLIIP to submit a
LAR that adheres to the following
model. Any deviations from the model
LAR should be explained in the
licensee’s submittal. The CLIIP does not
prevent licensees from requesting an
PO 00000
Frm 00061
Fmt 4703
Sfmt 4703
29005
alternative approach, proposing the
changes without providing the
information described in the eight
model LAR conditions, or making the
requested commitment. Variations from
the approach recommended in this
notice may, however, require additional
review by the NRC staff and may
increase the time and resources needed
for the review. Significant variations
from the approach, or inclusion of
additional changes to the license, may
result in staff rejection of the submittal.
Instead, licensees desiring significant
variations and/or additional changes
should either submit a LAR that does
not claim to adopt TSTF–476, or
specifically state in their LAR that they
are adopting TSTF–476 without using
the CLIIP.
Public Notices
In a notice in the Federal Register
dated May 3, 2006 (71 FR 26118), the
staff requested comment on the use of
the CLIIP to process requests to revise
Section 3.1.6 and Section 3.3.2.1 TS and
Bases and TS Table 3.3.2.1–1 for
NUREG–1433 and NUREG–1434, as
discussed in TSTF–476. In response to
this notice, the staff received one set of
comments (developed by the Technical
Specifications Task Force and submitted
in a letter dated May 31, 2006 (ADAMS
Accession No. ML061520129)). Specific
comments on the model LAR were
offered. These comments, along with the
NRC staff’s responses, are summarized
and discussed below:
1. Comment: In the Applicability
Section of the Notice and the model
application, the terms ‘‘BWR/4’’ and
‘‘BWR/6’’ are used incorrectly. These
terms should be revised to NUREG–
1433 and NUREG–1434, respectively.
The changes proposed are applicable to
BWR/2–6 plants, if they have adopted
the standard banked position
withdrawal sequence (BPWS). TSTF–
476 proposes changes to the Improved
Standard Technical Specifications
(ISTS) included in NUREG–1433 and
NUREG–1434, which may be applied to
any BWR type.
Response: The staff agrees with this
comment. References to BWR/4 and
BWR/6 have been replaced with
NUREG–1433 and NUREG–1434,
respectively.
2. Comment: The notice, the model
application, and the model Safety
Evaluation imply that a license
amendment is needed for plants with
Technical Specifications based on
NUREG–1433 to adopt TSTF–476. This
is not correct. No license amendment
request is required to adopt the
proposed Bases changes included in
TSTF–476 and no Technical
E:\FR\FM\23MYN1.SGM
23MYN1
pwalker on PROD1PC71 with NOTICES
29006
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Notices
Specification change is needed to adopt
TSTF–476 for plants with Technical
Specifications based on NUREG–1433.
Bases changes are made using the
licensee Technical Specification Bases
Control Program.
Response: The changes proposed by
TSTF–476, Revision 0, for NUREG–1433
(BWR/4) were only changes to the Bases
sections. However, a revised TSTF–476
was submitted to the NRC on January 9,
2007. The revised version of TSTF–476
includes changes to the Technical
Specifications and Bases sections for
both NUREG–1433 (BWR/4) and
NUREG–1434 (BWR/6). Therefore,
licensees proposing to adopt TSTF–476
are required to submit a license
amendment request.
3. Comment: In some BWR designs,
the rod worth minimizers (RWMs) (e.g.,
NUMAC) cannot be reprogrammed to
accept a new shutdown sequence. The
notice should state that bypassing the
RWM and entering the plant-specific
action equivalent to NUREG–1433
Specification 3.3.2.1, Required Action
D. 1, for an inoperable RWM during
shutdown (which requires the use of a
second qualified person to verify rod
movement in accordance with BPWS) is
acceptable and would not be considered
entering a Required Action for
‘‘operational convenience’’ as discussed
in the LCO 3.0.2 Bases.
Response: During the comment
disposition process it became apparent
that revisions to TSTF–476 would be
necessary. The changes proposed in
TSTF–476, Revision 0, included bases
changes to both NUREG–1433 (BWR/4)
and NUREG–1434 (BWR/6). In addition,
a note was proposed to be added to TS
Table 3.3.2.1–1 of NUREG–1434 to
allow the rod pattern controller to be
bypassed in Modes 1 and 2 so that the
BPWS can be used. A similar note was
not included in NUREG–1433 since
some BWR/4 plants rod worth
minimizer (RWM) can be reprogrammed
to accommodate the BPWS. However,
the RWM of some BWR/4 plants cannot
be reprogrammed to accommodate the
BPWS, and need a similar note to that
proposed for the BWR/6 NUREG–1434.
Therefore, to be acceptable, a
[bracketed] note similar to that proposed
to be added to TS Table 3.3.2.1–1 of the
BWR/6 NUREG–1434, was incorporated
into TSTF–476, revision 1. A revised
TSTF–476 was submitted to the NRC on
January 9, 2007. The changes
incorporated in the revised version of
TSTF–476 include changes to the
Technical Specifications and Bases
sections that require the adopting
licensee to submit a license amendment
request.
VerDate Aug<31>2005
18:32 May 22, 2007
Jkt 211001
4. Comment: The notice should state
that the Technical Specifications and
Bases changes provided in TSTF–476
completely supersede the proposed
Technical Specification changes
included in NEDO–3309 1–A.
Response: An appropriate statement
has been added in this notice.
5. Comment: Throughout the notice,
the acronym BPWS is defined
incorrectly. The term BPWS stands for
‘‘Banked Position Withdrawal
Sequence,’’ not ‘‘Bank Position
Withdrawal Sequence.’’
Response: Appropriate corrections
have been made throughout the notice
and its attachments.
6. Comment: Cover letter, 1st
paragraph—The license amendment
request will revise Table 3.3.2.1–1 only.
The associated Bases changes will be
made by the licensee upon
implementation using the Technical
Specifications Bases Control Program.
This also affects Sections I and 2 of
Enclosure I.
Response: The changes incorporated
in TSTF–476 include changes to the
Technical Specifications and Bases
sections that are needed by the adopting
licensee to submit a license amendment
request. While the Bases remain subject
to licensee control, a more timely
review will be possible if the licensee
requesting to adopt the changes
includes Technical Specification Bases
changes in its application.
7. Comment: Cover letter, 3rd
paragraph—Many licensees do not
provide final Technical Specifications
pages with the application. The final
pages are provided only after NRC
review has determined that no changes
from the draft are required. Revised
Bases pages are not required to be
provided with an application. The
Technical Specification Bases Control
Program requires revised Bases pages to
be provided to the NRC on a frequency
consistent with 10 CFR 50.71(e).
Response: While the Bases remain
subject to licensee control, for this
application the NRC staff plans to
review marked-up Technical
Specification and Technical
Specification Bases pages, as well as
pages that represent how the final
Technical Specification and Technical
Specification Bases pages will appear,
in order to review a licensee’s license
amendment application in the most
timely manner.
8. Comment: Enclosure 1, Section 2.0,
Proposed Changes, the first bullet
should reference the Bases for
Specification 3.1.6, not 3.6.1, if the
discussion of specific Bases changes is
retained in this section.
PO 00000
Frm 00062
Fmt 4703
Sfmt 4703
Response: Appropriate corrections of
the errors have been made to the model.
9. Comment: Enclosure 1, Section 2.0,
Proposed Changes, the second bullet
should discuss the rod pattern
controller, not the rod worth minimizer,
if the discussion of specific Bases
changes is retained in this section. In
addition, both bypassing and
reprogramming should be discussed.
Response: TSTF–476, revision 0
called for changes to Technical
Specification Section 3.3.2.1 Bases for
NUREG–1434. TSTF–476, revision 1
calls for changes to Technical
Specification Section 3.3.2.1 Bases for
both NUREG–1433 and NUREG–1434.
The specific equipment nomenclature
differs between the two standards. The
model has been updated using the
bracketing convention to allow the
selection of the appropriate equipment
nomenclature by the licensee prior to
amendment application.
10. Comment: Enclosure 1, Section
5.1, the last sentence should be deleted.
The NRC staff has already determined in
the Safety Evaluation for NEDO–33091
for all BWRs that no single failure of the
boiling water reactor mechanical or
hydraulic system can cause a control
rod to drop completely out of the reactor
core during the shutdown process. It is
unnecessary and a burden with no
safety benefit to require individual
licensees to verify the statement when it
has been generically approved by the
NRC for all BWRs.
Response: The staff’s approval and
safety evaluation are predicated upon
this determination, and the licensee’s
verification is deemed essential.
11. Comment: In Enclosure 1, Section
5.1 and in the model Safety Evaluation,
Section 3.0, commitment 1 should be
deleted. For those plants with Technical
Specifications based on NUREG–1434
which will be submitting a license
amendment request to adopt TSTF–476,
the proposed change to Table 3.3.2. 1–
1 requires confirming control rod
coupling integrity; therefore a separate
commitment to do the same is not
necessary.
Response: This is a commitment to
establish appropriate detailed
operational procedures prior to
implementation, and is deemed
essential.
12. Comment: Enclosure 1, Section 5.
1, and in the model Safety Evaluation,
Section 3.0 commitment 2 should be
deleted. This ‘‘commitment’’ is a
summary of the improved BPWS. The
model amendment, the model Safety
Evaluation, and the proposed Bases
reference the NRC approved Topical
Report as the basis for the improved
BPWS sequence. It is unclear what is
E:\FR\FM\23MYN1.SGM
23MYN1
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Notices
pwalker on PROD1PC71 with NOTICES
required by this commitment that is not
already required by adoption of the
Technical Specifications and Bases. It is
unnecessary to develop and track a
separate regulatory commitment to do
what is already required by the
amendment and Topical Report.
Response: This is a commitment to
establish appropriate detailed
operational procedures prior to
implementation, and is deemed
essential.
13. Comment: Description—
Amendment requests will only be
submitted by licensees with Technical
Specifications based on NUREG–1434.
Therefore, delete references to NUREG–
1433.
Response: BWR/4 plants with a RWM
that cannot be reprogrammed to
accommodate the BPWS will need to
amend their TS in order to adopt TSTF–
476. Therefore, references to NUREG–
1433 are not deleted.
14. Comment: Description and
Criterion I—The improved BPWS
insertion process applies during reactor
shutdowns. Delete the word ‘‘normal’’
before shutdown. The term ‘‘normal
shutdown’’ is not used in the model
Safety Evaluation or Topical Report.
The improved BPWS insertion process
applies to all shutdowns as long as the
conditions for use are met.
Response: The word ‘‘normal’’ has
been removed as a modifier for the term
‘‘shutdown’’ in applicable sections of
the model.
15. Comment: Criterion 2—Delete the
phrase ‘‘in the absence of other
unrelated failures’’ from the first
sentence. Criterion 2 only evaluates the
possibility of a new or different kind of
accident related to the proposed change,
not other unrelated events.
Response: The extraneous phrase has
been removed from the model SE.
For Inclusion on the Technical
Specification Web Page the following
example of an application was prepared
by the NRC staff to facilitate the
adoption of Technical Specifications
Task Force (TSTF) Traveler TSTF–476,
Revision 1 ‘‘Improved BPWS Control
Rod Insertion Process (NEDO–33091).’’
The model provides the expected level
of detail and content for an application
to adopt TSTF–476, Revision 1.
Licensees remain responsible for
ensuring that their actual application
fulfills their administrative
requirements as well as NRC
regulations.
U.S. Nuclear Regulatory Commission,
Document Control Desk, Washington, DC
20555.
Subject: Plant Name, Docket No. 50–[xxx,]
Re: Application for Technical Specification
Improvement To Adopt TSTF–476,
VerDate Aug<31>2005
18:32 May 22, 2007
Jkt 211001
Revision 1, ‘‘Improved BPWS Control Rod
Insertion Process (NEDO–33091)
Dear Sir or Madam: In accordance with the
provisions of Section 50.90 of Title 10 of the
Code of Federal Regulations (10 CFR),
[LICENSEE] is submitting a request for an
amendment to the technical specifications
(TS) for [PLANT NAME, UNIT NOS.].
The proposed changes would revise
Sections 3.1.6, ‘‘Rod Pattern Control,’’ and
3.3.2.1, ‘‘Control Rod Block
Instrumentation,’’ to allow [PLANT NAME]
to reference a new Banked Position
Withdrawal Sequence (BPWS) shutdown
sequence in the TS Bases. In addition, a
footnote is added to Table 3.3.2.1–1, ‘‘Control
Rod Block Instrumentation.’’
The changes are consistent with NRC
approved Industry Technical Specification
Task Force (TSTF) Standard Technical
Specification Change Traveler, TSTF–476,
Revision 1, Improved BPWS Control Rod
Insertion Process (NEDO–33091).’’ The
availability of this TS improvement was
announced in the Federal Register on
[DATE] ([ FR ]) as part of the consolidated
line item improvement process (CLIIP).
Enclosure 1 provides a description and
assessment of the proposed changes, as well
as confirmation of applicability. Enclosure 2
provides the existing TS pages and TS Bases
marked-up to show the proposed changes.
Enclosure 3 provides final TS pages and TS
Bases pages.
[LICENSEE] requests approval of the
proposed license amendment by [DATE],
with the amendment being implemented [BY
DATE OR WITHIN X DAYS]. In accordance
with 10 CFR 50.91, a copy of this application,
with enclosures, is being provided to the
designated [STATE] Official.
I declare under penalty of perjury under
the laws of the United States of America that
I am authorized by [LICENSEE] to make this
request and that the foregoing is true and
correct. [Note that request may be notarized
in lieu of using this oath or affirmation
statement]. If you should have any questions
regarding this submittal, please contact [ ].
Sincerely,
Name, Title
Enclosures:
1. Description and Assessment of Proposed
Changes
2. Proposed Technical Specification Changes
and Technical Specification Bases Changes
3. Final Technical Specification and Bases
pages.
cc: NRR Project Manager, Regional Office,
Resident Inspector, State Contact, ITSB
Branch Chief.
1.0 Description
This letter is a request to amend
Operating License(s) [LICENSE
NUMBER(S)] for [PLANT/UNIT
NAME(S)].
The proposed changes would revise
the Bases sections of Technical
Specification (TS) 3.1.6, ‘‘Rod Pattern
Control’’, and 3.3.2.1, ‘‘Control Rod
Block Instrumentation,’’ along with TS
Table 3.3.2.1–1, ‘‘Control Rod Block
Instrumentation,’’ to allow reference to
PO 00000
Frm 00063
Fmt 4703
Sfmt 4703
29007
an improved, optional Banked Position
Withdrawal Sequence (BPWS) for use
during reactor shutdown.
The new BPWS is described in
Topical Report NEDO–33091–A,
Revision 2, ‘‘Improved BPWS Control
Rod Insertion Process,’’ dated July 2004,
and approved by the NRC by Safety
Evaluation (SE) dated June 16, 2004
(ADAMS ML041700479). Technical
Specification Task Force (TSTF) change
traveler TSTF–476, Revision 1,
‘‘Improved BPWS Control Rod Insertion
Process (NEDO–33091)’’ was announced
for availability in the Federal Register
on [DATE] as part of the consolidated
line item improvement process (CLIIP).
2.0 Proposed Changes
Consistent with NRC-approved TSTF–
476, Revision 1, the proposed TS and
Bases changes include:
• Revised TS Section 3.1.6 Bases to
allow use of an optional BPWS during
plant shutdown.
• Revised TS Section 3.3.2.1 Bases to
allow reprogramming of the [rod worth
minimizer/rod pattern controller]
during the optional BPWS shutdown
sequence.
• Revised TS Table 3.3.2.1–1,
‘‘Control Rod Block Instrumentation,’’
which adds a footnote that allows
operators to bypass the [rod worth
minimizer/rod pattern controller] if
conditions for the optional BPWS
shutdown process are satisfied.
3.0 Background
The background for this application is
as stated in the model SE in NRC’s
Notice of Availability published on
[DATE ]([ ] FR [ ]), the NRC Notice for
Comment published on [DATE] ([ ] FR
[ ]), and TSTF–476, Revision 1.
4.0 Technical Analysis
[LICENSEE] has reviewed NEDO–
33091–A, Revision 2, and the staff’s SE
dated June 16, 2004, as well as TSTF–
476, Revision 1, and the model SE
published on [DATE] ([ ] FR [ ]) as part
of the CLIIP Notice for Comment.
[LICENSEE] has applied the
methodology in NEDO–33091–A,
Revision 2 to the develop the proposed
TS changes. [LICENSEE] has also
concluded that the justifications
presented in TSTF–476, Revision 1 and
the model SE prepared by the NRC staff
are applicable to [PLANT, UNIT NOS.],
and justify this amendment for the
incorporation of the changes to the
[PLANT] TS.
5.0 Regulatory Analysis
A description of this proposed change
and its relationship to applicable
regulatory requirements and guidance
E:\FR\FM\23MYN1.SGM
23MYN1
29008
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Notices
pwalker on PROD1PC71 with NOTICES
was provided in the NRC Notice of
Availability published on [DATE] ([ ] FR
[ ]), the NRC Notice for Comment
published on May 3, 2006 (71 FR
26118), and TSTF–476, Revision 1.
5.1 Regulatory Commitments
As discussed in the model SE
published in Federal Register on
[DATE] for this technical specification
improvement, the following plantspecific verifications/commitments
were performed. The safety evaluation
for NEDO–33091–A explained that the
potential for the control rod drop
accident (CRDA) will be eliminated by
the following changes to the operational
procedures, which [PLANT NAME] [has
made/will commit to make prior to
implementation]:
1. Before reducing power to the low
power setpoint (LPSP), operators shall
confirm control rod coupling integrity
for all rods that are fully withdrawn.
Control rods that have not been
confirmed coupled and are in
intermediate positions must be fully
inserted prior to power reduction to the
LPSP. No action is required for fullyinserted control rods.
If a shutdown is required and all rods,
which are not confirmed coupled,
cannot be fully inserted prior to the
power dropping below the LPSP, then
the original/standard BPWS must be
adhered to. The original/standard BPWS
can be found in Licensing Topical
Report (LTR) NEDO–21231, ‘‘Banked
Position Withdrawal Sequence,’’
January 1977, and is referred to in
NUREG–1433 and NUREG–1434.
2. After reactor power drops below
the LPSP, rods may be inserted from
notch position 48 to notch position 00
without stopping at the intermediate
positions. However, GE Nuclear Energy
recommends that operators insert rods
in the same order as specified for the
original/standard BPWS as much as is
reasonably possible. If a plant is in the
process of shutting down following
improved BPWS with the power below
the LPSP, no control rod shall be
withdrawn unless the control rod
pattern is in compliance with standard
BPWS requirements.
In addition to the procedure changes
specified above, the staff previously
concluded, based on its review of
NEDO–33091–A, that no single failure
of the boiling water reactor control rod
drive (CRD) mechanical or hydraulic
system can cause a control rod to drop
completely out of the reactor core
during the shutdown process. Therefore,
the proper use of the improved BPWS
will prevent a CRDA from occurring
while power is below the LPSP.
[LICENSEE] has verified, in accordance
VerDate Aug<31>2005
18:32 May 22, 2007
Jkt 211001
with NEDO–33091–A, Revision 2, that
no single failure of the boiling water
reactor CRD mechanical or hydraulic
system can cause a control rod to drop
completely out of the reactor core
during the shutdown process.
6.0 No Significant Hazards
Consideration
[LICENSEE] has reviewed the
proposed no significant hazards
consideration determination published
on [DATE] ([ ] FR [ ]) as part of the
CLIIP. [LICENSEE] has concluded that
the proposed determination presented
in the notice is applicable to [PLANT]
and the determination is hereby
incorporated by reference to satisfy the
requirements of 10 CFR 50.91(a).
7.0 Environmental Evaluation
[LICENSEE] has reviewed the
environmental consideration included
in the model SE published on [DATE]
([ ] FR [ ]) as part of the CLIIP.
[LICENSEE] has concluded that the
staff’s findings presented therein are
applicable to [PLANT] and the
determination is hereby incorporated by
reference for this application.
8.0 References
Federal Register Notices:
Notice for Comment published on
[DATE] ([ ] FR [ ])
Notice of Availability published on
[DATE ] ([ ] FR [ ])
Model Safety Evaluation, U.S. Nuclear
Regulatory Commission, Office of
Nuclear Reactor Regulation, Technical
Specification Task Force TSTF–476,
Revision 1, ‘‘Improved BPWS Control
Rod Insertion Process (NEDO–33091)’’
1.0 Introduction
By letter dated [llll, 20l],
[LICENSEE] (the licensee) proposed
changes to the technical specifications
(TS) for [PLANT NAME]. The requested
changes are the adoption of TSTF–476,
Revision 1, ‘‘Improved BPWS Control
Rod Insertion Process (NEDO–33091–
A),’’ to the Boiling Water Reactor (BWR)
Standard Technical Specifications
(STS), which was proposed by the
Technical Specifications Task Force
(TSTF) by letter on January 9, 2007.
This TSTF involves changes to NUREG–
1433 and NUREG–1434 Section 3.1.6
‘‘Rod Pattern Control,’’ Section 3.3.2.1
‘‘Control Rod Block Instrumentation,’’
and Table 3.3.2.1–1. The proposed
TSTF would allow the use of the
improved banked position withdrawal
sequence (BPWS) during shutdowns if
the conditions of NEDO–33091–A,
Revision 2, ‘‘Improved BPWS Control
Rod Insertion Process,’’ dated July 2004,
have been satisfied.
PO 00000
Frm 00064
Fmt 4703
Sfmt 4703
2.0
Regulatory Evaluation
The control rod drop accident (CRDA)
is the design basis accident for the
subject TS changes. In order to
minimize the impact of a CRDA, the
BPWS process was developed to
minimize control rod reactivity worth
for BWR plants. The proposed improved
BPWS further simplifies the control rod
insertion process, and in order to
evaluate it, the staff followed the
guidelines of Standard Review Plan
Section 15.4.9, and referred to General
Design Criterion (GDC) 28 of Appendix
A to 10 CFR Part 50 as its regulatory
requirement. GDC 28 states that the
reactivity control systems shall be
designed with appropriate limits on the
potential amount and rate of reactivity
increase to assure that the effects of
postulated reactivity accidents can
neither (1) result in damage to the
reactor coolant pressure boundary
greater than limited local yielding nor
(2) sufficiently disturb the core, its
support structures or other reactor
pressure vessel internals to impair
significantly the capability to cool the
core.
3.0
Technical Evaluation
In its safety evaluation for Licensing
Topical Report NEDO–33091-A,
‘‘Improved BPWS Control Rod Insertion
Process,’’ dated June 16, 2004, (ADAMS
ML041700479) the staff determined that
the methodology described in TSTF–
476, Revision 1, to incorporate the
improved BPWS into the STS, is
acceptable.
TSTF–476, Revision 1 states that the
improved BPWS provides the following
benefits: (1) Allows the plant to reach
the all-rods-in condition prior to
significant reactor cool down, which
reduces the potential for re-criticality as
the reactor cools down; (2) reduces the
potential for an operator reactivity
control error by reducing the total
number of control rod manipulations;
(3) minimizes the need for manual
scrams during plant shutdowns,
resulting in less wear on control rod
drive (CRD) system components and
CRD mechanisms; and, (4) eliminates
unnecessary control rod manipulations
at low power, resulting in less wear on
reactor manual control and CRD system
components.
[PLANT NAME] has been approved to
use the improved BPWS, and the
potential for a CRDA with power below
the low power setpoint (LPSP) has been
eliminated. The safety evaluation for
NEDO–33091–A explained that the
potential for the CRDA will be
eliminated by the following changes to
operational procedures, which [PLANT
E:\FR\FM\23MYN1.SGM
23MYN1
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Notices
NAME] [has made/will commit to make
prior to implementation]:
1. Before reducing power to the LPSP,
operators shall confirm control rod
coupling integrity for all rods that are
fully withdrawn. Control rods that have
not been confirmed coupled and are in
intermediate positions must be fully
inserted prior to power reduction to the
LPSP. No action is required for fullyinserted control rods.
If a shutdown is required and all rods,
which are not confirmed coupled,
cannot be fully inserted prior to power
dropping below the LPSP, then the
original/standard BPWS must be
adhered to.
2. After reactor power drops below
the LPSP, rods may be inserted from
notch position 48 to notch position 00
without stopping at the intermediate
positions. However, GE Nuclear Energy
recommends that operators insert rods
in the same order as specified for the
original/standard BPWS as much as
reasonably possible. If a plant is in the
process of shutting down following
improved BPWS with the power below
the LPSP, no control rod shall be
withdrawn unless the control rod
pattern is in compliance with standard
BPWS requirements.
In addition to the procedure changes
specified above, the staff previously
verified during its review of NEDO–
33091–A, Revision 2 that no single
failure of the boiling water reactor CRD
mechanical or hydraulic system can
cause a control rod to drop completely
out of the reactor core during the
shutdown process. Therefore, the proper
use of the improved BPWS will prevent
a CRDA from occurring while power is
below the LPSP.
The staff finds the proposed
Technical Specification changes in
[PLANT NAME’s] amendment request
properly incorporate the improved
BPWS procedure into the STS, and that
[PLANT NAME] accurately adopted the
TSTF–476 changes. Therefore, the staff
approves the [PLANT NAME] license
amendment request to adopt TSTF–476,
Revision 1.
pwalker on PROD1PC71 with NOTICES
4.0 State Consultation
In accordance with the Commission’s
regulations, the [llll] State official
was notified of the proposed issuance of
the amendment. The State official had
[(1) no comments or (2) the following
comments—with subsequent
disposition by the staff].
5.0 Environmental Consideration
The amendment[s] change[s] a
requirement with respect to the
installation or use of a facility
component located within the restricted
VerDate Aug<31>2005
18:32 May 22, 2007
Jkt 211001
area as defined in 10 CFR Part 20 or
surveillance requirements. The NRC
staff has determined that the
amendment involves no significant
increase in the amounts, and no
significant change in the types, of any
effluents that may be released offsite,
and that there is no significant increase
in individual or cumulative
occupational radiation exposure. The
Commission has previously issued a
proposed finding that the amendment
involves no significant hazards
consideration and there has been no
public comment on such finding
published [DATE] ([ ] FR [ ]).
Accordingly, the amendment meets the
eligibility criteria for categorical
exclusion set forth in 10 CFR
51.22(c)(9). Pursuant to 10 CFR 51.22(b),
no environmental impact statement or
environmental assessment need be
prepared in connection with the
issuance of the amendment.
6.0
Conclusion
The Commission has concluded,
based on the considerations discussed
above, that (1) There is reasonable
assurance that the health and safety of
the public will not be endangered by
operation in the proposed manner, (2)
such activities will be conducted in
compliance with the Commission’s
regulations, and (3) the issuance of the
amendment will not be inimical to the
common defense and security or to the
health and safety of the public.
Principal Contributor: J. Hardy, SRXB/
DSSA, 301–415–4029.
Proposed No Significant Hazards
Consideration Determination
Description of Amendment Request:
[Plant name] requests adoption of an
approved change to the standard
technical specifications (STS) for
Boiling Water Reactor (BWR) Plants
(NUREG–1433 & NUREG–1434) and
plant specific technical specifications
(TS), to allow the use of the improved
banked position withdrawal sequence
(BPWS) during shutdowns in
accordance with NEDO–33091–A,
Revision 2, ‘‘Improved BPWS Control
Rod Insertion Process,’’ dated July 2004.
The changes are consistent with NRC
approved Industry/Technical
Specification Task Force (TSTF)
Standard Technical Specification
Change Traveler, TSTF–476, Revision 1.
Basis for proposed no-significanthazards-consideration determination:
As required by 10 CFR 50.91(a), an
analysis of the issue of no-significanthazards-consideration is presented
below:
PO 00000
Frm 00065
Fmt 4703
Sfmt 4703
29009
Criterion 1—The Proposed Change Does
Not Involve a Significant Increase in the
Probability or Consequences of an
Accident Previously Evaluated
The proposed changes modify the TS
to allow the use of the improved banked
position withdrawal sequence (BPWS)
during shutdowns if the conditions of
NEDO–33091–A, Revision 2, ‘‘Improved
BPWS Control Rod Insertion Process,’’
July 2004, have been satisfied. The staff
finds that the licensee’s justifications to
support the specific TS changes are
consistent with the approved topical
report and TSTF–476, Revision 1. Since
the change only involves changes in
control rod sequencing, the probability
of an accident previously evaluated is
not significantly increased, if at all. The
consequences of an accident after
adopting TSTF–476 are no different
than the consequences of an accident
prior to adopting TSTF–476. Therefore,
the consequences of an accident
previously evaluated are not
significantly affected by this change.
Therefore, this change does not involve
a significant increase in the probability
or consequences of an accident
previously evaluated.
Criterion 2—The Proposed Change Does
Not Create the Possibility of a New or
Different Kind of Accident from any
Previously Evaluated
The proposed change will not
introduce new failure modes or effects
and will not, in the absence of other
unrelated failures, lead to an accident
whose consequences exceed the
consequences of accidents previously
evaluated. The control rod drop
accident (CRDA) is the design basis
accident for the subject TS changes.
This change does not create the
possibility of a new or different kind of
accident from an accident previously
evaluated.
Criterion 3—The Proposed Change Does
Not Involve a Significant Reduction in
the Margin of Safety
The proposed change, TSTF–476,
Revision 1, incorporates the improved
BPWS, previously approved in NEDO–
33091–A, into the improved TS. The
control rod drop accident (CRDA) is the
design basis accident for the subject TS
changes. In order to minimize the
impact of a CRDA, the BPWS process
was developed to minimize control rod
reactivity worth for BWR plants. The
proposed improved BPWS further
simplifies the control rod insertion
process, and in order to evaluate it, the
staff followed the guidelines of Standard
Review Plan Section 15.4.9, and referred
to General Design Criterion 28 of
E:\FR\FM\23MYN1.SGM
23MYN1
29010
Federal Register / Vol. 72, No. 99 / Wednesday, May 23, 2007 / Notices
Appendix A to 10 CFR Part 50 as its
regulatory requirement. The TSTF
stated the improved BPWS provides the
following benefits: (1) Allows the plant
to reach the all-rods-in condition prior
to significant reactor cool down, which
reduces the potential for re-criticality as
the reactor cools down; (2) reduces the
potential for an operator reactivity
control error by reducing the total
number of control rod manipulations;
(3) minimizes the need for manual
scrams during plant shutdowns,
resulting in less wear on control rod
drive (CRD) system components and
CRD mechanisms; and (4) eliminates
unnecessary control rod manipulations
at low power, resulting in less wear on
reactor manual control and CRD system
components. The addition of procedural
requirements and verifications specified
in NEDO–33091–A, along with the
proper use of the BPWS will prevent a
control rod drop accident (CRDA) from
occurring while power is below the low
power setpoint (LPSP). The net change
to the margin of safety is insignificant.
Therefore, this change does not involve
a significant reduction in a margin of
safety.
Based upon the above discussion of
the amendment request, the requested
change does not involve a significant
hazards consideration.
Dated at Rockville, Maryland, this 10th day
of May 2007.
For the Nuclear Regulatory Commission.
Timothy J. Kobetz,
Branch Chief, Technical Specifications
Branch, Division of Inspection & Regional
Support, Office of Nuclear Reactor
Regulation.
[FR Doc. 07–2563 Filed 5–22–07; 8:45 am]
BILLING CODE 7590–01–P
NUCLEAR REGULATORY
COMMISSION
Addresses
Proposed Generic Communication;
Managing Gas Intrusion in Emergency
Core Cooling, Decay Heat Removal,
and Containment Spray Systems
Nuclear Regulatory
Commission.
AGENCY:
Notice of opportunity for public
comment.
pwalker on PROD1PC71 with NOTICES
ACTION:
SUMMARY: The U.S. Nuclear Regulatory
Commission (NRC) is proposing to issue
a generic letter (GL) to address the issue
of gas intrusion into the emergency core
cooling, decay heat removal, and
containment spray systems (hereinafter
referred to as the ‘‘subject systems’’).
Specifically, the NRC is issuing this GL
for the following two purposes:
VerDate Aug<31>2005
18:32 May 22, 2007
(1) to request addressees to submit
information demonstrating that the
subject systems are in compliance with
the current licensing and design bases,
and applicable regulatory requirements,
and that suitable design, operational,
and testing control measures are in
place for maintaining this compliance,
and
(2) to collect the requested
information to determine if additional
regulatory action is required.
This Federal Register notice is
available through the NRC’s
Agencywide Documents Access and
Management System (ADAMS) under
accession number ML0704001003.
DATES: Comment period expires July 23,
2007. Comments submitted after this
date will be considered if it is practical
to do so, but assurance of consideration
cannot be given except for comments
received on or before this date.
ADDRESSES: Submit written comments
to the Chief, Rulemaking, Directives,
and Editing Branch, Division of
Administrative Services, Office of
Administration, U.S. Nuclear Regulatory
Commission, Mail Stop T6–D59,
Washington, DC 20555–0001, and cite
the publication date and page number of
this Federal Register notice. Written
comments may also be delivered to NRC
Headquarters, 11545 Rockville Pike
(Room T–6D59), Rockville, Maryland,
between 7:30 a.m. and 4:15 p.m. on
Federal workdays.
FOR FURTHER INFORMATION, CONTACT:
Warren C. Lyon, NRR, at 301–415–2897
or by e-mail: wcl@nrc.gov or David P.
Beaulieu, NRR, at 301–415–3243 or by
e-mail: dpb@nrc.gov.
SUPPLEMENTARY INFORMATION:
NRC Generic Letter 2007–XX,
Managing Gas Intrusion in Emergency
Core Cooling, Decay Heat Removal, and
Containment Spray Systems
Jkt 211001
All holders of operating licenses for
nuclear power reactors, except those
who have permanently ceased
operations and have certified that fuel
has been permanently removed from the
reactor vessel.
Purpose
The U.S. Nuclear Regulatory
Commission (NRC) is issuing this
generic letter (GL) to address the issue
of gas 1 intrusion into the emergency
core cooling, decay heat removal 2, and
1 Gas as used here includes, air, nitrogen,
hydrogen, water vapor, or any other void that is not
filled with liquid water.
2 Decay heat removal (DHR), residual heat
removal (RHR), and shutdown cooling (SDC) are
common names for systems used to cool the reactor
PO 00000
Frm 00066
Fmt 4703
Sfmt 4703
containment spray systems (hereinafter
referred to as the ‘‘subject systems’’).
Specifically, the NRC is issuing this GL:
(1) To request addressees to submit
information to demonstrate that the
subject systems are in compliance with
the current licensing and design bases
and applicable regulatory requirements,
and that suitable design, operational,
and testing control measures are in
place for maintaining this compliance,
and
(2) to collect the requested
information to determine if additional
regulatory action is required.
Pursuant to Title 10 of the Code of
Federal Regulations (10 CFR) Section
50.54(f), addressees are required to
submit a written response to this GL.
Background
Instances of gas intrusion into the
subject systems have occurred since the
beginning of commercial nuclear power
plant operation. The NRC has published
20 information notices (INs), two GLs,
and a NUREG 3 that are related to this
issue and has interacted with the
nuclear industry many times in relation
to these publications and in response to
gas intrusion events. The following
paragraphs summarize a few events to
illustrate some of the technical and
regulatory requirements issues.
In May 1997, at Oconee Nuclear
Station Unit 3, hydrogen ingestion
during plant cooldown damaged and
rendered nonfunctional two highpressure injection (HPI) pumps. If the
operators had started the remaining HPI
pump, it too would have been damaged.
The NRC responded with an augmented
inspection team (IN 97–38, ‘‘LevelSensing System Initiates Common-Mode
Failure of High-Pressure-Injection
Pumps,’’ Agencywide Documents
Access and Management System
(ADAMS) Accession No. ML031050514,
June 24, 1997). The NRC team reported
that there had been a total lack of HPI
capability during power operation, a
failure to meet technical specification
(TS) HPI operability requirements,
design deficiencies, inadequate
maintenance practices, operators that
were less than attentive to plant
parameters, a failure to adequately
assess operating experience, and a
violation of 10 CFR part 50, Appendix
coolant system (RCS) during some phases of
shutdown operation. The NRC staff generally uses
DHR here.
3 GL 88–17, ‘‘Loss of Decay Heat Removal,’’
October 17, 1988 (ML031200496); GL 97–04,
‘‘Assurance of Sufficient Net Positive Suction Head
for Emergency Core Cooling and Containment Heat
Removal Pumps,’’ October 7, 1997 (ML031110062);
and NUREG–0897, Revision 1, ‘‘Containment
Emergency Sump Performance—Technical Findings
Related to USI A–43,’’ October 1985.
E:\FR\FM\23MYN1.SGM
23MYN1
Agencies
[Federal Register Volume 72, Number 99 (Wednesday, May 23, 2007)]
[Notices]
[Pages 29004-29010]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 07-2563]
-----------------------------------------------------------------------
NUCLEAR REGULATORY COMMISSION
Notice of Availability of Model Safety Evaluation and Model
License Amendment Request on Technical Specification Improvement
Regarding Use of the Improved Banked Position Withdrawal Sequence for
General Electric Boiling Water Reactors Using the Consolidated Line
Item Improvement Process
AGENCY: Nuclear Regulatory Commission.
ACTION: Request for comment.
-----------------------------------------------------------------------
SUMMARY: Notice is hereby given that the staff of the U. S. Nuclear
Regulatory Commission (NRC) has prepared a model license amendment
request (LAR), model safety evaluation (SE), and model proposed no
significant hazards consideration (NSHC) determination related to
changes to Standard Technical Specification (STS) 3.1.6, ``Rod Pattern
Control,'' and STS 3.3.2.1, ``Control Rod Block Instrumentation'' for
NUREG-1433 and NUREG-1434. The proposed changes would revise the
Technical Specifications (TS) and Bases for STS 3.1.6, ``Rod Pattern
Control,'' and STS 3.3.2.1, ``Control Rod Block Instrumentation'' to
allow licensees to use an improved control rod banked position
withdrawal sequence (BPWS) when performing a reactor shutdown. In
addition, the proposed changes would add a footnote to Table 3.3.2.1-1,
``Control Rod Block Instrumentation'' for NUREG-1433 and NUREG-1434.
The requirements for implementing the improved BPWS are described in
General Electric Licensing Topical Report (LTR) NEDO-33091-A, Revision
2, ``Improved BPWS Control Rod Insertion Process,'' dated July 2004.
The General Electric Boiling Water Reactor Owner's Group (BWROG)
participants in the Technical Specifications Task Force (TSTF)
initially proposed these changes to the STS in TSTF-476, Revision 0,
``Improved BPWS Control Rod Insertion Process (NEDO-33091).'' TSTF-476,
Revision 1 was submitted on January 9, 2007 and was later accepted by
NRC. Hereafter, all references to TSTF-476 refer to TSTF-476, Revision
1, unless otherwise noted. Technical
[[Page 29005]]
Specifications and Bases changes provided in TSTF-476 completely
supersede the proposed Technical Specification changes included in
NEDO-3309 1-A.
The purpose of these models is to permit the NRC to efficiently
process amendments to incorporate these changes into plant-specific
(TS) for General Electric Boiling Water Reactors (BWRs). Licensees of
nuclear power reactors to which the models apply can request amendments
conforming to the models. In such a request, a licensee should confirm
the applicability of the model LAR, model SE and NSHC determination to
its plant.
DATES: The NRC staff issued a Federal Register Notice (71 FR 26118, May
3, 2006) which provided for public comment a model SE, model LAR, and
NSHC determination related to changes to STS 3.1.6, ``Rod Pattern
Control,'' and STS 3.3.2.1, ``Control Rod Block Instrumentation'' for
NUREG-1433 and NUREG-1434. Similarly, the NRC staff herein provides a
revised model SE, revised model LAR, and NSHC determination. The NRC
staff can most efficiently consider applications based upon the model
LAR, which references the Model SE, if the application is submitted
within one year of this Federal Register Notice.
FOR FURTHER INFORMATION CONTACT: Timothy Kobetz, Mail Stop: O-12H2,
Division Inspection and Regional Support, Office of Nuclear Reactor
Regulation, U.S. Nuclear Regulatory Commission, Washington, DC 20555-
0001, telephone 301-415-1932.
SUPPLEMENTARY INFORMATION:
Background
Regulatory Issue Summary 2000-06, ``Consolidated Line Item
Improvement Process (CLIIP) for Adopting Standard Technical
Specifications Changes for Power Reactors,'' was issued on March 20,
2000. The CLIIP is intended to improve the efficiency and transparency
of NRC licensing processes. This is accomplished by processing proposed
changes to the STS in a manner that supports subsequent license
amendment applications. The CLIIP includes an opportunity for the
public to comment on proposed changes to the STS following a
preliminary assessment by the NRC staff and finding that the change
will likely be offered for adoption by licensees.
The CLIIP directs the NRC staff to evaluate any comments received
for a proposed change to the STS and to either reconsider the change or
proceed with announcing the availability of the change for proposed
adoption by licensees. In several instances, the staff's evaluation did
result in changes to the model LAR. Those licensees opting to apply for
the subject change to TS are responsible for reviewing the staff's
evaluation, referencing the applicable technical justifications, and
providing any necessary plant-specific information. The model LAR shows
licensees the expected level of detail that needs to be included in
order to adopt TSTF-476, as well as guidelines for staff review. The
NRC has established an internal review plan that designates the
appropriate staff and approximate time lines to review plant-specific
LARs that reference TSTF-476. Each amendment application made in
response to the notice of availability will be processed and noticed in
accordance with applicable NRC rules and procedures.
This notice involves implementation of an improved BPWS, which
allows licensees of General Electric BWRs to follow the improved BPWS
when inserting control rods into the core during a reactor shutdown. By
letter dated January 9, 2007, the BWROG proposed these changes for
incorporation into the STS as TSTF-476. These changes are based on the
NRC staff-approved LTR NEDO-33091-A, ``Improved BPWS Control Rod
Insertion Process,'' dated July 2004, as approved by NRC in a SE dated
June 16, 2004, accessible electronically from the Agency-wide Documents
Access and Management System's (ADAMS) Public Electronic Reading Room
on the Internet (ADAMS Accession No. ML041700479) at the NRC Web site
https://www.nrc.gov/reading-rm/adams.html. Persons who do not have
access to ADAMS or who encounter problems in accessing the documents
located in ADAMS, should contact the NRC Public Document Room Reference
staff by telephone at 1-800-397-4209, 301-415-4737, or by e-mail to
pdr@nrc.gov.
Applicability
These changes revise the Section 3.1.6 and Section 3.3.2.1 TS and
Bases for NUREG-1433 and NUREG-1434 (General Electric BWR/4 and BWR/6
plants, respectively), and TS Table 3.3.2.1-1 for NUREG-1433 and NUREG-
1434.
To efficiently process the incoming license amendment applications,
the NRC staff requests each licensee applying for the changes addressed
by TSTF-476 use the CLIIP to submit a LAR that adheres to the following
model. Any deviations from the model LAR should be explained in the
licensee's submittal. The CLIIP does not prevent licensees from
requesting an alternative approach, proposing the changes without
providing the information described in the eight model LAR conditions,
or making the requested commitment. Variations from the approach
recommended in this notice may, however, require additional review by
the NRC staff and may increase the time and resources needed for the
review. Significant variations from the approach, or inclusion of
additional changes to the license, may result in staff rejection of the
submittal. Instead, licensees desiring significant variations and/or
additional changes should either submit a LAR that does not claim to
adopt TSTF-476, or specifically state in their LAR that they are
adopting TSTF-476 without using the CLIIP.
Public Notices
In a notice in the Federal Register dated May 3, 2006 (71 FR
26118), the staff requested comment on the use of the CLIIP to process
requests to revise Section 3.1.6 and Section 3.3.2.1 TS and Bases and
TS Table 3.3.2.1-1 for NUREG-1433 and NUREG-1434, as discussed in TSTF-
476. In response to this notice, the staff received one set of comments
(developed by the Technical Specifications Task Force and submitted in
a letter dated May 31, 2006 (ADAMS Accession No. ML061520129)).
Specific comments on the model LAR were offered. These comments, along
with the NRC staff's responses, are summarized and discussed below:
1. Comment: In the Applicability Section of the Notice and the
model application, the terms ``BWR/4'' and ``BWR/6'' are used
incorrectly. These terms should be revised to NUREG-1433 and NUREG-
1434, respectively. The changes proposed are applicable to BWR/2-6
plants, if they have adopted the standard banked position withdrawal
sequence (BPWS). TSTF-476 proposes changes to the Improved Standard
Technical Specifications (ISTS) included in NUREG-1433 and NUREG-1434,
which may be applied to any BWR type.
Response: The staff agrees with this comment. References to BWR/4
and BWR/6 have been replaced with NUREG-1433 and NUREG-1434,
respectively.
2. Comment: The notice, the model application, and the model Safety
Evaluation imply that a license amendment is needed for plants with
Technical Specifications based on NUREG-1433 to adopt TSTF-476. This is
not correct. No license amendment request is required to adopt the
proposed Bases changes included in TSTF-476 and no Technical
[[Page 29006]]
Specification change is needed to adopt TSTF-476 for plants with
Technical Specifications based on NUREG-1433. Bases changes are made
using the licensee Technical Specification Bases Control Program.
Response: The changes proposed by TSTF-476, Revision 0, for NUREG-
1433 (BWR/4) were only changes to the Bases sections. However, a
revised TSTF-476 was submitted to the NRC on January 9, 2007. The
revised version of TSTF-476 includes changes to the Technical
Specifications and Bases sections for both NUREG-1433 (BWR/4) and
NUREG-1434 (BWR/6). Therefore, licensees proposing to adopt TSTF-476
are required to submit a license amendment request.
3. Comment: In some BWR designs, the rod worth minimizers (RWMs)
(e.g., NUMAC) cannot be reprogrammed to accept a new shutdown sequence.
The notice should state that bypassing the RWM and entering the plant-
specific action equivalent to NUREG-1433 Specification 3.3.2.1,
Required Action D. 1, for an inoperable RWM during shutdown (which
requires the use of a second qualified person to verify rod movement in
accordance with BPWS) is acceptable and would not be considered
entering a Required Action for ``operational convenience'' as discussed
in the LCO 3.0.2 Bases.
Response: During the comment disposition process it became apparent
that revisions to TSTF-476 would be necessary. The changes proposed in
TSTF-476, Revision 0, included bases changes to both NUREG-1433 (BWR/4)
and NUREG-1434 (BWR/6). In addition, a note was proposed to be added to
TS Table 3.3.2.1-1 of NUREG-1434 to allow the rod pattern controller to
be bypassed in Modes 1 and 2 so that the BPWS can be used. A similar
note was not included in NUREG-1433 since some BWR/4 plants rod worth
minimizer (RWM) can be reprogrammed to accommodate the BPWS. However,
the RWM of some BWR/4 plants cannot be reprogrammed to accommodate the
BPWS, and need a similar note to that proposed for the BWR/6 NUREG-
1434. Therefore, to be acceptable, a [bracketed] note similar to that
proposed to be added to TS Table 3.3.2.1-1 of the BWR/6 NUREG-1434, was
incorporated into TSTF-476, revision 1. A revised TSTF-476 was
submitted to the NRC on January 9, 2007. The changes incorporated in
the revised version of TSTF-476 include changes to the Technical
Specifications and Bases sections that require the adopting licensee to
submit a license amendment request.
4. Comment: The notice should state that the Technical
Specifications and Bases changes provided in TSTF-476 completely
supersede the proposed Technical Specification changes included in
NEDO-3309 1-A.
Response: An appropriate statement has been added in this notice.
5. Comment: Throughout the notice, the acronym BPWS is defined
incorrectly. The term BPWS stands for ``Banked Position Withdrawal
Sequence,'' not ``Bank Position Withdrawal Sequence.''
Response: Appropriate corrections have been made throughout the
notice and its attachments.
6. Comment: Cover letter, 1st paragraph--The license amendment
request will revise Table 3.3.2.1-1 only. The associated Bases changes
will be made by the licensee upon implementation using the Technical
Specifications Bases Control Program. This also affects Sections I and
2 of Enclosure I.
Response: The changes incorporated in TSTF-476 include changes to
the Technical Specifications and Bases sections that are needed by the
adopting licensee to submit a license amendment request. While the
Bases remain subject to licensee control, a more timely review will be
possible if the licensee requesting to adopt the changes includes
Technical Specification Bases changes in its application.
7. Comment: Cover letter, 3rd paragraph--Many licensees do not
provide final Technical Specifications pages with the application. The
final pages are provided only after NRC review has determined that no
changes from the draft are required. Revised Bases pages are not
required to be provided with an application. The Technical
Specification Bases Control Program requires revised Bases pages to be
provided to the NRC on a frequency consistent with 10 CFR 50.71(e).
Response: While the Bases remain subject to licensee control, for
this application the NRC staff plans to review marked-up Technical
Specification and Technical Specification Bases pages, as well as pages
that represent how the final Technical Specification and Technical
Specification Bases pages will appear, in order to review a licensee's
license amendment application in the most timely manner.
8. Comment: Enclosure 1, Section 2.0, Proposed Changes, the first
bullet should reference the Bases for Specification 3.1.6, not 3.6.1,
if the discussion of specific Bases changes is retained in this
section.
Response: Appropriate corrections of the errors have been made to
the model.
9. Comment: Enclosure 1, Section 2.0, Proposed Changes, the second
bullet should discuss the rod pattern controller, not the rod worth
minimizer, if the discussion of specific Bases changes is retained in
this section. In addition, both bypassing and reprogramming should be
discussed.
Response: TSTF-476, revision 0 called for changes to Technical
Specification Section 3.3.2.1 Bases for NUREG-1434. TSTF-476, revision
1 calls for changes to Technical Specification Section 3.3.2.1 Bases
for both NUREG-1433 and NUREG-1434. The specific equipment nomenclature
differs between the two standards. The model has been updated using the
bracketing convention to allow the selection of the appropriate
equipment nomenclature by the licensee prior to amendment application.
10. Comment: Enclosure 1, Section 5.1, the last sentence should be
deleted. The NRC staff has already determined in the Safety Evaluation
for NEDO-33091 for all BWRs that no single failure of the boiling water
reactor mechanical or hydraulic system can cause a control rod to drop
completely out of the reactor core during the shutdown process. It is
unnecessary and a burden with no safety benefit to require individual
licensees to verify the statement when it has been generically approved
by the NRC for all BWRs.
Response: The staff's approval and safety evaluation are predicated
upon this determination, and the licensee's verification is deemed
essential.
11. Comment: In Enclosure 1, Section 5.1 and in the model Safety
Evaluation, Section 3.0, commitment 1 should be deleted. For those
plants with Technical Specifications based on NUREG-1434 which will be
submitting a license amendment request to adopt TSTF-476, the proposed
change to Table 3.3.2. 1-1 requires confirming control rod coupling
integrity; therefore a separate commitment to do the same is not
necessary.
Response: This is a commitment to establish appropriate detailed
operational procedures prior to implementation, and is deemed
essential.
12. Comment: Enclosure 1, Section 5. 1, and in the model Safety
Evaluation, Section 3.0 commitment 2 should be deleted. This
``commitment'' is a summary of the improved BPWS. The model amendment,
the model Safety Evaluation, and the proposed Bases reference the NRC
approved Topical Report as the basis for the improved BPWS sequence. It
is unclear what is
[[Page 29007]]
required by this commitment that is not already required by adoption of
the Technical Specifications and Bases. It is unnecessary to develop
and track a separate regulatory commitment to do what is already
required by the amendment and Topical Report.
Response: This is a commitment to establish appropriate detailed
operational procedures prior to implementation, and is deemed
essential.
13. Comment: Description--Amendment requests will only be submitted
by licensees with Technical Specifications based on NUREG-1434.
Therefore, delete references to NUREG-1433.
Response: BWR/4 plants with a RWM that cannot be reprogrammed to
accommodate the BPWS will need to amend their TS in order to adopt
TSTF-476. Therefore, references to NUREG-1433 are not deleted.
14. Comment: Description and Criterion I--The improved BPWS
insertion process applies during reactor shutdowns. Delete the word
``normal'' before shutdown. The term ``normal shutdown'' is not used in
the model Safety Evaluation or Topical Report. The improved BPWS
insertion process applies to all shutdowns as long as the conditions
for use are met.
Response: The word ``normal'' has been removed as a modifier for
the term ``shutdown'' in applicable sections of the model.
15. Comment: Criterion 2--Delete the phrase ``in the absence of
other unrelated failures'' from the first sentence. Criterion 2 only
evaluates the possibility of a new or different kind of accident
related to the proposed change, not other unrelated events.
Response: The extraneous phrase has been removed from the model SE.
For Inclusion on the Technical Specification Web Page the following
example of an application was prepared by the NRC staff to facilitate
the adoption of Technical Specifications Task Force (TSTF) Traveler
TSTF-476, Revision 1 ``Improved BPWS Control Rod Insertion Process
(NEDO-33091).'' The model provides the expected level of detail and
content for an application to adopt TSTF-476, Revision 1. Licensees
remain responsible for ensuring that their actual application fulfills
their administrative requirements as well as NRC regulations.
U.S. Nuclear Regulatory Commission, Document Control Desk,
Washington, DC 20555.
Subject: Plant Name, Docket No. 50-[xxx,] Re: Application for
Technical Specification Improvement To Adopt TSTF-476, Revision 1,
``Improved BPWS Control Rod Insertion Process (NEDO-33091)
Dear Sir or Madam: In accordance with the provisions of Section
50.90 of Title 10 of the Code of Federal Regulations (10 CFR),
[LICENSEE] is submitting a request for an amendment to the technical
specifications (TS) for [PLANT NAME, UNIT NOS.].
The proposed changes would revise Sections 3.1.6, ``Rod Pattern
Control,'' and 3.3.2.1, ``Control Rod Block Instrumentation,'' to
allow [PLANT NAME] to reference a new Banked Position Withdrawal
Sequence (BPWS) shutdown sequence in the TS Bases. In addition, a
footnote is added to Table 3.3.2.1-1, ``Control Rod Block
Instrumentation.''
The changes are consistent with NRC approved Industry Technical
Specification Task Force (TSTF) Standard Technical Specification
Change Traveler, TSTF-476, Revision 1, Improved BPWS Control Rod
Insertion Process (NEDO-33091).'' The availability of this TS
improvement was announced in the Federal Register on [DATE] ([ FR ])
as part of the consolidated line item improvement process (CLIIP).
Enclosure 1 provides a description and assessment of the
proposed changes, as well as confirmation of applicability.
Enclosure 2 provides the existing TS pages and TS Bases marked-up to
show the proposed changes. Enclosure 3 provides final TS pages and
TS Bases pages.
[LICENSEE] requests approval of the proposed license amendment
by [DATE], with the amendment being implemented [BY DATE OR WITHIN X
DAYS]. In accordance with 10 CFR 50.91, a copy of this application,
with enclosures, is being provided to the designated [STATE]
Official.
I declare under penalty of perjury under the laws of the United
States of America that I am authorized by [LICENSEE] to make this
request and that the foregoing is true and correct. [Note that
request may be notarized in lieu of using this oath or affirmation
statement]. If you should have any questions regarding this
submittal, please contact [ ].
Sincerely,
Name, Title
Enclosures:
1. Description and Assessment of Proposed Changes
2. Proposed Technical Specification Changes and Technical
Specification Bases Changes
3. Final Technical Specification and Bases pages.
cc: NRR Project Manager, Regional Office, Resident Inspector, State
Contact, ITSB Branch Chief.
1.0 Description
This letter is a request to amend Operating License(s) [LICENSE
NUMBER(S)] for [PLANT/UNIT NAME(S)].
The proposed changes would revise the Bases sections of Technical
Specification (TS) 3.1.6, ``Rod Pattern Control'', and 3.3.2.1,
``Control Rod Block Instrumentation,'' along with TS Table 3.3.2.1-1,
``Control Rod Block Instrumentation,'' to allow reference to an
improved, optional Banked Position Withdrawal Sequence (BPWS) for use
during reactor shutdown.
The new BPWS is described in Topical Report NEDO-33091-A, Revision
2, ``Improved BPWS Control Rod Insertion Process,'' dated July 2004,
and approved by the NRC by Safety Evaluation (SE) dated June 16, 2004
(ADAMS ML041700479). Technical Specification Task Force (TSTF) change
traveler TSTF-476, Revision 1, ``Improved BPWS Control Rod Insertion
Process (NEDO-33091)'' was announced for availability in the Federal
Register on [DATE] as part of the consolidated line item improvement
process (CLIIP).
2.0 Proposed Changes
Consistent with NRC-approved TSTF-476, Revision 1, the proposed TS
and Bases changes include:
Revised TS Section 3.1.6 Bases to allow use of an optional
BPWS during plant shutdown.
Revised TS Section 3.3.2.1 Bases to allow reprogramming of
the [rod worth minimizer/rod pattern controller] during the optional
BPWS shutdown sequence.
Revised TS Table 3.3.2.1-1, ``Control Rod Block
Instrumentation,'' which adds a footnote that allows operators to
bypass the [rod worth minimizer/rod pattern controller] if conditions
for the optional BPWS shutdown process are satisfied.
3.0 Background
The background for this application is as stated in the model SE in
NRC's Notice of Availability published on [DATE ]([ ] FR [ ]), the NRC
Notice for Comment published on [DATE] ([ ] FR [ ]), and TSTF-476,
Revision 1.
4.0 Technical Analysis
[LICENSEE] has reviewed NEDO-33091-A, Revision 2, and the staff's
SE dated June 16, 2004, as well as TSTF-476, Revision 1, and the model
SE published on [DATE] ([ ] FR [ ]) as part of the CLIIP Notice for
Comment. [LICENSEE] has applied the methodology in NEDO-33091-A,
Revision 2 to the develop the proposed TS changes. [LICENSEE] has also
concluded that the justifications presented in TSTF-476, Revision 1 and
the model SE prepared by the NRC staff are applicable to [PLANT, UNIT
NOS.], and justify this amendment for the incorporation of the changes
to the [PLANT] TS.
5.0 Regulatory Analysis
A description of this proposed change and its relationship to
applicable regulatory requirements and guidance
[[Page 29008]]
was provided in the NRC Notice of Availability published on [DATE] ([ ]
FR [ ]), the NRC Notice for Comment published on May 3, 2006 (71 FR
26118), and TSTF-476, Revision 1.
5.1 Regulatory Commitments
As discussed in the model SE published in Federal Register on
[DATE] for this technical specification improvement, the following
plant-specific verifications/commitments were performed. The safety
evaluation for NEDO-33091-A explained that the potential for the
control rod drop accident (CRDA) will be eliminated by the following
changes to the operational procedures, which [PLANT NAME] [has made/
will commit to make prior to implementation]:
1. Before reducing power to the low power setpoint (LPSP),
operators shall confirm control rod coupling integrity for all rods
that are fully withdrawn. Control rods that have not been confirmed
coupled and are in intermediate positions must be fully inserted prior
to power reduction to the LPSP. No action is required for fully-
inserted control rods.
If a shutdown is required and all rods, which are not confirmed
coupled, cannot be fully inserted prior to the power dropping below the
LPSP, then the original/standard BPWS must be adhered to. The original/
standard BPWS can be found in Licensing Topical Report (LTR) NEDO-
21231, ``Banked Position Withdrawal Sequence,'' January 1977, and is
referred to in NUREG-1433 and NUREG-1434.
2. After reactor power drops below the LPSP, rods may be inserted
from notch position 48 to notch position 00 without stopping at the
intermediate positions. However, GE Nuclear Energy recommends that
operators insert rods in the same order as specified for the original/
standard BPWS as much as is reasonably possible. If a plant is in the
process of shutting down following improved BPWS with the power below
the LPSP, no control rod shall be withdrawn unless the control rod
pattern is in compliance with standard BPWS requirements.
In addition to the procedure changes specified above, the staff
previously concluded, based on its review of NEDO-33091-A, that no
single failure of the boiling water reactor control rod drive (CRD)
mechanical or hydraulic system can cause a control rod to drop
completely out of the reactor core during the shutdown process.
Therefore, the proper use of the improved BPWS will prevent a CRDA from
occurring while power is below the LPSP. [LICENSEE] has verified, in
accordance with NEDO-33091-A, Revision 2, that no single failure of the
boiling water reactor CRD mechanical or hydraulic system can cause a
control rod to drop completely out of the reactor core during the
shutdown process.
6.0 No Significant Hazards Consideration
[LICENSEE] has reviewed the proposed no significant hazards
consideration determination published on [DATE] ([ ] FR [ ]) as part of
the CLIIP. [LICENSEE] has concluded that the proposed determination
presented in the notice is applicable to [PLANT] and the determination
is hereby incorporated by reference to satisfy the requirements of 10
CFR 50.91(a).
7.0 Environmental Evaluation
[LICENSEE] has reviewed the environmental consideration included in
the model SE published on [DATE] ([ ] FR [ ]) as part of the CLIIP.
[LICENSEE] has concluded that the staff's findings presented therein
are applicable to [PLANT] and the determination is hereby incorporated
by reference for this application.
8.0 References
Federal Register Notices:
Notice for Comment published on [DATE] ([ ] FR [ ])
Notice of Availability published on [DATE ] ([ ] FR [ ])
Model Safety Evaluation, U.S. Nuclear Regulatory Commission, Office of
Nuclear Reactor Regulation, Technical Specification Task Force TSTF-
476, Revision 1, ``Improved BPWS Control Rod Insertion Process (NEDO-
33091)''
1.0 Introduction
By letter dated [--------, 20--], [LICENSEE] (the licensee)
proposed changes to the technical specifications (TS) for [PLANT NAME].
The requested changes are the adoption of TSTF-476, Revision 1,
``Improved BPWS Control Rod Insertion Process (NEDO-33091-A),'' to the
Boiling Water Reactor (BWR) Standard Technical Specifications (STS),
which was proposed by the Technical Specifications Task Force (TSTF) by
letter on January 9, 2007. This TSTF involves changes to NUREG-1433 and
NUREG-1434 Section 3.1.6 ``Rod Pattern Control,'' Section 3.3.2.1
``Control Rod Block Instrumentation,'' and Table 3.3.2.1-1. The
proposed TSTF would allow the use of the improved banked position
withdrawal sequence (BPWS) during shutdowns if the conditions of NEDO-
33091-A, Revision 2, ``Improved BPWS Control Rod Insertion Process,''
dated July 2004, have been satisfied.
2.0 Regulatory Evaluation
The control rod drop accident (CRDA) is the design basis accident
for the subject TS changes. In order to minimize the impact of a CRDA,
the BPWS process was developed to minimize control rod reactivity worth
for BWR plants. The proposed improved BPWS further simplifies the
control rod insertion process, and in order to evaluate it, the staff
followed the guidelines of Standard Review Plan Section 15.4.9, and
referred to General Design Criterion (GDC) 28 of Appendix A to 10 CFR
Part 50 as its regulatory requirement. GDC 28 states that the
reactivity control systems shall be designed with appropriate limits on
the potential amount and rate of reactivity increase to assure that the
effects of postulated reactivity accidents can neither (1) result in
damage to the reactor coolant pressure boundary greater than limited
local yielding nor (2) sufficiently disturb the core, its support
structures or other reactor pressure vessel internals to impair
significantly the capability to cool the core.
3.0 Technical Evaluation
In its safety evaluation for Licensing Topical Report NEDO-33091-A,
``Improved BPWS Control Rod Insertion Process,'' dated June 16, 2004,
(ADAMS ML041700479) the staff determined that the methodology described
in TSTF-476, Revision 1, to incorporate the improved BPWS into the STS,
is acceptable.
TSTF-476, Revision 1 states that the improved BPWS provides the
following benefits: (1) Allows the plant to reach the all-rods-in
condition prior to significant reactor cool down, which reduces the
potential for re-criticality as the reactor cools down; (2) reduces the
potential for an operator reactivity control error by reducing the
total number of control rod manipulations; (3) minimizes the need for
manual scrams during plant shutdowns, resulting in less wear on control
rod drive (CRD) system components and CRD mechanisms; and, (4)
eliminates unnecessary control rod manipulations at low power,
resulting in less wear on reactor manual control and CRD system
components.
[PLANT NAME] has been approved to use the improved BPWS, and the
potential for a CRDA with power below the low power setpoint (LPSP) has
been eliminated. The safety evaluation for NEDO-33091-A explained that
the potential for the CRDA will be eliminated by the following changes
to operational procedures, which [PLANT
[[Page 29009]]
NAME] [has made/will commit to make prior to implementation]:
1. Before reducing power to the LPSP, operators shall confirm
control rod coupling integrity for all rods that are fully withdrawn.
Control rods that have not been confirmed coupled and are in
intermediate positions must be fully inserted prior to power reduction
to the LPSP. No action is required for fully-inserted control rods.
If a shutdown is required and all rods, which are not confirmed
coupled, cannot be fully inserted prior to power dropping below the
LPSP, then the original/standard BPWS must be adhered to.
2. After reactor power drops below the LPSP, rods may be inserted
from notch position 48 to notch position 00 without stopping at the
intermediate positions. However, GE Nuclear Energy recommends that
operators insert rods in the same order as specified for the original/
standard BPWS as much as reasonably possible. If a plant is in the
process of shutting down following improved BPWS with the power below
the LPSP, no control rod shall be withdrawn unless the control rod
pattern is in compliance with standard BPWS requirements.
In addition to the procedure changes specified above, the staff
previously verified during its review of NEDO-33091-A, Revision 2 that
no single failure of the boiling water reactor CRD mechanical or
hydraulic system can cause a control rod to drop completely out of the
reactor core during the shutdown process. Therefore, the proper use of
the improved BPWS will prevent a CRDA from occurring while power is
below the LPSP.
The staff finds the proposed Technical Specification changes in
[PLANT NAME's] amendment request properly incorporate the improved BPWS
procedure into the STS, and that [PLANT NAME] accurately adopted the
TSTF-476 changes. Therefore, the staff approves the [PLANT NAME]
license amendment request to adopt TSTF-476, Revision 1.
4.0 State Consultation
In accordance with the Commission's regulations, the [--------]
State official was notified of the proposed issuance of the amendment.
The State official had [(1) no comments or (2) the following comments--
with subsequent disposition by the staff].
5.0 Environmental Consideration
The amendment[s] change[s] a requirement with respect to the
installation or use of a facility component located within the
restricted area as defined in 10 CFR Part 20 or surveillance
requirements. The NRC staff has determined that the amendment involves
no significant increase in the amounts, and no significant change in
the types, of any effluents that may be released offsite, and that
there is no significant increase in individual or cumulative
occupational radiation exposure. The Commission has previously issued a
proposed finding that the amendment involves no significant hazards
consideration and there has been no public comment on such finding
published [DATE] ([ ] FR [ ]). Accordingly, the amendment meets the
eligibility criteria for categorical exclusion set forth in 10 CFR
51.22(c)(9). Pursuant to 10 CFR 51.22(b), no environmental impact
statement or environmental assessment need be prepared in connection
with the issuance of the amendment.
6.0 Conclusion
The Commission has concluded, based on the considerations discussed
above, that (1) There is reasonable assurance that the health and
safety of the public will not be endangered by operation in the
proposed manner, (2) such activities will be conducted in compliance
with the Commission's regulations, and (3) the issuance of the
amendment will not be inimical to the common defense and security or to
the health and safety of the public.
Principal Contributor: J. Hardy, SRXB/DSSA, 301-415-4029.
Proposed No Significant Hazards Consideration Determination
Description of Amendment Request: [Plant name] requests adoption of
an approved change to the standard technical specifications (STS) for
Boiling Water Reactor (BWR) Plants (NUREG-1433 & NUREG-1434) and plant
specific technical specifications (TS), to allow the use of the
improved banked position withdrawal sequence (BPWS) during shutdowns in
accordance with NEDO-33091-A, Revision 2, ``Improved BPWS Control Rod
Insertion Process,'' dated July 2004. The changes are consistent with
NRC approved Industry/Technical Specification Task Force (TSTF)
Standard Technical Specification Change Traveler, TSTF-476, Revision 1.
Basis for proposed no-significant-hazards-consideration
determination: As required by 10 CFR 50.91(a), an analysis of the issue
of no-significant-hazards-consideration is presented below:
Criterion 1--The Proposed Change Does Not Involve a Significant
Increase in the Probability or Consequences of an Accident Previously
Evaluated
The proposed changes modify the TS to allow the use of the improved
banked position withdrawal sequence (BPWS) during shutdowns if the
conditions of NEDO-33091-A, Revision 2, ``Improved BPWS Control Rod
Insertion Process,'' July 2004, have been satisfied. The staff finds
that the licensee's justifications to support the specific TS changes
are consistent with the approved topical report and TSTF-476, Revision
1. Since the change only involves changes in control rod sequencing,
the probability of an accident previously evaluated is not
significantly increased, if at all. The consequences of an accident
after adopting TSTF-476 are no different than the consequences of an
accident prior to adopting TSTF-476. Therefore, the consequences of an
accident previously evaluated are not significantly affected by this
change. Therefore, this change does not involve a significant increase
in the probability or consequences of an accident previously evaluated.
Criterion 2--The Proposed Change Does Not Create the Possibility of a
New or Different Kind of Accident from any Previously Evaluated
The proposed change will not introduce new failure modes or effects
and will not, in the absence of other unrelated failures, lead to an
accident whose consequences exceed the consequences of accidents
previously evaluated. The control rod drop accident (CRDA) is the
design basis accident for the subject TS changes. This change does not
create the possibility of a new or different kind of accident from an
accident previously evaluated.
Criterion 3--The Proposed Change Does Not Involve a Significant
Reduction in the Margin of Safety
The proposed change, TSTF-476, Revision 1, incorporates the
improved BPWS, previously approved in NEDO-33091-A, into the improved
TS. The control rod drop accident (CRDA) is the design basis accident
for the subject TS changes. In order to minimize the impact of a CRDA,
the BPWS process was developed to minimize control rod reactivity worth
for BWR plants. The proposed improved BPWS further simplifies the
control rod insertion process, and in order to evaluate it, the staff
followed the guidelines of Standard Review Plan Section 15.4.9, and
referred to General Design Criterion 28 of
[[Page 29010]]
Appendix A to 10 CFR Part 50 as its regulatory requirement. The TSTF
stated the improved BPWS provides the following benefits: (1) Allows
the plant to reach the all-rods-in condition prior to significant
reactor cool down, which reduces the potential for re-criticality as
the reactor cools down; (2) reduces the potential for an operator
reactivity control error by reducing the total number of control rod
manipulations; (3) minimizes the need for manual scrams during plant
shutdowns, resulting in less wear on control rod drive (CRD) system
components and CRD mechanisms; and (4) eliminates unnecessary control
rod manipulations at low power, resulting in less wear on reactor
manual control and CRD system components. The addition of procedural
requirements and verifications specified in NEDO-33091-A, along with
the proper use of the BPWS will prevent a control rod drop accident
(CRDA) from occurring while power is below the low power setpoint
(LPSP). The net change to the margin of safety is insignificant.
Therefore, this change does not involve a significant reduction in a
margin of safety.
Based upon the above discussion of the amendment request, the
requested change does not involve a significant hazards consideration.
Dated at Rockville, Maryland, this 10th day of May 2007.
For the Nuclear Regulatory Commission.
Timothy J. Kobetz,
Branch Chief, Technical Specifications Branch, Division of Inspection
& Regional Support, Office of Nuclear Reactor Regulation.
[FR Doc. 07-2563 Filed 5-22-07; 8:45 am]