Airworthiness Directives; McDonnell Douglas Model DC-9-81 (MD-81), DC-9-82 (MD-82), DC-9-83 (MD-83), DC-9-87 (MD-87), and MD-88 Airplanes, 28626-28628 [E6-7479]

Download as PDF 28626 Federal Register / Vol. 71, No. 95 / Wednesday, May 17, 2006 / Proposed Rules are acceptable for compliance with the corresponding requirements of this AD. Alternative Methods of Compliance (AMOCs) (j)(1) The Manager, Los Angeles ACO, FAA, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19. (2) Before using any AMOC approved in accordance with § 39.19 on any airplane to which the AMOC applies, notify the appropriate principal inspector in the FAA Flight Standards Certificate Holding District Office. Issued in Renton, Washington, on May 9, 2006. Ali Bahrami, Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. E6–7475 Filed 5–16–06; 8:45 am] BILLING CODE 4910–13–P DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Part 39 [Docket No. FAA–2006–24786; Directorate Identifier 2006–NM–087–AD] RIN 2120–AA64 Airworthiness Directives; McDonnell Douglas Model DC–9–81 (MD–81), DC– 9–82 (MD–82), DC–9–83 (MD–83), DC– 9–87 (MD–87), and MD–88 Airplanes Federal Aviation Administration (FAA), Department of Transportation (DOT). ACTION: Notice of proposed rulemaking (NPRM). mstockstill on PROD1PC61 with PROPOSALS AGENCY: SUMMARY: The FAA proposes to adopt a new airworthiness directive (AD) for certain McDonnell Douglas Model DC– 9–81 (MD–81), DC–9–82 (MD–82), DC– 9–83 (MD–83), DC–9–87 (MD–87), and MD–88 airplanes. This proposed AD would require installing a clamp, a bonding jumper assembly, and attaching hardware to the refueling manifold in the right wing refueling station area. This proposed AD results from fuel system reviews conducted by the manufacturer. We are proposing this AD to prevent arcing on the in-tank side of the fueling valve during a lightning strike, which could result in an ignition source that could ignite fuel vapor and cause a fuel tank explosion. DATES: We must receive comments on this proposed AD by July 3, 2006. ADDRESSES: Use one of the following addresses to submit comments on this proposed AD. • DOT Docket Web site: Go to https://dms.dot.gov and follow the VerDate Aug<31>2005 15:07 May 16, 2006 Jkt 208001 instructions for sending your comments electronically. • Government-wide rulemaking Web site: Go to https://www.regulations.gov and follow the instructions for sending your comments electronically. • Mail: Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., Nassif Building, room PL–401, Washington, DC 20590. • Fax: (202) 493–2251. • Hand Delivery: Room PL–401 on the plaza level of the Nassif Building, 400 Seventh Street, SW., Washington, DC, between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. Contact Boeing Commercial Airplanes, Long Beach Division, 3855 Lakewood Boulevard, Long Beach, California 90846, Attention: Data and Service Management, Dept. C1–L5A (D800–0024), for the service information identified in this proposed AD. FOR FURTHER INFORMATION CONTACT: William Bond, Aerospace Engineer, Propulsion Branch, ANM–140L, FAA, Los Angeles Aircraft Certification Office, 3960 Paramount Boulevard, Lakewood, California 90712–4137; telephone (562) 627–5253; fax (562) 627–5210. SUPPLEMENTARY INFORMATION: Comments Invited We invite you to submit any relevant written data, views, or arguments regarding this proposed AD. Send your comments to an address listed in the ADDRESSES section. Include the docket number ‘‘FAA–2006–24786; Directorate Identifier 2006–NM–087–AD’’ at the beginning of your comments. We specifically invite comments on the overall regulatory, economic, environmental, and energy aspects of the proposed AD. We will consider all comments received by the closing date and may amend the proposed AD in light of those comments. We will post all comments we receive, without change, to https:// dms.dot.gov, including any personal information you provide. We will also post a report summarizing each substantive verbal contact with FAA personnel concerning this proposed AD. Using the search function of that web site, anyone can find and read the comments in any of our dockets, including the name of the individual who sent the comment (or signed the comment on behalf of an association, business, labor union, etc.). You may review DOT’s complete Privacy Act Statement in the Federal Register published on April 11, 2000 (65 FR 19477–78), or you may visit https:// dms.dot.gov. PO 00000 Frm 00037 Fmt 4702 Sfmt 4702 Examining the Docket You may examine the AD docket on the Internet at https://dms.dot.gov, or in person at the Docket Management Facility office between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. The Docket Management Facility office (telephone (800) 647–5227) is located on the plaza level of the Nassif Building at the DOT street address stated in the ADDRESSES section. Comments will be available in the AD docket shortly after the Docket Management System receives them. Discussion The FAA has examined the underlying safety issues involved in fuel tank explosions on several large transport airplanes, including the adequacy of existing regulations, the service history of airplanes subject to those regulations, and existing maintenance practices for fuel tank systems. As a result of those findings, we issued a regulation titled ‘‘Transport Airplane Fuel Tank System Design Review, Flammability Reduction and Maintenance and Inspection Requirements’’ (67 FR 23086, May 7, 2001). In addition to new airworthiness standards for transport airplanes and new maintenance requirements, this rule included Special Federal Aviation Regulation No. 88 (‘‘SFAR 88,’’ Amendment 21–78, and subsequent Amendments 21–82 and 21–83). Among other actions, SFAR 88 requires certain type design (i.e., type certificate (TC) and supplemental type certificate (STC)) holders to substantiate that their fuel tank systems can prevent ignition sources in the fuel tanks. This requirement applies to type design holders for large turbine-powered transport airplanes and for subsequent modifications to those airplanes. It requires them to perform design reviews and to develop design changes and maintenance procedures if their designs do not meet the new fuel tank safety standards. As explained in the preamble to the rule, we intended to adopt airworthiness directives to mandate any changes found necessary to address unsafe conditions identified as a result of these reviews. In evaluating these design reviews, we have established four criteria intended to define the unsafe conditions associated with fuel tank systems that require corrective actions. The percentage of operating time during which fuel tanks are exposed to flammable conditions is one of these criteria. The other three criteria address the failure types under evaluation: single failures, single failures in E:\FR\FM\17MYP1.SGM 17MYP1 Federal Register / Vol. 71, No. 95 / Wednesday, May 17, 2006 / Proposed Rules combination with a latent condition(s), and in-service failure experience. For all four criteria, the evaluations included consideration of previous actions taken that may mitigate the need for further action. We have determined that the actions identified in this AD are necessary to reduce the potential of ignition sources inside fuel tanks, which, in combination with flammable fuel vapors, could result in fuel tank explosions and consequent loss of the airplane. We have received a report indicating that a SFAR 88 review of the fuel system on McDonnell Douglas Model MD–80 airplanes revealed a potential for arcing on the in-tank side of the fueling valve during a lightning strike. The nonconductive coating, which keeps the rigid pipes and valves electrically isolated, may wear off or be scratched. Any wear or scratch in the coating could allow lightning-induced current to flow from the refueling manifold to the airplane structure through the fueling valve and could cause arcing. Arcing on the in-tank side of the fueling valve could result in an ignition source that could ignite fuel vapor and cause a fuel tank explosion. Relevant Service Information We have reviewed Boeing Service Bulletin MD80–28–213, dated May 16, 2005. The service bulletin describes procedures for installing a clamp, a bonding jumper assembly, and attaching hardware to the refueling manifold in the right wing refueling station area. Accomplishing the actions specified in the service information is intended to adequately address the unsafe condition. FAA’s Determination and Requirements of the Proposed AD We have evaluated all pertinent information and identified an unsafe condition that is likely to exist or develop on other airplanes of this same type design. For this reason, we are proposing this AD, which would require accomplishing the actions specified in the service information described previously. mstockstill on PROD1PC61 with PROPOSALS Costs of Compliance There are about 994 airplanes of the affected design in the worldwide fleet. This proposed AD would affect about 573 airplanes of U.S. registry. The proposed actions would take about 2 work hours per airplane, at an average labor rate of $80 per work hour. Required parts would cost about $8 per airplane. Based on these figures, the estimated cost of the proposed AD for VerDate Aug<31>2005 15:07 May 16, 2006 Jkt 208001 U.S. operators is $96,264, or $168 per airplane. Authority for This Rulemaking Title 49 of the United States Code specifies the FAA’s authority to issue rules on aviation safety. Subtitle I, Section 106, describes the authority of the FAA Administrator. Subtitle VII, Aviation Programs, describes in more detail the scope of the Agency’s authority. We are issuing this rulemaking under the authority described in Subtitle VII, Part A, Subpart III, Section 44701, ‘‘General requirements.’’ Under that section, Congress charges the FAA with promoting safe flight of civil aircraft in air commerce by prescribing regulations for practices, methods, and procedures the Administrator finds necessary for safety in air commerce. This regulation is within the scope of that authority because it addresses an unsafe condition that is likely to exist or develop on products identified in this rulemaking action. Regulatory Findings We have determined that this proposed AD would not have federalism implications under Executive Order 13132. This proposed AD would not have a substantial direct effect on the States, on the relationship between the national Government and the States, or on the distribution of power and responsibilities among the various levels of government. For the reasons discussed above, I certify that the proposed regulation: 1. Is not a ‘‘significant regulatory action’’ under Executive Order 12866; 2. Is not a ‘‘significant rule’’ under the DOT Regulatory Policies and Procedures (44 FR 11034, February 26, 1979); and 3. Will not have a significant economic impact, positive or negative, on a substantial number of small entities under the criteria of the Regulatory Flexibility Act. We prepared a regulatory evaluation of the estimated costs to comply with this proposed AD and placed it in the AD docket. See the ADDRESSES section for a location to examine the regulatory evaluation. List of Subjects in 14 CFR Part 39 Air transportation, Aircraft, Aviation safety, Safety. The Proposed Amendment Accordingly, under the authority delegated to me by the Administrator, the FAA proposes to amend 14 CFR part 39 as follows: PO 00000 Frm 00038 Fmt 4702 Sfmt 4702 28627 PART 39—AIRWORTHINESS DIRECTIVES 1. The authority citation for part 39 continues to read as follows: Authority: 49 U.S.C. 106(g), 40113, 44701. § 39.13 [Amended] 2. The Federal Aviation Administration (FAA) amends § 39.13 by adding the following new airworthiness directive (AD): McDonnell Douglas: Docket No. FAA–2006– 24786; Directorate Identifier 2006–NM– 087–AD. Comments Due Date (a) The FAA must receive comments on this AD action by July 3, 2006. Affected ADs (b) None. Applicability (c) This AD applies to McDonnell Douglas Model DC–9–81 (MD–81), DC–9–82 (MD–82), DC–9–83 (MD–83), DC–9–87 (MD–87), and MD–88 airplanes, certificated in any category; as identified in Boeing Service Bulletin MD80–28–213, dated May 16, 2005. Unsafe Condition (d) This AD results from fuel system reviews conducted by the manufacturer. We are issuing this AD to prevent arcing on the in-tank side of the fueling valve during a lightning strike, which could result in an ignition source that could ignite fuel vapor and cause a fuel tank explosion. Compliance (e) You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done. Electrical Bond Installation (f) Within 60 months after the effective date of this AD, install a clamp, a bonding jumper assembly, and attaching hardware to the refueling manifold in the right wing refueling station area; in accordance with the Accomplishment Instructions of Boeing Service Bulletin MD80–28–213, dated May 16, 2005. Alternative Methods of Compliance (AMOCs) (g)(1) The Manager, Los Angeles Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19. (2) Before using any AMOC approved in accordance with § 39.19 on any airplane to which the AMOC applies, notify the appropriate principal inspector in the FAA Flight Standards Certificate Holding District Office. E:\FR\FM\17MYP1.SGM 17MYP1 28628 Federal Register / Vol. 71, No. 95 / Wednesday, May 17, 2006 / Proposed Rules Issued in Renton, Washington, on May 9, 2006. Ali Bahrami, Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. E6–7479 Filed 5–16–06; 8:45 am] BILLING CODE 4910–13–P DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Part 39 [Docket No. FAA–2006–24788; Directorate Identifier 2006–NM–073–AD] DC, between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. Contact Empresa Brasileira de Aeronautica S.A. (EMBRAER), P.O. Box 343—CEP 12.225, Sao Jose dos Campos—SP, Brazil, for service information identified in this proposed AD. FOR FURTHER INFORMATION CONTACT: Todd Thompson, Aerospace Engineer, International Branch, ANM–116, Transport Airplane Directorate, FAA, 1601 Lind Avenue, SW., Renton, Washington 98055–4056; telephone (425) 227–1175; fax (425) 227–1149. SUPPLEMENTARY INFORMATION: RIN 2120–AA64 Comments Invited Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 Airplanes Federal Aviation Administration (FAA), Department of Transportation (DOT). ACTION: Notice of proposed rulemaking (NPRM). mstockstill on PROD1PC61 with PROPOSALS AGENCY: SUMMARY: The FAA proposes to adopt a new airworthiness directive (AD) for certain EMBRAER Model ERJ 170 airplanes. This proposed AD would require a one-time inspection for proper crimping of the terminal lugs for the power cables of each integrated drive generator (IDG), installing a new sleeve on the terminal, and re-crimping if necessary. This proposed AD results from a report that the terminal lugs for the power cables of the IDGs may not be adequately crimped, which could allow the cables to be pulled out of the terminals with no significant force. We are proposing this AD to prevent loss of all normal electrical power for the airplane, and consequent reduced controllability of the airplane. DATES: We must receive comments on this proposed AD by June 16, 2006. ADDRESSES: Use one of the following addresses to submit comments on this proposed AD. • DOT Docket Web site: Go to https://dms.dot.gov and follow the instructions for sending your comments electronically. • Government-wide rulemaking Web site: Go to https://www.regulations.gov and follow the instructions for sending your comments electronically. • Mail: Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., Nassif Building, room PL–401, Washington, DC 20590. • Fax: (202) 493–2251. • Hand Delivery: Room PL–401 on the plaza level of the Nassif Building, 400 Seventh Street, SW., Washington, VerDate Aug<31>2005 15:07 May 16, 2006 Jkt 208001 We invite you to submit any relevant written data, views, or arguments regarding this proposed AD. Send your comments to an address listed in the ADDRESSES section. Include the docket number ‘‘FAA–2006–24788; Directorate Identifier 2006–NM–073–AD’’ at the beginning of your comments. We specifically invite comments on the overall regulatory, economic, environmental, and energy aspects of the proposed AD. We will consider all comments received by the closing date and may amend the proposed AD in light of those comments. We will post all comments we receive, without change, to https:// dms.dot.gov, including any personal information you provide. We will also post a report summarizing each substantive verbal contact with FAA personnel concerning this proposed AD. Using the search function of that Web site, anyone can find and read the comments in any of our dockets, including the name of the individual who sent the comment (or signed the comment on behalf of an association, business, labor union, etc.). You may review the DOT’s complete Privacy Act Statement in the Federal Register published on April 11, 2000 (65 FR 19477–78), or you may visit https:// dms.dot.gov. Examining the Docket You may examine the AD docket on the Internet at https://dms.dot.gov, or in person at the Docket Management Facility office between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. The Docket Management Facility office (telephone (800) 647–5227) is located on the plaza level of the Nassif Building at the DOT street address stated in the ADDRESSES section. Comments will be available in the AD docket shortly after the Docket Management System receives them. PO 00000 Frm 00039 Fmt 4702 Sfmt 4702 Discussion The Departamento de Aviacao Civil ¸˜ (DAC), which is the airworthiness authority for Brazil, notified us that an unsafe condition may exist on certain EMBRAER Model ERJ 170 airplanes. The DAC advises that during a heavy maintenance action, it was discovered that four terminal lugs for the power cables of the integrated drive generators (IDGs) were not adequately crimped during installation, which could allow the cables to be pulled out of the terminals with no significant force. This condition, if not corrected, could result in loss of all normal electrical power for the airplane, and consequent reduced controllability of the airplane. Relevant Service Information EMBRAER has issued Service Bulletin 170–24–0028, dated January 4, 2006. The service bulletin describes procedures for doing an inspection of the crimping of terminal lugs for the power cables of each IDG, and corrective actions. The corrective actions are installing a new sleeve on the terminal, and re-crimping if necessary. Accomplishing the actions specified in the service information is intended to adequately address the unsafe condition. The DAC mandated the service information and issued Brazilian airworthiness directive 2006– 02–04, dated March 15, 2006, to ensure the continued airworthiness of these airplanes in Brazil. FAA’s Determination and Requirements of the Proposed AD This airplane model is manufactured in Brazil and is type certificated for operation in the United States under the provisions of section 21.29 of the Federal Aviation Regulations (14 CFR 21.29) and the applicable bilateral airworthiness agreement. Pursuant to this bilateral airworthiness agreement, the DAC has kept the FAA informed of the situation described above. We have examined the DAC’s findings, evaluated all pertinent information, and determined that we need to issue an AD for airplanes of this type design that are certificated for operation in the United States. Therefore, we are proposing this AD, which would require accomplishing the actions specified in the service information described previously. Clarification of Inspection Terminology In this proposed AD, the ‘‘detailed visual inspection’’ specified in the Brazilian airworthiness directive is referred to as a ‘‘detailed inspection.’’ We have included the definition for a E:\FR\FM\17MYP1.SGM 17MYP1

Agencies

[Federal Register Volume 71, Number 95 (Wednesday, May 17, 2006)]
[Proposed Rules]
[Pages 28626-28628]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: E6-7479]


-----------------------------------------------------------------------

DEPARTMENT OF TRANSPORTATION

Federal Aviation Administration

14 CFR Part 39

[Docket No. FAA-2006-24786; Directorate Identifier 2006-NM-087-AD]
RIN 2120-AA64


Airworthiness Directives; McDonnell Douglas Model DC-9-81 (MD-
81), DC-9-82 (MD-82), DC-9-83 (MD-83), DC-9-87 (MD-87), and MD-88 
Airplanes

AGENCY: Federal Aviation Administration (FAA), Department of 
Transportation (DOT).

ACTION: Notice of proposed rulemaking (NPRM).

-----------------------------------------------------------------------

SUMMARY: The FAA proposes to adopt a new airworthiness directive (AD) 
for certain McDonnell Douglas Model DC-9-81 (MD-81), DC-9-82 (MD-82), 
DC-9-83 (MD-83), DC-9-87 (MD-87), and MD-88 airplanes. This proposed AD 
would require installing a clamp, a bonding jumper assembly, and 
attaching hardware to the refueling manifold in the right wing 
refueling station area. This proposed AD results from fuel system 
reviews conducted by the manufacturer. We are proposing this AD to 
prevent arcing on the in-tank side of the fueling valve during a 
lightning strike, which could result in an ignition source that could 
ignite fuel vapor and cause a fuel tank explosion.

DATES: We must receive comments on this proposed AD by July 3, 2006.

ADDRESSES: Use one of the following addresses to submit comments on 
this proposed AD.
     DOT Docket Web site: Go to https://dms.dot.gov and follow 
the instructions for sending your comments electronically.
     Government-wide rulemaking Web site: Go to https://
www.regulations.gov and follow the instructions for sending your 
comments electronically.
     Mail: Docket Management Facility, U.S. Department of 
Transportation, 400 Seventh Street, SW., Nassif Building, room PL-401, 
Washington, DC 20590.
     Fax: (202) 493-2251.
     Hand Delivery: Room PL-401 on the plaza level of the 
Nassif Building, 400 Seventh Street, SW., Washington, DC, between 9 
a.m. and 5 p.m., Monday through Friday, except Federal holidays.
    Contact Boeing Commercial Airplanes, Long Beach Division, 3855 
Lakewood Boulevard, Long Beach, California 90846, Attention: Data and 
Service Management, Dept. C1-L5A (D800-0024), for the service 
information identified in this proposed AD.

FOR FURTHER INFORMATION CONTACT: William Bond, Aerospace Engineer, 
Propulsion Branch, ANM-140L, FAA, Los Angeles Aircraft Certification 
Office, 3960 Paramount Boulevard, Lakewood, California 90712-4137; 
telephone (562) 627-5253; fax (562) 627-5210.

SUPPLEMENTARY INFORMATION:

Comments Invited

    We invite you to submit any relevant written data, views, or 
arguments regarding this proposed AD. Send your comments to an address 
listed in the ADDRESSES section. Include the docket number ``FAA-2006-
24786; Directorate Identifier 2006-NM-087-AD'' at the beginning of your 
comments. We specifically invite comments on the overall regulatory, 
economic, environmental, and energy aspects of the proposed AD. We will 
consider all comments received by the closing date and may amend the 
proposed AD in light of those comments.
    We will post all comments we receive, without change, to https://
dms.dot.gov, including any personal information you provide. We will 
also post a report summarizing each substantive verbal contact with FAA 
personnel concerning this proposed AD. Using the search function of 
that web site, anyone can find and read the comments in any of our 
dockets, including the name of the individual who sent the comment (or 
signed the comment on behalf of an association, business, labor union, 
etc.). You may review DOT's complete Privacy Act Statement in the 
Federal Register published on April 11, 2000 (65 FR 19477-78), or you 
may visit https://dms.dot.gov.

Examining the Docket

    You may examine the AD docket on the Internet at https://
dms.dot.gov, or in person at the Docket Management Facility office 
between 9 a.m. and 5 p.m., Monday through Friday, except Federal 
holidays. The Docket Management Facility office (telephone (800) 647-
5227) is located on the plaza level of the Nassif Building at the DOT 
street address stated in the ADDRESSES section. Comments will be 
available in the AD docket shortly after the Docket Management System 
receives them.

Discussion

    The FAA has examined the underlying safety issues involved in fuel 
tank explosions on several large transport airplanes, including the 
adequacy of existing regulations, the service history of airplanes 
subject to those regulations, and existing maintenance practices for 
fuel tank systems. As a result of those findings, we issued a 
regulation titled ``Transport Airplane Fuel Tank System Design Review, 
Flammability Reduction and Maintenance and Inspection Requirements'' 
(67 FR 23086, May 7, 2001). In addition to new airworthiness standards 
for transport airplanes and new maintenance requirements, this rule 
included Special Federal Aviation Regulation No. 88 (``SFAR 88,'' 
Amendment 21-78, and subsequent Amendments 21-82 and 21-83).
    Among other actions, SFAR 88 requires certain type design (i.e., 
type certificate (TC) and supplemental type certificate (STC)) holders 
to substantiate that their fuel tank systems can prevent ignition 
sources in the fuel tanks. This requirement applies to type design 
holders for large turbine-powered transport airplanes and for 
subsequent modifications to those airplanes. It requires them to 
perform design reviews and to develop design changes and maintenance 
procedures if their designs do not meet the new fuel tank safety 
standards. As explained in the preamble to the rule, we intended to 
adopt airworthiness directives to mandate any changes found necessary 
to address unsafe conditions identified as a result of these reviews.
    In evaluating these design reviews, we have established four 
criteria intended to define the unsafe conditions associated with fuel 
tank systems that require corrective actions. The percentage of 
operating time during which fuel tanks are exposed to flammable 
conditions is one of these criteria. The other three criteria address 
the failure types under evaluation: single failures, single failures in

[[Page 28627]]

combination with a latent condition(s), and in-service failure 
experience. For all four criteria, the evaluations included 
consideration of previous actions taken that may mitigate the need for 
further action.
    We have determined that the actions identified in this AD are 
necessary to reduce the potential of ignition sources inside fuel 
tanks, which, in combination with flammable fuel vapors, could result 
in fuel tank explosions and consequent loss of the airplane.
    We have received a report indicating that a SFAR 88 review of the 
fuel system on McDonnell Douglas Model MD-80 airplanes revealed a 
potential for arcing on the in-tank side of the fueling valve during a 
lightning strike. The non-conductive coating, which keeps the rigid 
pipes and valves electrically isolated, may wear off or be scratched. 
Any wear or scratch in the coating could allow lightning-induced 
current to flow from the refueling manifold to the airplane structure 
through the fueling valve and could cause arcing. Arcing on the in-tank 
side of the fueling valve could result in an ignition source that could 
ignite fuel vapor and cause a fuel tank explosion.

Relevant Service Information

    We have reviewed Boeing Service Bulletin MD80-28-213, dated May 16, 
2005. The service bulletin describes procedures for installing a clamp, 
a bonding jumper assembly, and attaching hardware to the refueling 
manifold in the right wing refueling station area. Accomplishing the 
actions specified in the service information is intended to adequately 
address the unsafe condition.

FAA's Determination and Requirements of the Proposed AD

    We have evaluated all pertinent information and identified an 
unsafe condition that is likely to exist or develop on other airplanes 
of this same type design. For this reason, we are proposing this AD, 
which would require accomplishing the actions specified in the service 
information described previously.

Costs of Compliance

    There are about 994 airplanes of the affected design in the 
worldwide fleet. This proposed AD would affect about 573 airplanes of 
U.S. registry. The proposed actions would take about 2 work hours per 
airplane, at an average labor rate of $80 per work hour. Required parts 
would cost about $8 per airplane. Based on these figures, the estimated 
cost of the proposed AD for U.S. operators is $96,264, or $168 per 
airplane.

Authority for This Rulemaking

    Title 49 of the United States Code specifies the FAA's authority to 
issue rules on aviation safety. Subtitle I, Section 106, describes the 
authority of the FAA Administrator. Subtitle VII, Aviation Programs, 
describes in more detail the scope of the Agency's authority.
    We are issuing this rulemaking under the authority described in 
Subtitle VII, Part A, Subpart III, Section 44701, ``General 
requirements.'' Under that section, Congress charges the FAA with 
promoting safe flight of civil aircraft in air commerce by prescribing 
regulations for practices, methods, and procedures the Administrator 
finds necessary for safety in air commerce. This regulation is within 
the scope of that authority because it addresses an unsafe condition 
that is likely to exist or develop on products identified in this 
rulemaking action.

Regulatory Findings

    We have determined that this proposed AD would not have federalism 
implications under Executive Order 13132. This proposed AD would not 
have a substantial direct effect on the States, on the relationship 
between the national Government and the States, or on the distribution 
of power and responsibilities among the various levels of government.
    For the reasons discussed above, I certify that the proposed 
regulation:
    1. Is not a ``significant regulatory action'' under Executive Order 
12866;
    2. Is not a ``significant rule'' under the DOT Regulatory Policies 
and Procedures (44 FR 11034, February 26, 1979); and
    3. Will not have a significant economic impact, positive or 
negative, on a substantial number of small entities under the criteria 
of the Regulatory Flexibility Act.
    We prepared a regulatory evaluation of the estimated costs to 
comply with this proposed AD and placed it in the AD docket. See the 
ADDRESSES section for a location to examine the regulatory evaluation.

List of Subjects in 14 CFR Part 39

    Air transportation, Aircraft, Aviation safety, Safety.

The Proposed Amendment

    Accordingly, under the authority delegated to me by the 
Administrator, the FAA proposes to amend 14 CFR part 39 as follows:

PART 39--AIRWORTHINESS DIRECTIVES

    1. The authority citation for part 39 continues to read as follows:

    Authority: 49 U.S.C. 106(g), 40113, 44701.

Sec.  39.13  [Amended]

    2. The Federal Aviation Administration (FAA) amends Sec.  39.13 by 
adding the following new airworthiness directive (AD):

McDonnell Douglas: Docket No. FAA-2006-24786; Directorate Identifier 
2006-NM-087-AD.

Comments Due Date

    (a) The FAA must receive comments on this AD action by July 3, 
2006.

Affected ADs

    (b) None.

Applicability

    (c) This AD applies to McDonnell Douglas Model DC-9-81 (MD-81), 
DC-9-82 (MD-82), DC-9-83 (MD-83), DC-9-87 (MD-87), and MD-88 
airplanes, certificated in any category; as identified in Boeing 
Service Bulletin MD80-28-213, dated May 16, 2005.

Unsafe Condition

    (d) This AD results from fuel system reviews conducted by the 
manufacturer. We are issuing this AD to prevent arcing on the in-
tank side of the fueling valve during a lightning strike, which 
could result in an ignition source that could ignite fuel vapor and 
cause a fuel tank explosion.

Compliance

    (e) You are responsible for having the actions required by this 
AD performed within the compliance times specified, unless the 
actions have already been done.

Electrical Bond Installation

    (f) Within 60 months after the effective date of this AD, 
install a clamp, a bonding jumper assembly, and attaching hardware 
to the refueling manifold in the right wing refueling station area; 
in accordance with the Accomplishment Instructions of Boeing Service 
Bulletin MD80-28-213, dated May 16, 2005.

Alternative Methods of Compliance (AMOCs)

    (g)(1) The Manager, Los Angeles Aircraft Certification Office 
(ACO), FAA, has the authority to approve AMOCs for this AD, if 
requested in accordance with the procedures found in 14 CFR 39.19.
    (2) Before using any AMOC approved in accordance with Sec.  
39.19 on any airplane to which the AMOC applies, notify the 
appropriate principal inspector in the FAA Flight Standards 
Certificate Holding District Office.


[[Page 28628]]


    Issued in Renton, Washington, on May 9, 2006.
Ali Bahrami,
Manager, Transport Airplane Directorate, Aircraft Certification 
Service.
 [FR Doc. E6-7479 Filed 5-16-06; 8:45 am]
BILLING CODE 4910-13-P