Energy Conservation Standards for Certain Consumer Products and Commercial and Industrial Equipment, 61698 [C5-20701]
Download as PDF
61698
Corrections
Federal Register
Vol. 70, No. 205
Tuesday, October 25, 2005
This section of the FEDERAL REGISTER
contains editorial corrections of previously
published Presidential, Rule, Proposed Rule,
and Notice documents. These corrections are
prepared by the Office of the Federal
Register. Agency prepared corrections are
issued as signed documents and appear in
the appropriate document categories
elsewhere in the issue.
October 18, 2005, make the following
corrections:
§ 430.32
[Corrected]
1. On page 60413, in §430.32(u), in
the second table, under the first column,
in the 12th line, ‘‘Lamp Power>20’’
should read ‘‘Lamp Power≥20’’.
§ 431.97
[Corrected]
Energy Conservation Standards for
Certain Consumer Products and
Commercial and Industrial Equipment
2. On page 60415, in §431.97(b), in
the table, in the fourth column, the
heading ‘‘Efficiency level’’ should read
‘‘Efficiency level†’’.
3. On the same page, in the same
section, in the same table, in the same
column, in the fifth entry, ‘‘EER = 1
1.0*’’ should read ‘‘EER = 11.0*’’.
4. On the same page, in the same
section, in the same table, in the third
footnote, ‘‘*EER’’ should read ‘‘†EER’’.
Correction
§ 431.136
In rule document 05–20701 beginning
on page 60407 in the issue of Tuesday,
5. On page 60416, in §431.136, the
table is corrected to read as follows:
DEPARTMENT OF ENERGY
Office of Energy Efficiency and
Renewable Energy
10 CFR Parts 430 and 431
RIN 1904–AB54
[Corrected]
Maximum energy use
(kWh/100 lbs
ice)
Maximum condenser water
use *
(gal/100 lbs ice)
200–0.022H.
200–0.022H.
200–0.022H.
Not applicable.
≥450 ..............................................
<1000 ............................................
7.80–0.0055H
5.58–0.0011H
4.0 ..................
10.26–
0.0086H.
6.89–0.0011H
8.85–0.0038H
Air ..................................................
≥1000 ............................................
5.1 ..................
Not applicable.
Air ..................................................
<934 ..............................................
8.85–0.0038H
Not applicable.
Air ..................................................
≥934 ..............................................
5.3 ..................
Not applicable.
Water .............................................
Water .............................................
Air ..................................................
Air ..................................................
<200
≥200
<175
≥175
11. 40–0.019H
7.6 ..................
18.0–0.0469H
9.8 ..................
191–0.0315H.
191–0.0315H.
Not applicable.
Not applicable.
Type of cooling
Harvest rate
(lbs ice/24 hours)
...........................
...........................
...........................
...........................
Water .............................................
Water .............................................
Water .............................................
Air ..................................................
<500 ..............................................
≥500 and <1436 ............................
≥1436 ............................................
<450 ..............................................
Ice Making Head ...........................
Remote Condensing (but not remote compressor).
Remote Condensing (but not remote compressor).
Remote Condensing and Remote
Compressor.
Remote Condensing and Remote
Compressor.
Self Contained ..............................
Self Contained ..............................
Self Contained ..............................
Self Contained ..............................
Air ..................................................
Air ..................................................
Equipment type
Ice
Ice
Ice
Ice
Making
Making
Making
Making
Head
Head
Head
Head
..............................................
..............................................
..............................................
..............................................
H Harvest rate in pounds per 24 hours.
* Water use is for the condenser only and does not include potable water used to make ice.
[FR Doc. C5–20701 Filed 10–24–05; 8:45 am]
BILLING CODE 1505–01–D
VerDate Aug<31>2005
15:56 Oct 24, 2005
Jkt 208001
PO 00000
Frm 00001
Fmt 4734
Sfmt 4734
E:\FR\FM\25OCCX.SGM
25OCCX
Not applicable.
Not applicable.
Agencies
[Federal Register Volume 70, Number 205 (Tuesday, October 25, 2005)]
[Corrections]
[Page 61698]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: C5-20701]
Federal Register / Vol. 70, No. 205 / Tuesday, October 25, 2005 /
CORRECTIONS
[[Page 61698]]
DEPARTMENT OF ENERGY
Office of Energy Efficiency and Renewable Energy
10 CFR Parts 430 and 431
RIN 1904-AB54
Energy Conservation Standards for Certain Consumer Products and
Commercial and Industrial Equipment
Correction
In rule document 05-20701 beginning on page 60407 in the issue of
Tuesday, October 18, 2005, make the following corrections:
Sec. 430.32 [Corrected]
1. On page 60413, in Sec. 430.32(u), in the second table, under the
first column, in the 12th line, ``Lamp Power>20'' should read ``Lamp
Power>=20''.
Sec. 431.97 [Corrected]
2. On page 60415, in Sec. 431.97(b), in the table, in the fourth
column, the heading ``Efficiency level'' should read ``Efficiency
level[dagger]''.
3. On the same page, in the same section, in the same table, in the
same column, in the fifth entry, ``EER = 1 1.0*'' should read ``EER =
11.0*''.
4. On the same page, in the same section, in the same table, in the
third footnote, ``*EER'' should read ``[dagger]EER''.
Sec. 431.136 [Corrected]
5. On page 60416, in Sec. 431.136, the table is corrected to read
as follows:
----------------------------------------------------------------------------------------------------------------
Harvest rate Maximum condenser
Equipment type Type of cooling (lbs ice/24 Maximum energy use water use * (gal/100
hours) (kWh/100 lbs ice) lbs ice)
----------------------------------------------------------------------------------------------------------------
Ice Making Head............... Water............ <500............. 7.80-0.0055H....... 200-0.022H.
Ice Making Head............... Water............ >=500 and <1436.. 5.58-0.0011H....... 200-0.022H.
Ice Making Head............... Water............ >=1436........... 4.0................ 200-0.022H.
Ice Making Head............... Air.............. <450............. 10.26-0.0086H...... Not applicable.
Ice Making Head............... Air.............. >=450............ 6.89-0.0011H....... Not applicable.
Remote Condensing (but not Air.............. <1000............ 8.85-0.0038H....... Not applicable.
remote compressor).
Remote Condensing (but not Air.............. >=1000........... 5.1................ Not applicable.
remote compressor).
Remote Condensing and Remote Air.............. <934............. 8.85-0.0038H....... Not applicable.
Compressor.
Remote Condensing and Remote Air.............. >=934............ 5.3................ Not applicable.
Compressor.
Self Contained................ Water............ <200............. 11. 40-0.019H...... 191-0.0315H.
Self Contained................ Water............ >=200............ 7.6................ 191-0.0315H.
Self Contained................ Air.............. <175............. 18.0-0.0469H....... Not applicable.
Self Contained................ Air.............. >=175............ 9.8................ Not applicable.
----------------------------------------------------------------------------------------------------------------
H Harvest rate in pounds per 24 hours.
* Water use is for the condenser only and does not include potable water used to make ice.
[FR Doc. C5-20701 Filed 10-24-05; 8:45 am]
BILLING CODE 1505-01-D